Digital holographic inspection system for the inner surface of a straight pipe

被引:19
|
作者
Yokota, Masayuki [1 ]
Koyama, Teppei [1 ]
Takeda, Kazufumi [1 ]
机构
[1] Shimane Univ, Interdisciplinary Fac Sci & Engn, 1060 Nishikawatsu Cho, Matsue, Shimane 6908504, Japan
关键词
Digital holographic system; Holographic interferometry; Multiwavelength; Pipe inspection;
D O I
10.1016/j.optlaseng.2017.05.012
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A multicolor digital holographic inspection system achieving both automatic scanning sensing head and automatic correction of a distortion in the profile due to positional error of a sensing head has been applied to the inner surface of a straight brass pipe having artificial defects on its wall. To investigate the inner surface of the pipe, the sensing head consisting of a cone-shaped mirror (CSM) glued to an aluminum base in the pipe is illuminated by the collimated RGB laser beams from the outside of the pipe. In the system, by changing the wavelength of the illumination light and scanning the CSM in the pipe, data acquisitions and analysis are performed using a personal computer. It is shown that the pipe inspection, including a classification of defects, can be successfully conducted by comparing the multicolor intensity images and the height profile of inner surface of pipe. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:62 / 70
页数:9
相关论文
共 50 条
  • [1] Digital holographic inspection for a straight pipe inner surface using multiwavelength illuminations
    Yokota, Masayuki
    INTERNATIONAL SYMPOSIUM ON OPTOELECTRONIC TECHNOLOGY AND APPLICATION 2014: LASER AND OPTICAL MEASUREMENT TECHNOLOGY; AND FIBER OPTIC SENSORS, 2014, 9297
  • [2] Digital holographic inspection for the straight pipe inner surface using multiwavelength from laser diodes
    Yokota, M.
    Koyama, T.
    Kawakami, T.
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION VIII, 2013, 8788
  • [3] Digital holographic inspection for the inner surface of a straight pipe using current-induced multiwavelength from two laser diodes
    Yokota, Masayuki
    Koyama, Teppei
    Kawakami, Tomoaki
    OPTICAL ENGINEERING, 2014, 53 (10)
  • [4] Optical inspection system for the inner surface of a pipe
    Zhao Liefeng
    Feng Huajun
    Li Qi
    Ye Tingfeng
    ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL I, 2007, : 584 - 587
  • [5] Development of correction method for distortion due to both inclination and deviation of cone-shapcd mirror inside a pipe in digital holographic inspection system for a straight pipe
    Takeda K.
    Yokota M.
    1600, Japan Society for Precision Engineering (83): : 701 - 705
  • [6] INSPECTION OF DRILL PIPE THREADS FROM THE INNER SURFACE
    DAMASKIN, AL
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1991, 27 (03): : 179 - 183
  • [7] FATIGUE AND FRACTURE-BEHAVIOR OF STRAIGHT PIPE WITH FLAWS IN INNER SURFACE
    SHIBATA, K
    OBA, T
    KAWAMURA, T
    MIYAZONO, S
    YOKOYAMA, N
    NUCLEAR ENGINEERING AND DESIGN, 1981, 66 (01) : 33 - 45
  • [8] Digital holographic profilometry of the inner surface of a pipe using a current-induced wavelength change of a laser diode
    Yokota, Masayuki
    Adachi, Toru
    APPLIED OPTICS, 2011, 50 (21) : 3937 - 3946
  • [9] Nonaxiality of small-diameter pipe inner surface inspection sensor
    College of Mechanical Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
    不详
    Guangdianzi Jiguang, 2006, 4 (410-414):
  • [10] Non-contact laser inspection for the inner wall surface of a pipe
    Zhang, WW
    Zhuang, BH
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (09) : 1380 - 1387