CT of the abdomen: Degree and quality of enhancement obtained with two concentrations of the same iodinated contrast medium with fixed iodine delivery rate and total iodine load

被引:13
作者
Paparo, Francesco [1 ]
Garello, Isabella [1 ]
Bacigalupo, Lorenzo [1 ]
Marziano, Andrea [1 ]
Pregliasco, Athena Galletto [1 ]
Rollandi, Ludovica [2 ]
Puppo, Cristina [1 ]
Mattioli, Francesca [3 ]
Puntoni, Matteo [4 ]
Rollandi, Gian Andrea [1 ]
机构
[1] EO Osped Galliera, Dept Diagnost Imaging, Radiol Unit, Genoa, Italy
[2] Univ Genoa, Sch Med, Genoa, Italy
[3] Univ Genoa, Dept Internal Med, Pharmacol & Toxicol Unit, I-16126 Genoa, Italy
[4] Off Sci Director, Biostat Unit, Genoa, Italy
关键词
Iodinated contrast media; Computed tomography; Contrast enhancement; injection pressure; Abdominal imaging; HYPERVASCULAR HEPATOCELLULAR-CARCINOMA; HEPATIC ENHANCEMENT; INTRAVASCULAR ENHANCEMENT; IMAGE QUALITY; ANGIOGRAPHY; MDCT; DEPICTION; VISCOSITY; WEIGHT; LIVER;
D O I
10.1016/j.ejrad.2014.07.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: to compare vascular and parenchymal enhancement in abdominal computed tomography (CT) using two iodine concentrations (370 vs 300 mg I/mL) of the same contrast medium (CM) molecule (iopromide), using fixed iodine delivery rate (IDR, 1.2 g I/s) and total iodine load (630 mg I/kg). Methods: 144 patients were randomized into two groups: group A receiving iopromide 370 and group B receiving iopromide 300. Attenuation values (AV) were measured in correspondence to key anatomical structures on different phases and compared between groups with parametrical tests. Qualitative analysis was also performed. Peak injection pressure and local discomfort at the site of injection (pain and warmth) were registered. Results: mean AV of abdominal aorta in late arterial phase were 300.32 + 59.76 for group A and 298.2 +/- 59.14 for group B (p = 0.8); mean AV of portal vein in portal phase were 190.5 +/- 29.92 for group A and 192.91 +/- 24.12 for group B (p = 0.6). Mean AV of liver parenchyma in portal phase were 124.73 +/- 18.22 for group A and 125.11 +/- 15.7 for group B (p = 0.9); mean AV of liver at equilibrium were 85.11 +/- 7.75 for group A and 85.41 +/- 8.09 for group B (p = 0.8). Qualitative analysis did not show significant differences between groups (p > 0.05). Median peak injection pressure was lower in group B (93 psi, 76-172) than in group A (115 psi, 88-288, p < 0.0001), while discomfort at injection site was not significantly different (p > 0.05). Conclusions: with fixed IDR and total iodine load, comparable quantitative and qualitative enhancement can be achieved with different concentrations of the same CM. Peak injection pressure increases using CM with higher iodine concentration. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1995 / 2000
页数:6
相关论文
共 29 条
[1]   Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches [J].
Bae, Kyongtae T. .
RADIOLOGY, 2010, 256 (01) :32-61
[2]   Identification of the Iodine Concentration That Yields the Highest Intravascular Enhancement in MDCT Angiography [J].
Behrendt, Florian F. ;
Pietsch, Hubertus ;
Jost, Gregor ;
Palmowski, Moritz ;
Guenther, Rolf W. ;
Mahnken, Andreas H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (05) :1151-1156
[3]   Low-osmolar monomeric versus iso-osmolar dimeric contrast media: An intra-individual comparison in CT angiography using an animal model [J].
Behrendt, Florian F. ;
Pietsch, Hubertus ;
Jost, Gregor ;
Keil, Sebastian ;
Mottaghy, Felix M. ;
Guenther, Rolf W. ;
Mahnken, Andreas H. .
JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2011, 55 (02) :170-175
[4]   Computed Tomography Angiography The Effect of Different Chaser Flow Rates, Volumes, and Fluids on Contrast Enhancement [J].
Behrendt, Florian F. ;
Jost, Gregor ;
Pietsch, Hubertus ;
Keil, Sebastian ;
Mottaghy, Felix M. ;
Guenther, Rolf W. ;
Mahnken, Andreas H. .
INVESTIGATIVE RADIOLOGY, 2011, 46 (04) :271-276
[5]   Intra-individual comparison of different contrast media concentrations (300 mg, 370 mg and 400 mg iodine) in MDCT [J].
Behrendt, Florian F. ;
Pietsch, Hubertus ;
Jost, Gregor ;
Sieber, Martin A. ;
Keil, Sebastian ;
Plumhans, Cedric ;
Seidensticker, Peter ;
Guenther, Rolf W. ;
Mahnken, Andreas H. .
EUROPEAN RADIOLOGY, 2010, 20 (07) :1644-1650
[6]   Is Contrast Medium Osmolality a Causal Factor for Contrast-Induced Nephropathy? [J].
Bucher, AndreasM. ;
De Cecco, Carlo N. ;
Schoepf, U. Joseph ;
Meinel, Felix G. ;
Krazinski, Aleksander W. ;
Spearman, James V. ;
McQuiston, Andrew D. ;
Wang, Rui ;
Bucher, Judith ;
Vogl, Thomas J. ;
Katzberg, Richard W. .
BIOMED RESEARCH INTERNATIONAL, 2014, 2014
[7]   High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography - Iopromide 370 versus iomeprol 400 [J].
Cademartiri, F ;
de Monye, C ;
Pugliese, F ;
Mollet, NR ;
Runza, G ;
van der Lugt, A ;
Midiri, M ;
de Feyter, PJ ;
Lagalla, R ;
Krestin, GP .
INVESTIGATIVE RADIOLOGY, 2006, 41 (03) :349-353
[8]   DIAGNOSTIC POTENTIAL OF CONTRAST ENHANCEMENT PHARMACOKINETICS [J].
DEAN, PB ;
KIVISAARI, L ;
KORMANO, M .
INVESTIGATIVE RADIOLOGY, 1978, 13 (06) :533-540
[9]   Hepatic enhancement in multiphasic contrast-enhanced MDCT: Comparison of high- and low-iodine concentration contrast medium in same patients with chronic liver disease [J].
Furuta, A ;
Ito, K ;
Fujita, T ;
Koike, S ;
Shimizu, A ;
Matsunaga, N .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (01) :157-162
[10]   Impact of Iodine Delivery Rate with Varying Flow Rates on Image Quality in Dual-Energy CT of Patients with Suspected Pulmonary Embolism [J].
Hansmann, Jan ;
Fink, Christian ;
Jost, Gregor ;
Pietsch, Hubertus ;
Meyer, Mathias ;
Nance, John W., Jr. ;
Schoepf, Uwe J. ;
Attenberger, Ulrike I. ;
Schoenberg, Stefan O. ;
Henzler, Thomas .
ACADEMIC RADIOLOGY, 2013, 20 (08) :962-971