Evaluating computer-aided detection algorithms

被引:38
作者
Yoon, Hong Jun
Zheng, Bin
Sahiner, Berkman
Chakraborty, Dev P. [1 ]
机构
[1] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15261 USA
[2] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
CAD evaluation; free-response; FROC curves; lesion localization; search model; maximum likelihood; figure of merit; imaging system optimization;
D O I
10.1118/1.2736289
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Computer-aided detection (CAD) has been attracting extensive research interest during the last two decades. It is recognized that the full potential of CAD can only be realized by improving the performance and robustness of CAD algorithms and this requires good evaluation methodology that would permit CAD designers to optimize their algorithms. Free-response receiver operating characteristic (FROC) curves are widely used to assess CAD performance, however, evaluation rarely proceeds beyond determination of lesion localization fraction (sensitivity) at an arbitrarily selected value of nonlesion localizations (false marks) per image. This work describes a FROC curve fitting procedure that uses a recent model of visual search that serves as a framework for the free-response task. A maximum likelihood procedure for estimating the parameters of the model from free-response data and fitting CAD generated FROC curves was implemented. Procedures were implemented to estimate two figures of merit and associated statistics such as 95% confidence intervals and goodness of fit. One of the figures of merit does not require the arbitrary specification of an operating point at which to evaluate CAD performance. For comparison a related method termed initial detection and candidate analysis was also implemented that is applicable when all suspicious regions are reported. The two methods were tested on seven mammography CAD data sets and both yielded good to excellent fits. The search model approach has the advantage that it can potentially be applied to radiologist generated free-response data where not all suspicious regions are reported, only the ones that are deemed sufficiently suspicious to warrant clinical follow-up. This work represents the first practical application of the search model to an important evaluation problem in diagnostic radiology. Software based on this work is expected to benefit CAD developers working in diverse areas of medical imaging. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:2024 / 2038
页数:15
相关论文
共 56 条
[1]  
[Anonymous], 1999, DATA ANAL STAT COMPU
[2]  
[Anonymous], 2009, GNU SCI LIB REFERENC, Patent No. 552301619
[3]   Pulmonary nodules at chest CT: Effect of computer-aided diagnosis on radiologists' detection performance [J].
Awai, K ;
Murao, K ;
Ozawa, A ;
Komi, M ;
Hayakawa, H ;
Hori, S ;
Nishimura, Y .
RADIOLOGY, 2004, 230 (02) :347-352
[4]   Components-of-variance models and multiple-bootstrap experiments: An alternative method for random-effects, receiver operating characteristic analysis [J].
Beiden, SV ;
Wagner, RF ;
Campbell, G .
ACADEMIC RADIOLOGY, 2000, 7 (05) :341-349
[5]   A completely automated CAD system for mass detection in a large mammographic database [J].
Bellotti, R. ;
De Carlo, F. ;
Tangaro, S. ;
Gargano, G. ;
Maggipinto, G. ;
Castellano, M. ;
Massafra, R. ;
Cascio, D. ;
Fauci, F. ;
Magro, R. ;
Raso, G. ;
Lauria, A. ;
Forni, G. ;
Bagnasco, S. ;
Cerello, P. ;
Zanon, E. ;
Cheran, S. C. ;
Torres, E. Lopez ;
Bottigli, U. ;
Masala, G. L. ;
Oliva, P. ;
Retico, A. ;
Fantacci, M. E. ;
Cataldo, R. ;
De Mitri, I. ;
De Nunzio, G. .
MEDICAL PHYSICS, 2006, 33 (08) :3066-3075
[6]   Mammographic characteristics of 115 missed cancers later detected with screening mammography and the potential utility of computer-aided detection [J].
Birdwell, RL ;
Ikeda, DM ;
O'Shaughnessy, KF ;
Sickles, EA .
RADIOLOGY, 2001, 219 (01) :192-202
[7]   On the comparison of FROC curves in mammography CAD systems [J].
Bornefalk, H ;
Hermansson, AB .
MEDICAL PHYSICS, 2005, 32 (02) :412-417
[8]   Estimation and comparison of CAD system performance in clinical settings [J].
Bornefalk, H .
ACADEMIC RADIOLOGY, 2005, 12 (06) :687-694
[9]  
BRAKE GM, 1998, RADIOLOGY, V207, P465
[10]  
BUNCH PC, 1978, J APPL PHOTOGR ENG, V4, P166