Test-Retest Variability in the Characteristics of Envelope Following Responses Evoked by Speech Stimuli

被引:18
|
作者
Easwar, Vijayalakshmi [1 ,2 ,3 ]
Scollie, Susan [3 ,4 ]
Aiken, Steven [5 ]
Purcell, David [3 ,4 ]
机构
[1] Univ Wisconsin, Dept Commun Sci & Disorders, Madison, WI USA
[2] Univ Wisconsin, Waisman Ctr, Madison, WI USA
[3] Western Univ, Natl Ctr Audiol, London, ON, Canada
[4] Western Univ, Sch Commun Sci & Disorders, London, ON, Canada
[5] Dalhousie Univ, Sch Commun Sci & Disorders, Halifax, NS, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
Amplitude; Auditory steady-state response; Coefficient of variation; Detection; Fourier analyzer; Fricatives; Phase coherence; Repeatability coefficient; Vowels; FREQUENCY-FOLLOWING RESPONSE; STEADY-STATE RESPONSES; HEARING-AID GAIN; SPECTRAL DISTRIBUTION; RELIABILITY; ADULTS; COMPRESSION; POTENTIALS; BANDWIDTH; INPUT;
D O I
10.1097/AUD.0000000000000739
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives: The objective of the present study was to evaluate the between-session test-retest variability in the characteristics of envelope following responses (EFRs) evoked by modified natural speech stimuli in young normal hearing adults. Design: EFRs from 22 adults were recorded in two sessions, 1 to 12 days apart. EFRs were evoked by the token /susa integral i/ (2.05sec) presented at 65 dB SPL and recorded from the vertex referenced to the neck. The token /susa integral i/, spoken by a male with an average fundamental frequency [f(0)] of 98.53 Hz, was of interest because of its potential utility as an objective hearing aid outcome measure. Each vowel was modified to elicit two EFRs simultaneously by lowering the f(0) in the first formant while maintaining the original f(0) in the higher formants. Fricatives were amplitude-modulated at 93.02 Hz and elicited one EFR each. EFRs evoked by vowels and fricatives were estimated using Fourier analyzer and discrete Fourier transform, respectively. Detection of EFRs was determined by an F-test. Test-retest variability in EFR amplitude and phase coherence were quantified using correlation, repeated-measures analysis of variance, and the repeatability coefficient. The repeatability coefficient, computed as twice the standard deviation (SD) of test-retest differences, represents the 95% limits of test-retest variation around the mean difference. Test-retest variability of EFR amplitude and phase coherence were compared using the coefficient of variation, a normalized metric, which represents the ratio of the SD of repeat measurements to its mean. Consistency in EFR detection outcomes was assessed using the test of proportions. Results: EFR amplitude and phase coherence did not vary significantly between sessions, and were significantly correlated across repeat measurements. The repeatability coefficient for EFR amplitude ranged from 38.5 nV to 45.6 nV for all stimuli, except for /integral/ (71.6 nV). For any given stimulus, the test-retest differences in EFR amplitude of individual participants were not correlated with their test-retest differences in noise amplitude. However, across stimuli, higher repeatability coefficients of EFR amplitude tended to occur when the group mean noise amplitude and the repeatability coefficient of noise amplitude were higher. The test-retest variability of phase coherence was comparable to that of EFR amplitude in terms of the coefficient of variation, and the repeatability coefficient varied from 0.1 to 0.2, with the highest value of 0.2 for /integral/. Mismatches in EFR detection outcomes occurred in 11 of 176 measurements. For each stimulus, the tests of proportions revealed a significantly higher proportion of matched detection outcomes compared to mismatches. Conclusions: Speech-evoked EFRs demonstrated reasonable repeatability across sessions. Of the eight stimuli, the shortest stimulus /integral/ demonstrated the largest variability in EFR amplitude and phase coherence. The test-retest variability in EFR amplitude could not be explained by test-retest differences in noise amplitude for any of the stimuli. This lack of explanation argues for other sources of variability, one possibility being the modulation of cortical contributions imposed on brainstem-generated EFRs.
引用
收藏
页码:150 / 164
页数:15
相关论文
共 50 条
  • [21] Predicting Global Test-Retest Variability of Visual Fields in Glaucoma
    Choi, Eun Young
    Li, Dian
    Fan, Yuying
    Pasquale, Louis R.
    Shen, Lucy Q.
    V. Boland, Michael
    Ramulu, Pradeep
    Youse, Siamak
    De Moraes, Carlos Gustavo
    Wellik, Sarah R.
    Myers, Jonathan S.
    Bex, Peter J.
    Elze, Tobias
    Wang, Mengyu
    OPHTHALMOLOGY GLAUCOMA, 2021, 4 (04): : 390 - 399
  • [22] Vestibular Evoked Myogenic Potential (VEMP) Test-retest Reliability in Children
    Fuemmeler, Elizabeth
    Rodriguez, Amanda, I
    Thomas, Megan
    Creutz, Tom
    Fitzpatrick, Denis
    Janky, Kristen L.
    OTOLOGY & NEUROTOLOGY, 2020, 41 (08) : E1052 - E1059
  • [23] Test-retest reliability of tone-burst-evoked otoacoustic emissions
    Chan, RH
    McPherson, B
    ACTA OTO-LARYNGOLOGICA, 2000, 120 (07) : 825 - 834
  • [24] Vestibular evoked myogenic potential (VEMP) test-retest reliability in adults
    Obeidat, Faten S.
    Alghwiri, Alia A.
    Bell, Steven L.
    JOURNAL OF VESTIBULAR RESEARCH-EQUILIBRIUM & ORIENTATION, 2024, 34 (01): : 39 - 48
  • [25] Test-retest study of fMRI signal change evoked by electroacupuncture stimulation
    Kong, Jian
    Gollub, Randy L.
    Webb, J. Megan
    Kong, Jiang-Ti
    Vangel, Mark G.
    Kwong, Kenneth
    NEUROIMAGE, 2007, 34 (03) : 1171 - 1181
  • [26] Test-retest reliability of TMS motor evoked responses and silent periods during explosive voluntary isometric contractions
    Castelli, F.
    Mian, O. S.
    Bruton, A.
    Valappil, A. C.
    Tillin, N. A.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2025,
  • [27] SPEECH SAMPLE-SIZE AND TEST-RETEST STABILITY OF CONNECTED SPEECH MEASURES FOR ADULTS WITH APHASIA
    BROOKSHIRE, RH
    NICHOLAS, LE
    JOURNAL OF SPEECH AND HEARING RESEARCH, 1994, 37 (02): : 399 - 407
  • [28] Intraindividual Variability in Test-Retest Air Displacement Plethysmography Measurements of Body Density for Men and Women
    Gibson, Ann L.
    Roper, Jenevieve L.
    Mermier, Christine M.
    INTERNATIONAL JOURNAL OF SPORT NUTRITION AND EXERCISE METABOLISM, 2016, 26 (05) : 404 - 412
  • [29] Test-retest repeatability of electrically evoked isotonic power and isometric torque in the plantar flexors
    Paris, Michael T.
    Zero, Alexander M.
    Rice, Charles L.
    APPLIED PHYSIOLOGY NUTRITION AND METABOLISM, 2023, 48 (01) : 91 - 95
  • [30] Individual test-retest reliability of evoked and induced alpha activity in human EEG data
    Vazquez-Marrufo, Manuel
    Caballero-Diaz, Rocio
    Martin-Clemente, Ruben
    Galvao-Carmona, Alejandro
    Gonzalez-Rosa, Javier J.
    PLOS ONE, 2020, 15 (09):