Comparison of reversed-phase liquid chromatography-mass spectrometry with electrospray and atmospheric pressure chemical ionization for analysis of dietary tocopherols

被引:73
作者
Lanina, Svetlana A. [1 ]
Toledo, Patricia [1 ]
Sampels, Sabine [1 ]
Kamal-Eldin, Afaf [1 ]
Jastrebova, Jelena A. [1 ]
机构
[1] Swedish Univ Agr Sci, Div Food Chem, Dept Food Sci, SE-75007 Uppsala, Sweden
关键词
LC-MS; APCI; ESI; fluorinated stationary phases; tocopherols;
D O I
10.1016/j.chroma.2007.04.058
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
ESI and APCI ionization techniques in both negative and positive ion modes were evaluated for simultaneous LC-MS analysis of the four tocopherol homologues (alpha,beta,gamma and delta). The ESI and APCI ionization of tocopherols in positive ion mode was not efficient and proceeded via two competitive mechanisms, with the formation of protonated pseudo-molecular ions and molecular ions, which adversely influenced the repeatability of MS signal. Ionization in negative ion mode in both ESI and APCI was more efficient as it only produced target deprotonated pseudo-molecular ions. The APCI in negative ion mode showed larger linearity range, lower detection limits and was less sensitive to the differences in chemical structure of analytes and nature of applied solvents than negative ion ESI. Negative ion APCI was, therefore, chosen for the development of LC-MS method for simultaneous determination of the four tocopherols in foods. A baseline separation of the tocopherols was achieved on novel pentafluorophenyl silica-based column Fluophase PFP. The use of methanol-water (95:5, v/v) as a mobile phase was preferable to the use of acetonitrile-water clue to considerable gain in MS signal. The limits of quantifications were 9 ng/mL for alpha-tocopherol, 8 ng/mL for beta- and gamma- and 7.5 ng/mL for delta-tocopherol when 2 mu L was injected. This method was successfully applied to determination of tocopherols in sunflower oil and milk. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:159 / 170
页数:12
相关论文
共 51 条
[1]   Reversed-phase high-performance liquid chromatographic separations of tocopherols [J].
Abidi, SL ;
Mounts, TL .
JOURNAL OF CHROMATOGRAPHY A, 1997, 782 (01) :25-32
[2]   Normal phase high-performance liquid chromatography of tocopherols on polar phases [J].
Abidi, SL ;
Mounts, TL .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1996, 19 (04) :509-520
[3]   Chromatographic analysis of tocol-derived lipid antioxidants [J].
Abidi, SL .
JOURNAL OF CHROMATOGRAPHY A, 2000, 881 (1-2) :197-216
[4]   Analysis of vitamin E derivatives in serum using coordinated ion spray mass spectrometry [J].
Al-Talla, ZA ;
Tolley, LT .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (16) :2337-2342
[5]   Determination of vitamins A and E in infant milk formulae by high-performance liquid chromatography [J].
AlbalaHurtado, S ;
NovellaRodriguez, S ;
VecianaNogues, MT ;
MarineFont, A .
JOURNAL OF CHROMATOGRAPHY A, 1997, 778 (1-2) :243-246
[6]   Vitamin E: non-antioxidant roles [J].
Azzi, A ;
Stocker, A .
PROGRESS IN LIPID RESEARCH, 2000, 39 (03) :231-255
[7]   DETERMINATION OF TOCOPHEROLS IN VEGETABLE-OILS [J].
CARPENTER, AP .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1979, 56 (07) :668-671
[8]   Practical implications of some recent studies in electrospray ionization fundamentals [J].
Cech, NB ;
Enke, CG .
MASS SPECTROMETRY REVIEWS, 2001, 20 (06) :362-387
[9]   ANALYSIS OF PESTICIDES USING LIQUID-CHROMATOGRAPHY ATMOSPHERIC-PRESSURE CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
DOERGE, DR ;
BAJIC, S .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (11) :663-666
[10]  
Eitenmiller R.R., 1999, Vitamin E. Ch. 3 IN Vitamin Analysis for the Health and Food Sciences, P109