Determination of terbutaline enantiomers in human plasma by coupled achiral-chiral high performance liquid chromatogaphy

被引:7
|
作者
Kim, KH [1 ]
Kim, HJ
Hong, SP
Shin, SD
机构
[1] Kangweon Natl Univ, Coll Pharm, Chunchon 200701, South Korea
[2] Kyung Hee Univ, Coll Pharm, Seoul 130701, South Korea
关键词
coupled column chromatography; terbutaline; chiral separation;
D O I
10.1007/BF02976568
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Achiral-chiral column switching HPLC assay was developed to allow the separation and quantification of the enantiomers of terbutaline in human plasma by means of fluorescence detection. Plasma samples were prepared by solid-phase extraction with sep-pak silica, followed by HPLC assay. The enantiomers of terbutaline and the internal standard were separated from the biological matrix on a silica column, and the two enantiomers were resolved and quantified on a Sumichiral OA-4900 column. The two columns were connected by a switching valve equipped with silica trap column. The trap column was used to concentrate the terbutaline in the eluent from the achiral column before back flushing onto the chiral phase. For each enantiomers, the assay was linear between 2.5-125 ng/ml (r=0.9999) and detection limit was 1.0 ng/ml.
引用
收藏
页码:441 / 445
页数:5
相关论文
共 50 条
  • [21] THE MEASUREMENT OF WARFARIN ENANTIOMERS IN SERUM USING COUPLED ACHIRAL CHIRAL, HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY (HPLC)
    CHU, YQ
    WAINER, IW
    PHARMACEUTICAL RESEARCH, 1988, 5 (10) : 680 - 683
  • [22] Separation of Enantiomers of Selected Sulfur-Containing Amino Acids by Using Serially Coupled Achiral-Chiral Columns
    Deakova, Zuzana
    Durackova, Zdenka
    Armstrong, Daniel W.
    Lehotay, Jozef
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2015, 38 (07) : 789 - 794
  • [23] Stereospecific analysis of the major metabolites of ibuprofen in urine by sequential achiral-chiral high-performance liquid chromatography
    Tan, SC
    Jackson, SHD
    Swift, CG
    Hutt, AJ
    JOURNAL OF CHROMATOGRAPHY B, 1997, 701 (01): : 53 - 63
  • [24] Determination of fexofenadine enantiomers in human plasma with high-performance liquid chromatography
    Miura, Masatomo
    Uno, Tsukasa
    Tateishi, Tomonori
    Suzuki, Toshio
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (02) : 741 - 745
  • [25] DETERMINATION OF THE ENANTIOMERS OF A NEW 1,4-DIHYDROPYRIDINE CALCIUM-ANTAGONIST IN DOG PLASMA BY ACHIRAL CHIRAL COUPLED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    FUJITOMO, H
    NISHINO, I
    UENO, K
    UMEDA, T
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1993, 82 (03) : 319 - 322
  • [26] Simultaneous determination of methylphenobarbital enantiomers and phenobarbital in human plasma by on-line coupling of an achiral precolumn to a chiral liquid chromatographic column
    Ceccato, A
    Boulanger, B
    Chiap, P
    Hubert, P
    Crommen, J
    JOURNAL OF CHROMATOGRAPHY A, 1998, 819 (1-2) : 143 - 153
  • [27] Determination of rat plasma levels of sertraline enantiomers using direct injection with achiral-chiral column switching by LC-ESI/MS/MS
    Rao, R. Nageswara
    Kumar, K. Nagesh
    Shinde, Dhananjay D.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 52 (03) : 398 - 405
  • [28] DETERMINATION OF THE (+)-ENANTIOMERS AND (-)-ENANTIOMERS OF PIRPROFEN IN HUMAN-PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    SIOUFI, A
    COLUSSI, D
    MARFIL, F
    DUBOIS, JP
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 414 (01): : 131 - 137
  • [29] Achiral and chiral high-performance liquid chromatographic methods for clinafloxacin, a fluoroquinolone antibacterial, in human plasma
    Brodfuehrer, JI
    Priebe, S
    Guttendorf, R
    JOURNAL OF CHROMATOGRAPHY B, 1998, 709 (02): : 265 - 272
  • [30] DETERMINATION OF ML-1035 ENANTIOMERS IN PLASMA BY CHIRAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    MANDAGERE, AK
    OSBORNE, DR
    VAUGHN, V
    KUO, BS
    THOMPSON, TN
    CHANG, J
    BATTOR, JL
    GEARY, JI
    HWANG, KK
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1991, 9 (10-12) : 797 - 803