Group effect of Y-type perfobond rib shear connectors

被引:0
|
作者
Altanzagas, O. [1 ]
Ganzorig, E. [1 ]
Kim, S. H. [2 ]
Han, O. [2 ]
Kim, T. S. [3 ]
机构
[1] Mongolian Univ Sci & Technol, Sch Civil & Architectural Engn, Ulaanbaatar, Mongolia
[2] Yonsei Univ, Sch Civil & Environm Engn, Seoul 03722, South Korea
[3] Korea Conform Labs, Consumer Prod Business Div, Seoul 08503, South Korea
关键词
Y-type perfobond rib shear connector; push-out test; group shear connector; rib arrangement and spacmg; RESISTANCE;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Many shear connectors may need to be arranged together in group to achieve the required shear strength in the design stage of the composite connection. In most practical situations the space to install the shear connectors may be limited. The shear strength of the individual Y-type perfobond rib shear connector may not be obtained if the Y-type perfobond rib shear connector layers are placed too much close to other adjacent layers. It has been investigated in the previous study that the total shear resistance of the flat-type perfobond rib shear connector group may either increase or decrease depending on the spacing between the adjacent layers. This study is designed to verify the effect of the spacing between the adjacent layers of Y-type perfobond rib shear connectors and propose the proper design rule to estimate the shear strength in the multi-layer shear connectors. The double layer specimens with various spacings have been push tested. The minimum adjacent spacing for the specimens has been selected considering the limited distance due to the inclined Y-ribs to each other. The Y-ribs in the standard Y-type perfobond rib shear connector are inclined with 30-degree, and may bother the Y-ribs from the adjacent shear connector. Two different spacings of 120 mm and 300 mm are selected as the minimum and maximum distances. The maximum 300 mm spacing is selected considering the height of the shear connector. The parametric study for the spacings between 120 and 300 mm have been performed using the numerical FEM models. The numerical FEM model has been verified and improved based on the experimental test results. The effect of transverse rebar diameters is also examined. The shear resistance formula is proposed for the double layer shear connectors.
引用
收藏
页码:401 / 407
页数:7
相关论文
共 50 条
  • [1] Effect of rebar strength in Y-type perfobond rib shear connectors
    Kim, S. H.
    Han, O.
    Kim, K. S.
    Kim, S. J.
    Shin, J. Y.
    MAINTENANCE, SAFETY, RISK, MANAGEMENT AND LIFE-CYCLE PERFORMANCE OF BRIDGES, 2018, : 381 - 385
  • [2] Energy dissipating characteristics of Y-type perfobond rib shear connectors
    Kim, S. H.
    Kim, K. S.
    Han, O.
    Choi, J. G.
    MAINTENANCE, SAFETY, RISK, MANAGEMENT AND LIFE-CYCLE PERFORMANCE OF BRIDGES, 2018, : 386 - 389
  • [3] Generalized formulation for shear resistance on Y-type perfobond rib shear connectors
    Kim, Sang-Hyo
    Park, Sejun
    Kim, Kun-Soo
    Jung, Chi-Young
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 128 : 245 - 260
  • [4] Behavior of composite girder with Y-type perfobond rib shear connectors
    Kim, Sang-Hyo
    Choi, Jaegu
    Park, Se-Jun
    Ahn, Jin-Hee
    Jung, Chi-Young
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 103 : 275 - 289
  • [5] Y-type perfobond rib shear connectors subjected to fatigue loading on highway bridges
    Kim, Sang-Hyo
    Kim, Kun-Soo
    Park, Sejun
    Aim, Jin-Hee
    Lee, Min-Kyu
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 122 : 445 - 454
  • [6] Experimental behavior of double-row Y-type perfobond rib shear connectors
    Kim, Sang-Hyo
    Han, Oneil
    Kim, Kun-Soo
    Park, Jun-Seung
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 150 : 221 - 229
  • [7] Comparison of hysteretic performance of stubby Y-type perfobond rib and stud shear connectors
    Kim, Sang-Hyo
    Kim, Kun-Soo
    Park, Sejun
    Jung, Chi -Young
    Choi, Jae-Gu
    ENGINEERING STRUCTURES, 2017, 147 : 114 - 124
  • [8] Analysis of the Shear Behavior of Stubby Y-Type Perfobond Rib Shear Connectors for a Composite Frame Structure
    Kim, Sang-Hyo
    Kim, Kun-Soo
    Lee, Do-Hoon
    Park, Jun-Seung
    Han, Oneil
    MATERIALS, 2017, 10 (11):
  • [9] Numerical simulation of Y-type perfobond rib shear connectors using finite element analysis
    Kim, Kun-Soo
    Han, Oneil
    Gombosuren, Munkhtulga
    Kim, Sang-Hyo
    STEEL AND COMPOSITE STRUCTURES, 2019, 31 (01): : 53 - 67
  • [10] Hysteretic performance of stubby Y-type perfobond rib shear connectors depending on transverse rebar
    Kim, Kun-Soo
    Han, Oneil
    Choi, Jonghee
    Kim, Sang-Hyo
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 200 : 64 - 79