Comparison of Iohexol-380 and Iohexol-350 for Coronary CT Angiography: A Multicenter, Randomized, Double-Blind Phase 3 Trial

被引:5
作者
Park, Eun-Ah [1 ]
Lee, Whal [1 ]
Kang, Doo Kyoung [2 ]
Kim, Sung Jin [3 ]
Kim, Young-Ju [4 ]
Kim, Yookyung [5 ]
Sung, Yon Mi [6 ]
Song, Soon-Young [7 ]
Oh, Yu-Whan [8 ]
Yong, Hwan Seok [9 ]
Lee, Heon [10 ]
Jeon, Eui-Yong [11 ]
Jin, Gong-Yong [12 ,13 ]
Choi, Byoung Wook [14 ]
Choi, Sang-Il [15 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, 101 Daehak Ro, Seoul 03080, South Korea
[2] Ajou Univ, Sch Med, Dept Radiol, Suwon 16499, South Korea
[3] Chungbuk Natl Univ Hosp, Dept Radiol, Cheongju 28644, South Korea
[4] Yonsei Univ, Wonju Severance Christian Hosp, Wonju Coll Med, Dept Radiol, Wonju 26426, South Korea
[5] Ewha Womans Univ, Mokdong Hosp, Dept Radiol, Seoul 07985, South Korea
[6] Gachon Univ, Gil Med Ctr, Dept Radiol, Inchon 21565, South Korea
[7] Hanyang Univ, Seoul Hosp, Dept Radiol, Seoul 04763, South Korea
[8] Korea Univ, Anam Hosp, Dept Radiol, Seoul 02841, South Korea
[9] Korea Univ, Guro Hosp, Dept Radiol, Seoul 08308, South Korea
[10] Soonchunhyang Univ, Bucheon Hosp, Dept Radiol, Bucheon 14584, South Korea
[11] Hallym Univ, Sacred Heart Hosp, Dept Radiol, Anyang 14068, South Korea
[12] Chonbuk Natl Univ Med Sch & Hosp, Res Inst Clin Med, Inst Med Sci, Dept Radiol, Jeonju 54907, South Korea
[13] Biomed Res Inst, Jeonju 54907, South Korea
[14] Yonsei Univ Hlth Syst, Severance Hosp, Dept Radiol, Seoul 03722, South Korea
[15] Seoul Natl Univ, Bundang Hosp, Dept Radiol, Songnam 13620, South Korea
关键词
Coronary arteries; Contrast media; Contrast materials; Drug safety; Image quality enhancement; CONCENTRATION CONTRAST-MEDIA; COMPUTED-TOMOGRAPHY; IODINE-CONCENTRATION; IMAGE QUALITY; IOMEPROL; 400; CARDIAC CT; ENHANCEMENT; PRINCIPLES; ATTENUATION; RATIONALE;
D O I
10.3348/kjr.2016.17.3.330
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: This multi-center, randomized, double-blind, phase 3 trial was conducted to compare the safety and efficacy of contrast agents iohexol-380 and iohexol-350 for coronary CT angiography in healthy subjects. Materials and Methods: Volunteers were randomized to receive 420 mgI/kg of either iohexol-350 or iohexol-380 using a flow rate of 4 mL/sec. All adverse events were recorded. Two blinded readers independently reviewed the CT images and conflicting results were resolved by a third reader. Luminal attenuations (ascending aorta, Left main coronary artery, and Left ventricle) in Hounsfield units (HUs) and image quality on a 4-point scale were calculated. Results: A total of 225 subjects were given contrast media (115 with iohexol-380 and 110 with iohexoL-350). There was no difference in number of adverse drug reactions between groups: 75 events in 56 (48.7%) of 115 subjects in the iohexol-380 group vs. 74 events in 51 (46.4%) of 110 subjects in the iohexol-350 group (p = 0.690). No severe adverse drug reactions were recorded. Neither group showed an increase in serum creatinine. Significant differences in mean density between the groups was found in the ascending aorta: 375.8 71.4 HU with iohexol-380 vs. 356.3 61.5 HU with iohexoL-350 (p = 0.030). No significant differences in image quality scores between both groups were observed for all three anatomic evaluations (all, p > 0.05). Conclusion: Iohexol-380 provides improved enhancement of the ascending aorta and similar attenuation of the coronary arteries without any increase in adverse drug reactions, as compared with iohexol-350 using an identical amount of total iodine.
引用
收藏
页码:330 / 338
页数:9
相关论文
共 20 条
  • [1] Scan and contrast administration principles of MDCT
    Bae, KT
    Heiken, JP
    [J]. EUROPEAN RADIOLOGY, 2005, 15 : E46 - E59
  • [2] Peak contrast enhancement in CT and MR angiography: When does it occur and why? Pharmacokinetic study in a porcine model
    Bae, KT
    [J]. RADIOLOGY, 2003, 227 (03) : 809 - 816
  • [3] Optimal contrast application for cardiac 4-detector-row computed tomography
    Becker, CR
    Hong, C
    Knez, A
    Leber, A
    Bruening, R
    Schoepf, UJ
    Reiser, MF
    [J]. INVESTIGATIVE RADIOLOGY, 2003, 38 (11) : 690 - 694
  • [4] Intra-individual comparison of different contrast media concentrations (300 mg, 370 mg and 400 mg iodine) in MDCT
    Behrendt, Florian F.
    Pietsch, Hubertus
    Jost, Gregor
    Sieber, Martin A.
    Keil, Sebastian
    Plumhans, Cedric
    Seidensticker, Peter
    Guenther, Rolf W.
    Mahnken, Andreas H.
    [J]. EUROPEAN RADIOLOGY, 2010, 20 (07) : 1644 - 1650
  • [5] Use of high concentration contrast media (HCCM): principles and rationale - body CT
    Brink, JA
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2003, 45 : S53 - S58
  • [6] Parameters affecting bolus geometry in CTA: A review
    Cademartiri, F
    van der Lugt, A
    Luccichenti, G
    Pavone, P
    Krestin, GP
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (04) : 598 - 607
  • [7] Intravenous contrast material administration at helical 16-detector row CT coronary angiography: Effect of iodine concentration on vascular attenuation
    Cademartiri, F
    Mollet, NR
    van der Lugt, A
    McFadden, EP
    Stijnen, T
    de Feyter, PJ
    Krestin, GP
    [J]. RADIOLOGY, 2005, 236 (02) : 661 - 665
  • [8] High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography - Iopromide 370 versus iomeprol 400
    Cademartiri, F
    de Monye, C
    Pugliese, F
    Mollet, NR
    Runza, G
    van der Lugt, A
    Midiri, M
    de Feyter, PJ
    Lagalla, R
    Krestin, GP
    [J]. INVESTIGATIVE RADIOLOGY, 2006, 41 (03) : 349 - 353
  • [9] Cademartiri Filippo, 2006, AJR Am J Roentgenol, V187, pW430, DOI 10.2214/AJR.05.1406
  • [10] 80-kV Pulmonary CT Angiography With 40 mL of Iodinated Contrast Material in Lean Patients: Comparison of Vascular Enhancement With Iodixanol (320 mg I/mL) and Iomeprol (400 mg I/mL)
    Faggioni, Lorenzo
    Neri, Emanuele
    Sbragia, Paola
    Pascale, Rachele
    D'Errico, Luigia
    Caramella, Davide
    Bartolozzi, Carlo
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (06) : 1220 - 1225