Use of resonance frequency analysis to evaluate the effects of surface properties on the stability of different implants

被引:12
作者
Gursoytrak, Burcu [1 ]
Ataoglu, Hanife [2 ]
机构
[1] Adnan Menderes Univ, Fac Dent, Dept Oral & Maxillofacial Surg, Aydin, Turkey
[2] Medipol Univ, Fac Dent, Dept Oral & Maxillofacial Surg, Istanbul, Turkey
关键词
alkali-modified surfaced implants; dental implant surface; implant stability; resonance frequency analysis; RETAINED MANDIBULAR OVERDENTURES; TITANIUM IMPLANTS; IN-VIVO; BONE; PLASMA;
D O I
10.1111/clr.13560
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives We performed a randomized clinical study evaluating the stability of implants with different surfaces (alkali-modified or sandblasted) via resonance frequency analysis (RFA). Materials and Methods Fourteen patients who were bilaterally edentulous in terms of their mandibular molars were enrolled. Implants with alkali-modified (bioactive) and sandblasted surfaces were randomly placed in either hemi-arch; the 50 implants used were identical in terms of diameter and length. RFA was used to measure the implant stability quotient (ISQ) immediately after placement (to assess primary stability) and 2, 6, and 12 weeks later. Results The average RFA value for alkali-modified implants was significantly higher than that for sandblasted implants immediately after implantation, but the ISQs fell rapidly and were similar in the two groups at 2 and 6 weeks (p > .05); ISQ values were the same in the two groups at 3 months (p > .05). Conclusions Implants with alkali-modified surfaces were more stable than implants with sandblasted surfaces at all times after placement. The ISQs of bioactive implants exhibiting high-level primary stability fell to greater extents than did those of implants with sandblasted surfaces at 2 and 6 weeks postoperatively; both types of implant yielded similar clinical results at 12 weeks postoperatively.
引用
收藏
页码:239 / 245
页数:7
相关论文
共 48 条
  • [1] Impact of Bone Quality and Implant Type on the Primary Stability: An Experimental Study Using Bovine Bone
    Anil, Sukumaran
    Aldosari, Abdullah Alfarraj
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (02) : 144 - 148
  • [2] Balshi T J, 1997, Implant Dent, V6, P83, DOI 10.1097/00008505-199700620-00002
  • [3] Barewal RM, 2003, INT J ORAL MAX IMPL, V18, P641
  • [4] Implant stability measurement of delayed and immediately loaded implants during healing. A clinical resonance-frequency analysis study with sandblasted-and-etched ITI implants
    Bischof, M
    Nedir, R
    Szmukler-Moncler, S
    Bernard, JP
    Samson, J
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (05) : 529 - 539
  • [5] Highly Bioactive 8 nm Hydrothermal TiO2 Nanotubes Elicit Enhanced Bone Cell Response
    Brammer, Karla S.
    Kim, Hyunsu
    Noh, Kunbae
    Loya, Mariana
    Frandsen, Christine J.
    Chen, Li-han
    Connelly, Laura S.
    Jin, Sungho
    [J]. ADVANCED ENGINEERING MATERIALS, 2011, 13 (03) : B88 - B94
  • [6] Branemark PI., 1985, TISSUE INTEGRATED PR, P11
  • [7] EFFECT OF MOVEMENT ON BONDING OF POROUS METAL TO BONE
    CAMERON, HU
    PILLIAR, RM
    MACNAB, I
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1973, 7 (04): : 301 - 311
  • [8] Cochran D. L., 2000, BONE ENG, P391
  • [9] Davies JE, 1998, INT J PROSTHODONT, V11, P391
  • [10] Degidi M., 2004, J ORAL IMPLANTOL, V5, P289