High-Resolution Peripheral Quantitative Computed Tomography Can Assess Microstructural and Mechanical Properties of Human Distal Tibial Bone

被引:185
|
作者
Liu, X. Sherry [1 ]
Zhang, X. Henry [1 ]
Sekhon, Kiranjit K. [1 ]
Adams, Mark F. [2 ]
McMahon, Donald J. [3 ]
Bilezikian, John P. [3 ]
Shane, Elizabeth [3 ]
Guo, X. Edward [1 ]
机构
[1] Columbia Univ, Dept Biomed Engn, Bone Bioengn Lab, New York, NY 10027 USA
[2] Columbia Univ, Dept Appl Phys & Appl Math, New York, NY 10027 USA
[3] Columbia Univ, Div Endocrinol, Dept Med, New York, NY 10027 USA
基金
美国国家卫生研究院;
关键词
BONE MICROSTRUCTURE; BONE STIFFNESS; FINITE ELEMENT MODEL; HIGH-RESOLUTION PERIPHERAL QUANTITATIVE COMPUTED TOMOGRAPHY; MICRO-COMPUTED TOMOGRAPHY; TRABECULAR BONE; ELASTIC PROPERTIES; APPARENT MODULUS; CANCELLOUS BONE; VIVO; RADIUS; FRACTURE; QUANTIFICATION; ARCHITECTURE; THICKNESS;
D O I
10.1359/jbmr.090822
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
High-resolution peripheral quantitative computed tomography (HR-pQCT) is a newly developed in vivo clinical imaging modality It can assess the 3D microstructure of cortical and trabecular bone at the distal radius and tibia and is suitable as an input for microstructural finite element (mu FE) analysis to evaluate bone's mechanical competence In order for microstructural and image-based mu FE analyses to become standard clinical tools, validation with a current gold standard, namely, high-resolution micro-computed tomography (mu CT), is required Microstructural measurements of 19 human cadaveric distal tibiae were performed for the registered HR-pQCT and mu CT images, respectively. Next, whole bone stiffness, trabecular bone stiffness, and elastic moduli of cubic subvolumes of trabecular bone in both HR-pQCT and mu CT images were determined by mu FE analysis The standard HR-pQCT patient protocol measurements, derived bone volume fraction (BV/TVd), trabecular number (Tb N+), trabecular thickness (Tb Th), trabecular spacing (Tb.Sp), and cortical thickness (Ct Th), as well as the voxel-based direct measurements, BV/TV, Tb N+, Tb Th+, Tb Sp(+), Ct Th, bone surface-to-volume ratio (BS/BV), structure model index (SMI), and connectivity density (Conn.D), correlated well with their respective gold standards, and both contributed to mu FE-predicted mechanical properties in either single or multiple linear regressions The mechanical measurements, although overestimated by HR-pQCT, correlated highly with their gold standards Moreover, elastic moduli of cubic subvolumes of trabecular bone predicted whole bone or trabecular bone stiffness in distal tibia We conclude that microstructural measurements and mechanical parameters of distal tibia can be efficiently derived from HR-pQCT images and provide additional information regarding bone fragility (C) 2010 American Society for Bone and Mineral Research.
引用
收藏
页码:746 / 756
页数:11
相关论文
共 50 条
  • [1] Accuracy of High-Resolution In Vivo Micro Magnetic Resonance Imaging for Measurements of Microstructural and Mechanical Properties of Human Distal Tibial Bone
    Liu, X. Sherry
    Zhang, X. Henry
    Rajapakse, Chamith S.
    Wald, Michael J.
    Magland, Jeremy
    Sekhon, Kiranjit K.
    Adam, Mark F.
    Sajda, Paul
    Wehrli, Felix W.
    Guo, X. Edward
    JOURNAL OF BONE AND MINERAL RESEARCH, 2010, 25 (09) : 2039 - 2050
  • [2] High resolution peripheral quantitative computed tomography for the assessment of morphological and mechanical bone parameters
    Fuller, Henrique
    Fuller, Ricardo
    Pereira, Rosa Maria R.
    REVISTA BRASILEIRA DE REUMATOLOGIA, 2015, 55 (04) : 352 - 362
  • [3] High-resolution peripheral quantitative computed tomography (HR-VICT) can assess microstructural and biomechanical properties of both human distal radius and tibia: Ex vivo computational and experimental validations
    Zhou, Bin
    Wang, Ji
    Yu, Y. Eric
    Zhang, Zhendong
    Nawathe, Shashank
    Nishiyama, Kyle K.
    Rosete, Fernando Rey
    Keaveny, Tony M.
    Shane, Elizabeth
    Guo, X. Edward
    BONE, 2016, 86 : 58 - 67
  • [4] Automated simulation of areal bone mineral density assessment in the distal radius from high-resolution peripheral quantitative computed tomography
    Burghardt, A. J.
    Kazakia, G. J.
    Link, T. M.
    Majumdar, S.
    OSTEOPOROSIS INTERNATIONAL, 2009, 20 (12) : 2017 - 2024
  • [5] Bone strength at the distal radius can be estimated from high-resolution peripheral quantitative computed tomography and the finite element method
    MacNeil, Joshua A.
    Boyd, Steven K.
    BONE, 2008, 42 (06) : 1203 - 1213
  • [6] Accuracy of high-resolution peripheral quantitative computed tomography for measurement of bone quality
    MacNeil, Joshua A.
    Boyd, Steven K.
    MEDICAL ENGINEERING & PHYSICS, 2007, 29 (10) : 1096 - 1105
  • [7] Accuracy of volumetric bone mineral density measurement in high-resolution peripheral quantitative computed tomography
    Sekhon, Kiranjit
    Kazakia, Galateia J.
    Burghardt, Andrew J.
    Hermannsson, Bryan
    Majumdar, Sharmila
    BONE, 2009, 45 (03) : 473 - 479
  • [8] Human Bone Loss Assessed by High-Resolution Peripheral Quantitative Computed Tomography and Ultrasonic Transmission Techniques
    Bi, Dongsheng
    Liu, Chengcheng
    Dai, Zhongquan
    Li, Zhili
    Li, Ying
    Li, Boyi
    Li, Dan
    Wang, Linjie
    Qu, Lina
    Li, Yinghui
    Ta, Dean
    MICROGRAVITY SCIENCE AND TECHNOLOGY, 2023, 35 (02)
  • [9] High-resolution peripheral quantitative computed tomography in children with osteogenesis imperfecta
    Fennimore, David J.
    Digby, Maria
    Paggiosi, Margaret
    Arundel, Paul
    Bishop, Nick J.
    Dimitri, Paul
    Offiah, Amaka C.
    PEDIATRIC RADIOLOGY, 2020, 50 (12) : 1781 - 1787
  • [10] Improved reproducibility of high-resolution peripheral quantitative computed tomography for measurement of bone quality
    MacNeil, Joshua A.
    Boyd, Steven K.
    MEDICAL ENGINEERING & PHYSICS, 2008, 30 (06) : 792 - 799