Influence of fibre orientation on the tensile performance of sandwich composites in fire

被引:21
作者
Anjang, A. [1 ,2 ]
Mouritz, A. P. [1 ]
Feih, S. [1 ,3 ]
机构
[1] RMIT Univ, Sch Engn, Sir Lawrence Wackett Aerosp Res Ctr, Melbourne, Vic 3001, Australia
[2] Univ Sains Malaysia, Sch Aerosp Engn, Nibong Tebal 14300, Malaysia
[3] Singapore Inst Mfg Technol SIMTech, Joining Technol Grp, 2 Fusionopolis Way, Singapore 138634, Singapore
关键词
Sandwich structures; Glass fibres; High temperature properties; Analytical modelling; FRP COMPOSITES; STRUCTURAL RESISTANCE; COMPRESSION; FAILURE; STRENGTH; MODEL; BEHAVIOR; DEGRADATION; PANELS; LOAD;
D O I
10.1016/j.compositesa.2017.05.028
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The effect of fibre orientation on the tensile load-bearing performance of sandwich composite materials in fire is investigated experimentally and analytically. The orientation of the glass fibres in the laminate skins was set at 0 (perfectly aligned in the load direction), or offset at angles of 9, 15, 30 or 45. The influence of fibre orientation on the time-to-failure and failure mechanism during fire exposure is investigated. Experimental testing reveals that the structural performance of the sandwich composite deteriorates rapidly with increasing fibre offset angle due to glass transition softening of the polymer matrix becoming more dominant, and the fibre properties being less important as the laminate skins thermally soften and decompose. A thermal-mechanical model is presented to analyse the deterioration to the tension load-bearing performance with increasing fibre offset angle, and the analysis reveals that even small fibre offset angles have a substantial adverse impact on the fire performance of sandwich composites. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:342 / 351
页数:10
相关论文
共 40 条
[1]   Deterioration of the fire structural resistance of sandwich composite under tension due to water absorption [J].
Anjang, A. ;
Chevali, V. S. ;
Feih, S. ;
Mouritz, A. P. .
COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2016, 87 :263-270
[2]   Tension modelling and testing of sandwich composites in fire [J].
Anjang, A. ;
Chevali, V. S. ;
Kandare, E. ;
Mouritz, A. P. ;
Feih, S. .
COMPOSITE STRUCTURES, 2014, 113 :437-445
[3]   Structural response of FRP composites during fire [J].
Asaro, Robert J. ;
Lattimer, Brian ;
Ramroth, William .
COMPOSITE STRUCTURES, 2009, 87 (04) :382-393
[4]   Composite life under sustained compression and one sided simulated fire exposure: Characterization and prediction [J].
Bausano, John V. ;
Lesko, John J. ;
Case, Scott W. .
COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2006, 37 (07) :1092-1100
[5]   Compressive softening and failure of basalt fibre composites in fire: Modelling and experimentation [J].
Bhat, T. ;
Kandare, E. ;
Gibson, A. G. ;
Di Modica, P. ;
Mouritz, A. P. .
COMPOSITE STRUCTURES, 2017, 165 :15-24
[6]   Fire structural resistance of basalt fibre composite [J].
Bhat, T. ;
Chevali, V. ;
Liu, X. ;
Feih, S. ;
Mouritz, A. P. .
COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2015, 71 :107-115
[7]   Compression creep rupture behavior of a glass/vinyl ester composite subject to isothermal and one-sided heat flux conditions [J].
Boyd, Steven E. ;
Case, Scott W. ;
Lesko, John J. .
COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2007, 38 (06) :1462-1472
[8]   Compression Failure of Carbon Fiber-Epoxy Laminates in Fire [J].
Burns, L. A. ;
Feih, S. ;
Mouritz, A. P. .
JOURNAL OF AIRCRAFT, 2010, 47 (02) :528-533
[9]   A review of the fire behaviour of pultruded GFRP structural profiles for civil engineering applications [J].
Correia, Joao R. ;
Bai, Yu ;
Keller, Thomas .
COMPOSITE STRUCTURES, 2015, 127 :267-287
[10]  
Dimitrienko Y.I., 1999, Thermomechanics of composites under high temperatures