Effect of tilt angle and connection mode of PVT modules on the energy efficiency of a hot water system for high-rise residential buildings

被引:37
作者
Sun, L. L. [1 ]
Li, M. [2 ]
Yuan, Y. P. [1 ]
Cao, X. L. [1 ]
Lei, B. [1 ]
Yu, N. Y. [1 ]
机构
[1] Southwest Jiaotong Univ, Sch Mech Engn, Chengdu, Sichuan, Peoples R China
[2] Cent S Univ, Sch Energy Sci & Engn, Changsha, Hunan, Peoples R China
关键词
Photovoltaic thermal module; Natural circulation; Connection mode; Tilt angle; THERMAL SOLAR-COLLECTOR; HEATING-SYSTEM; PERFORMANCE;
D O I
10.1016/j.renene.2016.02.075
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The tilt angle and connection mode of PVT modules are critical factors influencing the energy efficiency of PVT systems. To evaluate their effect, we built a PVT hot water system which is naturally driven by gravity and the PVT modules are installed on vertical facades of high-rise residential buildings. We develop a dynamic model for the simulation of the PVT hot water system. The simulation results are in good agreement with indoor experimental data. Compared with parallel connection, electric power for series connection decreases by 2.0%, thermal energy increases by 11.4% and total energy increases by 5.4%. The connection mode has more obvious influences on thermal energy than electrical power. Considering only total energy, PVT modules with a tilt angle of 20 degrees can produce maximum energy benefits. However, the projection lengths of PVT modules should also be considered when selecting the optimum tilt angle. The optimum tilt angle is chosen as 40 degrees when both total energy and projection length are considered. These findings are good references for the installation of PVT modules on vertical facades of high-rise residential buildings. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:291 / 301
页数:11
相关论文
共 28 条
[1]  
[Anonymous], 2004, PHOTOVOLTAIC ARRAY P, DOI DOI 10.2172/919131
[2]  
[Anonymous], 1995, GUID EXPR UNC MEAS
[3]   Photovoltaic cogeneration in the built environment [J].
Bazilian, MD ;
Leenders, F ;
Van der Ree, BGC ;
Prasad, D .
SOLAR ENERGY, 2001, 71 (01) :57-69
[4]  
Buker M. S., 2014, ENERGY BUILD, V76, P64
[5]   An experimental study of facade-integrated photovoltaic/water-heating system [J].
Chow, T. T. ;
He, W. ;
Ji, J. .
APPLIED THERMAL ENGINEERING, 2007, 27 (01) :37-45
[6]   A review on photovoltaic/thermal hybrid solar technology [J].
Chow, T. T. .
APPLIED ENERGY, 2010, 87 (02) :365-379
[7]   Annual performance of building-integrated photovoltaic/water-heating system for warm climate application [J].
Chow, T. T. ;
Chan, A. L. S. ;
Fong, K. F. ;
Lin, Z. ;
He, W. ;
Ji, I. .
APPLIED ENERGY, 2009, 86 (05) :689-696
[8]   Experimental and numerical investigation on thermal and electrical performance of a building integrated photovoltaic-thermal collector system [J].
Corbin, Charles D. ;
Zhai, Zhiqiang John .
ENERGY AND BUILDINGS, 2010, 42 (01) :76-82
[9]   Hybrid photovoltaic/thermal (PV/T) solar systems simulation with Simulink/Matlab [J].
da Silva, R. M. ;
Fernandes, J. L. M. .
SOLAR ENERGY, 2010, 84 (12) :1985-1996
[10]  
Duffle JA., 2006, Solar engineering of thermal processes, V3rd