Noninvasive Assessment of Cardiac Output in Advanced Heart Failure and Heart Transplant Candidates Using the Bioreactance Method

被引:2
作者
Pandhita, Bashar A. W. [1 ,2 ,3 ,4 ]
Okwose, Nduka C. [1 ,2 ,3 ,4 ]
Koshy, Aaron [1 ,2 ,3 ,4 ]
Fernandez, Oscar G. [1 ,2 ,3 ,4 ]
Cruz, Noelia B. [1 ,2 ,3 ,4 ]
Eggett, Christopher [1 ,2 ,3 ,4 ]
Velicki, Lazar [5 ,6 ]
Popovic, Dejana [7 ]
MacGowan, Guy A. [1 ,2 ,3 ,4 ]
Jakovljevic, Djordje G. [1 ,2 ,3 ,4 ]
机构
[1] Newcastle Univ, Fac Med Sci, Cardiovasc Res Inst, Newcastle Upon Tyne, Tyne & Wear, England
[2] Newcastle Univ, Fac Med Sci, Clin & Translat Res Inst, Newcastle Upon Tyne, Tyne & Wear, England
[3] Newcastle Univ, Fac Med Sci, Biosci Res Inst, Newcastle Upon Tyne, Tyne & Wear, England
[4] Newcastle Tyne Hosp NHS Fdn Trust, Newcastle Upon Tyne, Tyne & Wear, England
[5] Univ Novi Sad, Fac Med, Novi Sad, Serbia
[6] Inst Cardiovasc Dis Vojvodina, Dept Cardiovasc Surg, Novi Sad, Serbia
[7] Univ Belgrade, Univ Clin Ctr Serbia, Div Cardiol, Fac Pharm, Belgrade, Serbia
关键词
bioreactance; cardiac monitoring; cardiac output; heart failure; thermodilution; POWER OUTPUT; EXERCISE; MONITORS; COMPLICATIONS; METAANALYSIS; ABILITY;
D O I
10.1053/j.jvca.2020.09.109
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objectives: The aim of the present study was to assess the validity and trending ability of the bioreactance method in estimating cardiac output at rest and in response to stress in advanced heart failure patients and heart transplant candidates. Design: This was a prospective single-center study. Setting: This study was conducted at the heart transplant center at the Freeman Hospital, Newcastle upon Tyne, UK. Participants: Eighteen patients with advanced chronic heart failure due to reduced left ventricular ejection fraction (19 +/- 7%), and peak oxygen consumption 12.3 +/- 3.9 mL/kg/min. Interventions: Participants underwent right heart catheterization using the Swan-Ganz catheter. Measurements and Main Results: Cardiac output was measured simultaneously using thermodilution and bioreactance at rest and during active straight leg raise test to volitional exertion. There was no significant difference in cardiac index values obtained by the thermodilution and bioreactance methods (2.26 +/- 0.59 v 2.38 +/- 0.50 L/min, p > 0.05) at rest and peak straight leg raise test (2.92 +/- 0.77 v 3.01 +/- 0.66 L/min, p > 0.05). In response to active leg raise test, thermodilution cardiac output increased by 22% and bioreactance by 21%. There was also a strong relationship between cardiac outputs from both methods at rest (r = 0.88, p < 0.01) and peak straight leg raise test (r = 0.92, p < 0.01). Cartesian plot analysis showed good trending ability of bioreactance compared with thermodilution (concordance rate = 93%) Conclusions: 'Cardiac output measured by the bioreactance method is comparable to that from the thermodilution method. Bioreactance method may be used in clinical practice to assess hemodynamics and improve management of advanced heart failure patients undergoing heart transplant assessment. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:1776 / 1781
页数:6
相关论文
共 32 条
  • [1] Noninvasive measurement of cardiac output during exercise by inert gas rebreathing technique: A new tool for heart failure evaluation
    Agostoni, P
    Cattadori, G
    Apostolo, A
    Contini, M
    Palermo, P
    Marenzi, G
    Wasserman, K
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (09) : 1779 - 1781
  • [2] Effect of the degree of tricuspid regurgitation on cardiac output measurements by thermodilution
    Balik, M
    Pachl, J
    Hendl, J
    [J]. INTENSIVE CARE MEDICINE, 2002, 28 (08) : 1117 - 1121
  • [3] A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    Critchley, LAH
    Critchley, JAJH
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) : 85 - 91
  • [4] Assessment of Trending Ability of Cardiac Output Monitors by Polar Plot Methodology
    Critchley, Lester A.
    Yang, Xiao X.
    Lee, Anna
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2011, 25 (03) : 536 - 546
  • [5] A Critical Review of the Ability of Continuous Cardiac Output Monitors to Measure Trends in Cardiac Output
    Critchley, Lester A.
    Lee, Anna
    Ho, Anthony M. -H.
    [J]. ANESTHESIA AND ANALGESIA, 2010, 111 (05) : 1180 - 1192
  • [6] Application of bioreactance for cardiac output assessment during exercise in healthy individuals
    Elliott, Adrian
    Hull, James H.
    Nunan, David
    Jakovljevic, Djordje G.
    Brodie, David
    Ansley, Lesley
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2010, 109 (05) : 945 - 951
  • [7] Cardiac output measurements using the bioreactance technique in critically ill patients
    Fagnoul, David
    Vincent, Jean-Louis
    De Backer, Daniel
    [J]. CRITICAL CARE, 2012, 16 (06):
  • [8] Minimally Invasive Cardiac Output Monitoring in the Perioperative Setting
    Funk, Duane J.
    Moretti, Eugene W.
    Gan, Tong J.
    [J]. ANESTHESIA AND ANALGESIA, 2009, 108 (03) : 887 - 897
  • [9] Flow dependency of error in thermodilution measurement of cardiac output during acute tricuspid regurgitation
    Heerdt, PM
    Blessios, GA
    Beach, ML
    Hogue, CW
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2001, 15 (02) : 183 - 187
  • [10] Complications of right heart catheterization procedures in patients with pulmonary hypertension in experienced centers
    Hoeper, Marius M.
    Lee, Stephen H.
    Voswinckel, Robert
    Palazzini, Massimillano
    Jais, Xavier
    Marinelli, Alessandro
    Barst, Robyn J.
    Ghofrani, Hossein A.
    Jing, Zhi-Cheng
    Opitz, Christian
    Seyfarth, Hans-Juergen
    Halank, Michael
    McLaughlin, Vallerie
    Oudiz, Ronald J.
    Ewert, Ralf
    Wilkens, Heinrike
    Kluge, Stefan
    Bremer, Hinrich-Cordt
    Baroke, Eva
    Rubin, Lewis J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (12) : 2546 - 2552