Dynamic response of dry cask storage systems for spent nuclear fuel to near field blast loading

被引:2
作者
Hanifehzadeh, Mohammad [1 ]
Gencturk, Bora [2 ]
机构
[1] Univ Southern Calif, Dept Civil & Environm Engn, Los Angeles, CA 90089 USA
[2] Univ Southern Calif, Sonny Astani Dept Civil & Environm Engn, 3620 S Vermont Ave,KAP 210, Los Angeles, CA 90089 USA
基金
美国能源部;
关键词
Non-linear finite element analysis; Blast loading; CONWEP; Containment structures; Concrete dry casks; FINITE-ELEMENT-ANALYSIS; PLASTIC-DAMAGE MODEL; CONCRETE; IMPACT; BEHAVIOR;
D O I
10.1016/j.anucene.2021.108155
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Dry storage casks are the most common form of spent nuclear fuel (SNF) storage in the United States. An explosion near a spent nuclear storage facility poses a serious public risk due to the potential of radioactive leakage. In this study, for the first time, the structural performance of vertical steel-concrete-steel sandwich (SCSS) and reinforced concrete (RC) casks under blast loading scenarios is studied using explicit finite element simulations considering material and geometric nonlinearity and strain rate effects. The response of the cask is investigated in terms of stress levels, deformations, and peak accelerations. The conventional weapons (CONWEP) model was used to induce a blast load on the structure at varying blast charges. The accelerations experienced by the canister and the fuel assemblies, which are critical for design are estimated. The inherent vibration damping characteristics of the cask are evaluated, and a novel damper configuration is proposed to improve the energy dissipation capacity of the system. The results showed that the general integrity of the cask could be preserved in the presence of a thick reinforced concrete layer. However, due to the lack of a damping mechanism, the blast wave can propagate through the system and result in very large accelerations in the canister and the fuel assemblies. Results also revealed that the SCSS configuration has a more ductile response compared to the RC design. The results of this study could be used for the safety evaluation and design optimization of current casks in service and other cylindrical composite containment structures. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:14
相关论文
共 49 条
  • [1] American Society of Materials Testing (ASTM), 2016, A615A615M16 ASTM INT
  • [2] [Anonymous], 2019, LS-DYNA theory manual
  • [3] [Anonymous], 2014, Building Code Requirements for Structural Concrete (ACI 318-14) and Commentary (ACI 318R-14). ACI 318-14
  • [4] [Anonymous], 2018, A572A572M18 ASTM INT
  • [5] [Anonymous], 1957, Brown Univ. Div. Appl. Math.
  • [6] AREVA, 2007, US EPR FUEL ASS MECH
  • [7] ASTM, 2014, SSTANDARD SPECIFICAT
  • [8] Baker W.E., 1973, Explosions in Air
  • [9] Becker R., 2020, SOME NUMERICAL CONSI
  • [10] IMPACT BEHAVIOR OF PLAIN CONCRETE LOADED IN UNIAXIAL COMPRESSION
    BISCHOFF, PH
    PERRY, SH