Quantitative depth profiling of Si1-xGex structures by time-of-flight secondary ion mass spectrometry and secondary neutral mass spectrometry

被引:8
作者
Drozdov, M. N. [1 ,2 ]
Drozdov, Y. N. [1 ,2 ]
Csik, A. [3 ]
Novikov, A. V. [1 ,2 ]
Vad, K. [3 ]
Yunin, P. A. [1 ,2 ]
Yurasov, D. V. [1 ,2 ]
Belykh, S. F. [4 ]
Gololobov, G. P. [5 ]
Suvorov, D. V. [5 ]
Tolstogouzov, A. [5 ,6 ]
机构
[1] RAS, IPM, Nizhnii Novgorod 603950, Russia
[2] Lobachevski Nizhniy Novgorod State Univ, Nizhnii Novgorod 603950, Russia
[3] Hungarian Acad Sci, Inst Nucl Res INR, Bem Ter 18-C, H-4026 Debrecen, Hungary
[4] MATI Russian State Technol Univ, Orshanskaya Str 3, Moscow 121552, Russia
[5] Ryazan State Radio Engn Univ, Gagarin Str 59-1, Ryazan 390005, Russia
[6] Univ Nova Lisboa, Ctr Phys & Technol Res CeFITec, Dept Fis, Fac Ciencias & Tecnol FCT, P-2829516 Caparica, Portugal
基金
俄罗斯基础研究基金会;
关键词
Electron-gas secondary neutral mass spectrometry (SNMS); Mixing-roughness-information depth model (MRI); Reference samples; Si1-xGex structures; Sputter depth profiling; Time-of-flight secondary ion mass spectrometry (TOF-SIMS); TOF-SIMS; SIGE COMPOSITION; NEGATIVE MODE; QUANTIFICATION; MATRIX; GE; RESOLUTION; GERMANIUM; HETEROSTRUCTURES; MULTILAYER;
D O I
10.1016/j.tsf.2016.03.049
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Quantification of Ge in Si1-xGex structures (0.092 <= x <= 0.78) was carried out by time-of-flight secondary ion mass spectrometry (TOF-SIMS) and electron-gas secondary neutral mass spectrometry (SNMS). A good linear correlation (R-2 > 0.9997) of the intensity ratios of secondary ions GeCs2+/SiCs2+ and Ge-74(-)/Si-30(-) and post-ionized sputtered neutrals Ge-70(+)/Si-28(+) with Ge concentration was obtained. The calibration data were used for quantitative depth profiling of [10 x (12.3 nm Si0.63Ge0.37/34 nm Si)] structures on Si. Satisfactory compliance of the quantified Ge concentration in SiGe layers with the values obtained by high-resolution X-ray diffraction was revealed for both techniques. SIMS and SNMS experimental profiles were fitted using Hofmann's mixing-roughness-information depth (MRI) model. In the case of TOF-SIMS, the quality of the reconstruction was better than for SNMS since not only the progressing roughening, but also the crater effect and other processes unaccounted in the MRI simulation could have a significant impact on plasma sputter depth profiling. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:25 / 31
页数:7
相关论文
共 50 条
  • [21] Sensitive and multiplexed analysis of aflatoxins using time-of-flight secondary ion mass spectrometry
    Ahn, Jang-Hyuk
    Jeong, Young-Su
    Lee, Tae Geol
    Kim, Young-Pil
    Kim, Hak-Sung
    BIOCHIP JOURNAL, 2012, 6 (01) : 34 - 40
  • [22] Improved 3D-imaging of a sirolimus/probucol eluting stent coating using laser postionization secondary neutral mass spectrometry and time-of-flight secondary ion mass spectrometry
    Pelster, Andreas
    Tyler, Bonnie J.
    Koersgen, Martin
    Kassenboehmer, Rainer
    Peterson, Richard E.
    Stoever, Michael
    Unger, Wolfgang E. S.
    Arlinghaus, Heinrich F.
    BIOINTERPHASES, 2016, 11 (04)
  • [23] Sensitive and multiplexed analysis of aflatoxins using time-of-flight secondary ion mass spectrometry
    Jang-Hyuk Ahn
    Young-Su Jeong
    Tae Geol Lee
    Young-Pil Kim
    Hak-Sung Kim
    BioChip Journal, 2012, 6 : 34 - 40
  • [24] Forensic Characterization of Lipsticks Using Time-of-Flight Secondary Ion Mass Spectrometry
    Lee, Jihye
    Lee, Yeonhee
    JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 76 (07) : 854 - 867
  • [25] Structural characterization of various ionomers by time-of-flight secondary ion mass spectrometry
    Lee, Y
    Han, S
    Kwon, MH
    Lim, H
    Kim, YS
    Chun, H
    Kim, JS
    APPLIED SURFACE SCIENCE, 2003, 203 : 875 - 879
  • [26] Introduction to time-of-flight secondary ion mass spectrometry application in chromatographic analysis
    Orinák, A
    Arlinghaus, HF
    Vering, G
    Orináková, R
    Hellweg, S
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1084 (1-2) : 113 - 118
  • [27] Depth profiling cross-linked poly(methyl methacrylate) films: a time-of-flight secondary ion mass spectrometry approach
    Naderi-Gohar, Soheila
    Huang, Kevin M. H.
    Wu, Yiliang
    Lau, Woon Ming
    Nie, Heng-Yong
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2017, 31 (04) : 381 - 388
  • [28] Analysis of adsorbed proteins by static time-of-flight secondary ion mass spectrometry
    Wagner, MS
    Castner, DG
    APPLIED SURFACE SCIENCE, 2004, 231 : 366 - 376
  • [29] Analysis of liposome model systems by time-of-flight secondary ion mass spectrometry
    Lovric, Jelena
    Keighron, Jacqueline D.
    Angerer, Tina B.
    Li, Xianchan
    Malmberg, Per
    Fletcher, John S.
    Ewing, Andrew G.
    SURFACE AND INTERFACE ANALYSIS, 2014, 46 : 74 - 78
  • [30] Surface studies of heterogeneous catalysts by time-of-flight secondary ion mass spectrometry
    Grams, Jacek
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2010, 16 (03) : 453 - 461