Rapid Diagnostic Test Kit for Point-of-Care Cerebrospinal Fluid Leak Detection

被引:9
|
作者
Bradbury, Daniel W. [1 ]
Kita, Ashley E. [2 ]
Hirota, Kensuke [1 ]
St John, Maie A. [1 ,2 ,3 ,4 ]
Kamei, Daniel T. [1 ]
机构
[1] Univ Calif Los Angeles, Henry Samueli Sch Engn & Appl Sci, Dept Bioengn, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Head & Neck Surg, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, David Geffen Sch Med, Jonsson Comprehens Canc Ctr, Los Angeles, CA 90095 USA
[4] Univ Calif Los Angeles, David Geffen Sch Med, Head & Neck Canc Program, Los Angeles, CA 90095 USA
来源
SLAS TECHNOLOGY | 2020年 / 25卷 / 01期
基金
美国国家卫生研究院;
关键词
cerebrospinal fluid leak; lateral-flow immunoassay; point of care; beta-trace protein; rapid diagnostic test; BETA-TRACE PROTEIN; COMPLICATIONS; OTORRHEA; MARKER; BETA(2)-TRANSFERRIN; TRANSFERRIN; MENINGITIS; RHINORRHEA;
D O I
10.1177/2472630319877377
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cerebrospinal fluid (CSF) leaks can occur when there is communication between the intracranial cavities and the external environment. They are a common and serious complication of numerous procedures in otolaryngology, and if not treated, persistent leaks can increase a patient's risk of developing life-threatening complications such as meningitis. As it is not uncommon for patients to exhibit increased secretions postoperatively, distinguishing normal secretions from those containing CSF can be difficult. Currently, there are no proven, available tests that allow a medical provider concerned about a CSF leak to inexpensively, rapidly, and noninvasively rule out the presence of a leak. The gold standard laboratory-based test requires that a sample be sent to a tertiary site for analysis, where days to weeks may pass before results return. To address this, our group recently developed a semiquantitative, barcode-style lateral-flow immunoassay (LFA) for the quantification of the beta-trace protein, which has been reported to be an indicator of the presence of CSF leaks. In the work presented here, we created a rapid diagnostic test kit composed of our LFA, a collection swab, dilution buffers, disposable pipettes, and instructions. Validation studies demonstrated excellent predictive capabilities of this kit in distinguishing between clinical specimens containing CSF and those that did not. Our diagnostic kit for CSF leak detection can be operated by an untrained user, does not require any external equipment, and can be performed in approximately 20 min, making it well suited for use at the point of care. This kit has the potential to transform patient outcomes.
引用
收藏
页码:67 / 74
页数:8
相关论文
共 50 条
  • [1] Point-of-Care Cerebrospinal Fluid Detection
    Kita, Ashley E.
    Bradbury, Daniel W.
    Taylor, Zachary D.
    Kamei, Daniel T.
    St John, Maie A.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2018, 159 (05) : 824 - 829
  • [2] Point-of-care detection of lactate in cerebrospinal fluid
    C. Stephani
    A. H. K. Choi
    O. Moerer
    Intensive Care Medicine Experimental, 9
  • [3] Point-of-care detection of lactate in cerebrospinal fluid
    Stephani, C.
    Choi, A. H. K.
    Moerer, O.
    INTENSIVE CARE MEDICINE EXPERIMENTAL, 2021, 9 (01)
  • [4] Sample-dependent diagnostic accuracy of prostaglandin D synthase in cerebrospinal fluid leak
    Morell-Garcia, Daniel
    Miguel Bauca, Josep
    Pilar Sastre, M.
    Yanez, Aina
    Llompart, Isabel
    CLINICAL BIOCHEMISTRY, 2017, 50 (1-2) : 27 - 31
  • [5] A Novel Point-of-Care Rapid Diagnostic Test for Screening Individuals for Antibody Deficiencies
    Shirli Israeli
    Allison Golden
    Melissa Atalig
    Najla Mekki
    Afef Rais
    Helen Storey
    Mohamed-Ridha Barbouche
    Roger Peck
    Journal of Clinical Immunology, 2022, 42 : 394 - 403
  • [6] A Novel Point-of-Care Rapid Diagnostic Test for Screening Individuals for Antibody Deficiencies
    Israeli, Shirli
    Golden, Allison
    Atalig, Melissa
    Mekki, Najla
    Rais, Afef
    Storey, Helen
    Barbouche, Mohamed-Ridha
    Peck, Roger
    JOURNAL OF CLINICAL IMMUNOLOGY, 2022, 42 (02) : 394 - 403
  • [7] Cerebrospinal Fluid Glucose Measurement at Point-of-Care
    Thomas, Steven
    Halstead, Anne Catherine
    Douglas, M. Joanne
    Villar, Giselle
    Saran, Simrat
    Kozak, Elvira
    POINT OF CARE, 2012, 11 (02): : 73 - 76
  • [8] Evaluation of a point-of-care immunoassay test kit 'StrongStep' for cryptococcal antigen detection
    Mpoza, Edward
    Mukaremera, Liliane
    Kundura, Didas Atwebembere
    Akampurira, Andrew
    Luggya, Tonny
    Tadeo, Kiiza Kandole
    Pastick, Katelyn A.
    Bridge, Sarah C.
    Tugume, Lillian
    Kiggundu, Reuben
    Musubire, Abdu K.
    Williams, Darlisha A.
    Muzoora, Conrad
    Nalintya, Elizabeth
    Rajasingham, Radha
    Rhein, Joshua
    Boulware, David R.
    Meya, David B.
    Abassi, Mahsa
    PLOS ONE, 2018, 13 (01):
  • [9] Cut-off value for β-trace protein (β-TP) as a rapid diagnostic of cerebrospinal fluid (CSF) leak detection
    Almela, Maria-Teresa
    Navarro-Zaragoza, Javier
    Laorden, Maria-Luisa
    Sanchez-Celemin, Fernando
    Almela, Pilar
    LARYNGOSCOPE INVESTIGATIVE OTOLARYNGOLOGY, 2023, 8 (05): : 1233 - 1239
  • [10] Accuracy of a multispecies rapid diagnostic test kit for detection of malarial parasite at the point of care in a low endemicity region
    Meena, M.
    Joshi, D.
    Joshi, R.
    Sridhar, S.
    Waghdhare, S.
    Gangane, N.
    Kalantri, S. P.
    TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 2009, 103 (12) : 1237 - 1244