Effect of gate choice on backscatter difference measurements of cancellous bone

被引:16
|
作者
Hoffmeister, Brent K. [1 ]
Viano, Ann M. [1 ]
Fairbanks, Luke C. [1 ]
Ebron, Sheldon C. [1 ]
McPherson, Joseph A. [1 ]
Huber, Matthew T. [1 ]
机构
[1] Rhodes Coll, Dept Phys, Memphis, TN 38112 USA
来源
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA | 2017年 / 142卷 / 02期
基金
美国国家卫生研究院;
关键词
SPECTRAL CENTROID SHIFT; ULTRASONIC BACKSCATTER; FREQUENCY-DEPENDENCE; IN-VIVO; QUANTITATIVE ULTRASOUND; MINERAL DENSITY; TRABECULAR BONE; OSTEOPOROSIS; METHODOLOGY; ATTENUATION;
D O I
10.1121/1.4996140
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A variety of ultrasonic techniques have been developed to detect changes in bone caused by osteoporosis. One approach, called the backscatter difference technique, analyzes the power difference between two different portions of a backscatter signal. Analysis gates with a certain delay tau(d), width tau(w), and separation ss are used to define portions of the backscatter signal for analysis. The goal of the present study was to investigate how different choices of tau(d), tau(w), and tau(s) affect four backscatter difference parameters: the normalized mean of the backscatter difference (nMBD), the normalized slope of the backscatter difference (nSBD), the normalized intercept of the backscatter difference (nIBD), and the normalized backscatter amplitude ratio (nBAR). Backscatter measurements were performed on 54 cube shaped specimens of human cancellous bone. nMBD, nSBD, nIBD, and nBAR were determined for 34 different combinations of tau(d), tau(w), and tau(s) for each specimen. nMBD and nBAR demonstrated the strongest correlations with apparent bone density (0.48 <= R-s <= 0.90). Generally, the correlations were found to improve as tau(w) + tau(s) was increased and as tau(d) was decreased. Among the four backscatter difference parameters, the measured values of nMBD were least sensitive to gate choice (< 16%). (C) 2017 Acoustical Society of America.
引用
收藏
页码:540 / 550
页数:11
相关论文
共 50 条
  • [1] Effect of the cortex on ultrasonic backscatter measurements of cancellous bone
    Hoffmeister, Brent K.
    Holt, Andrew P.
    Kaste, Sue C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (19): : 6243 - 6255
  • [2] Effect of transducer position on ultrasonic backscatter measurements of cancellous bone
    Hoffmeister, Brent K.
    Lawler, Blake C.
    Viano, Ann M.
    Mobley, Joel
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2023, 154 (05): : 2858 - 2868
  • [3] Backscatter-difference Measurements of Cancellous Bone Using an Ultrasonic Imaging System
    Hoffmeister, Brent K.
    Smathers, Morgan R.
    Miller, Catherine J.
    McPherson, Joseph A.
    Thurston, Cameron R.
    Spinolo, P. Luke
    Lee, Sang-Rok
    ULTRASONIC IMAGING, 2016, 38 (04) : 285 - 297
  • [5] Ultrasonic backscatter difference measurements of cancellous bone from the human femur: Relation to bone mineral density and microstructure
    Hoffmeister, Brent K.
    Viano, Ann M.
    Huang, Jinsong
    Fairbanks, Luke C.
    Ebron, Sheldon C.
    Moore, Joshua T.
    Ankersen, Jordan P.
    Huber, Matthew T.
    Diaz, Abel A.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2018, 143 (06): : 3642 - 3653
  • [6] Anisotropy of attenuation and backscatter in cancellous bone
    Wear, KA
    2000 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2000, : 1325 - 1328
  • [7] Ultrasonic backscatter and attenuation of cancellous bone
    Deligianni, D
    Apostolopoulos, K
    ADVANCES IN SCATTERING AND BIOMEDICAL ENGINEERING, PROCEEDINGS, 2004, : 504 - 511
  • [8] Influence of the precision of spectral backscatter measurements on the estimation of scatterers size in cancellous bone
    Padilla, F.
    Jenson, F.
    Laugier, P.
    ULTRASONICS, 2006, 44 : E57 - E60
  • [9] Effect of Spectral Estimation on Ultrasonic Backscatter Parameters in Measurements of Cancellous Bones
    Li, Boyi
    Xu, Feng
    Liu, Chengcheng
    Li, Dan
    Le, Lawrence H.
    Ta, Dean
    Wang, Weiqi
    IEEE ACCESS, 2019, 7 : 83034 - 83045
  • [10] Numerical investigation of ultrasound reflection and backscatter measurements in cancellous bone on various receiving areas
    Hosokawa, Atsushi
    ULTRASONICS, 2014, 54 (05) : 1237 - 1244