Sixty-four slice CT evaluation of aortic stenosis using planimetry of the aortic valve area

被引:71
作者
Feuchtner, Gudrun M.
Mueller, Silvana
Bonatti, Johannes
Schachner, Thomas
Velik-Salchner, Corinna
Pachinger, Otmar
Dichtl, Wolfgang
机构
[1] Innsbruck Med Univ, Clin Dept Radiol 2, A-6020 Innsbruck, Austria
[2] Innsbruck Med Univ, Clin Dept Cardiol, A-6020 Innsbruck, Austria
[3] Innsbruck Med Univ, Clin Dept Cardiac Surg, A-6020 Innsbruck, Austria
[4] Innsbruck Med Univ, Clin Dept Anesthesia & Intens Care Med, A-6020 Innsbruck, Austria
关键词
aortic stenosis; echocardiography; 64-slice CT; planimetry;
D O I
10.2214/AJR.07.2069
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to evaluate planimetry of the aortic valve area with 64-slice CT in comparison with transthoracic echocardiography (TTE) and transesophageal echocardiography ( TEE) in patients with aortic stenosis. MATERIALS AND METHODS. Thirty-six patients with aortic valve disease referred for coronary 64-slice CT angiography were examined. Planimetry of the aortic valve area with 64-slice CT was compared with TTE using the Doppler continuity equation for calculation of the aortic valve area and with planimetric measurement of the aortic valve area using TEE. RESULTS. Planimetry of the aortic valve area with CT (1.11 +/- 0.42 cm(2)) showed a good correlation with TTE (1.05 +/- 0.42 cm(2)) ( r = 0.88, p < 0.001) in 32 patients and a good correlation with TEE (1.41 +/- 1.61 cm(2)) ( r = 0.99, p < 0.0001) in 10 patients. The mean and maximum transvalvular pressure gradients were correlated with the aortic valve area as measured with CT ( r = - 0.68, p = 0.0001; and r = - 0.67, p = 0.0001, respectively). Beta-blockers were not given ( mean heart rate, 62.5 +/- 10.7 beats per minute). CONCLUSION. MDCT allows accurate planimetry of the aortic valve area in patients with aortic stenosis. In patients referred for 64-slice CT coronary angiography, concomitant aortic stenosis can be identified and evaluated.
引用
收藏
页码:197 / 203
页数:7
相关论文
共 22 条
[1]   Aortic stenosis: Comparative evaluation of 16-detector row CT and echocardiography [J].
Alkadhi, H ;
Wildermuth, S ;
Plass, A ;
Bettex, D ;
Baumert, B ;
Leschka, S ;
Desbiolles, LM ;
Marincek, B ;
Boehm, T .
RADIOLOGY, 2006, 240 (01) :47-55
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Guidelines for the management of patients with valvular heart disease - Executive summary - A report of the American College of Cardiology American Heart Association task force on practice guidelines (committee on management of patients with valvular heart disease) [J].
Bonow, RO ;
Carabello, B ;
de Leon, AC ;
Edmunds, LH ;
Fedderly, BJ ;
Freed, MD ;
Gaasch, WH ;
McKay, CR ;
Nishimura, RA ;
O'Gara, PT ;
O'Rourke, RA ;
Rahimtoola, SH ;
Ritchie, JL ;
Cheitlin, MD ;
Eagle, KA ;
Gardner, TJ ;
Garson, A ;
Gibbons, RJ ;
Russell, RO ;
Ryan, TJ ;
Smith, SC .
CIRCULATION, 1998, 98 (18) :1949-1984
[4]   Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer [J].
Brenner, DJ .
RADIOLOGY, 2004, 231 (02) :440-445
[5]   Intravenous contrast material administration at 16-detector row helical CT coronary angiography: Test bolus versus bolus-tracking technique [J].
Cademartiri, F ;
Nieman, K ;
van der Lugt, A ;
Raaijmakers, RH ;
Mollet, N ;
Pattynama, PMT ;
de Feyter, PJ ;
Krestin, GP .
RADIOLOGY, 2004, 233 (03) :817-823
[6]   VALIDATION AND APPLICATIONS OF INDEXED AORTIC PROSTHETIC VALVE AREAS CALCULATED BY DOPPLER ECHOCARDIOGRAPHY [J].
DUMESNIL, JG ;
HONOS, GN ;
LEMIEUX, M ;
BEAUCHEMIN, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (03) :637-643
[7]   Multislice computed tomography for detection of patients with aortic valve stenosis and quantification of severity [J].
Feuchtner, GM ;
Dichtl, W ;
Friedrich, GJ ;
Frick, M ;
Alber, H ;
Schachner, T ;
Bonatti, J ;
Matlouhi, A ;
Frede, T ;
Pachinger, O ;
Nedden, DZ ;
Müller, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (07) :1410-1417
[8]   New technical developments in multislice CT, part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac Imaging [J].
Flohr, T ;
Bruder, H ;
Stierstorfer, K ;
Simon, J ;
Schaller, S ;
Ohnesorge, B .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (08) :1022-1027
[9]   Performance evaluation of a 64-slice CT system with z-flying focal spot [J].
Flohr, T ;
Stierstorfer, K ;
Raupach, R ;
Ulzheimer, S ;
Bruder, H .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (12) :1803-1810
[10]   Radiation dose estimates from cardiac multislice computed tomography in daily practice -: Impact of different scanning protocols on effective dose estimates [J].
Hausleiter, J ;
Meyer, T ;
Hadamitzky, M ;
Huber, E ;
Zankl, M ;
Martinoff, S ;
Kastrati, A ;
Schömig, A .
CIRCULATION, 2006, 113 (10) :1305-1310