摘要
This study investigated the punching shear behavior of two-way concrete slabs with glass-fiber-reinforced polymer (GFRP) bars as flexural reinforcement and FRP stirrups (glass or carbon) as shear reinforcement. A total of 10 full-scale interior slab-column specimens measuring 2,500 x 2,500 mm, with thicknesses of either 200 or 350 mm, and 300 x 300-mm square column stubs were fabricated and tested under monotonic concentric loading until failure. These tests aimed at investigating the behavior of GFRP-reinforced two-way concrete slabs reinforced with FRP stirrups as shear reinforcement and evaluating their contribution to the punching shear capacity. The investigated parameters were the flexural reinforcement ratio and the shear reinforcement type (glass FRP and carbon FRP stirrups) and ratio. The test results revealed that using FRP stirrups as shear reinforcement increased the punching shear strength and deformation capacity of the test slabs. The increased punching shear strength and deformation capacity were proportional to the flexural- and shear-reinforcement ratios. In addition, the performance was enhanced by reducing the brittleness of the specimens when FRP stirrups were used as shear reinforcement. (C) 2014 American Society of Civil Engineers.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Punching Shear Strengthening of Two-Way Flat Slabs with CFRP Grids
    Meisami, M. Hasan
    Mostofinejad, Davood
    Nakamura, Hikaru
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2014, 18 (02)
  • [22] Development of FRP Shear Bolts for Punching Shear Retrofit of Reinforced Concrete Slabs
    Lawler, Nicholas
    Polak, Maria Anna
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2011, 15 (04) : 591 - 601
  • [23] Prefabricated punching shear reinforcement for reinforced concrete slabs
    Anon
    Concrete (London), 2001, 35 (06):
  • [24] Two-Way Shear Resistance of FRP Reinforced-Concrete Slabs: Data and a Comparative Study
    Aslam, Fahid
    AbdelMongy, Mohamed
    Alzara, Majed
    Ibrahim, Taha
    Deifalla, Ahmed Farouk
    Yosri, Ahmed M.
    POLYMERS, 2022, 14 (18)
  • [25] Two-parameter kinematic theory for punching shear in reinforced concrete slabs with shear reinforcement
    Kueres, Dominik
    Schmidt, Philipp
    Hegger, Josef
    ENGINEERING STRUCTURES, 2019, 181 (216-232) : 216 - 232
  • [26] Minimum shear reinforcement for thick plates and two-way slabs
    Rizk, E.
    Marzouk, H.
    ENGINEERING STRUCTURES, 2013, 46 : 1 - 13
  • [27] Effect of flexural and shear reinforcement on the punching behavior of reinforced concrete flat slabs
    Mabrouk, Rasha T. S.
    Bakr, Amr
    Abdalla, Hany
    ALEXANDRIA ENGINEERING JOURNAL, 2017, 56 (04) : 591 - 599
  • [28] Punching shear strengthening of two-way flat slabs using CFRP rods
    Meisami, M. Hasan
    Mostofinejad, Davood
    Nakamura, Hikaru
    COMPOSITE STRUCTURES, 2013, 99 : 112 - 122
  • [29] Does the use of FRP reinforcement change the one-way shear behavior of reinforced concrete slabs?
    Hoult, N. A.
    Sherwood, E. G.
    Bentz, E. C.
    Collins, M. P.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2008, 12 (02) : 125 - 133
  • [30] Two-parameter kinematic theory for punching shear in reinforced concrete slabs without shear reinforcement
    Kueres, Dominik
    Hegger, Josef
    ENGINEERING STRUCTURES, 2018, 175 : 201 - 216