Availability and safety assessment of infrared neural stimulation at high repetition rate through an implantable optrode

被引:2
|
作者
Wan, Yaqin [1 ]
Wang, Meiqun [2 ,3 ]
Zhang, Shaorong [2 ,3 ]
Xie, Bingbin [2 ,3 ]
机构
[1] Nanchang Univ, Out Patient Dept, Affiliated Hosp 2, 1 Minde Rd, Nanchang 330006, Jiangxi, Peoples R China
[2] Nanchang Univ, Dept Otolaryngol Head & Neck Surg, Affiliated Hosp 2, 1 Minde Rd, Nanchang 330006, Jiangxi, Peoples R China
[3] Jiangxi Biomed Engn Res Ctr Auditory Res, 1 Minde Rd, Nanchang 330006, Jiangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Infrared neural stimulation; implantable optrode; cochlear implant; spiral ganglion neuron; optical stimulation; OPTICAL STIMULATION; GANGLION NEURONS; DAMAGE THRESHOLD; AUDITORY NEURONS; PULSE DURATION; COCHLEA; HEARING; TRANSIENT;
D O I
10.1142/S1793545821500140
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An implantable optrode with micro-thermal detectors was designed to investigate the availability and safety of INS using high repetition rates. Optical auditory brainstem responses (oABRs) were recorded in normal-hearing guinea pigs, and the energy thresholds, pulse durations, and amplitudes evoked by the varied stimulus repetitions were analyzed. Stable oABRs could be evoked through INS even as the repetition rate of stimulation reached 19kHz. The energy threshold of oABRs was elevated, the amplitudes decreased as pulse durations increased and repetition rates were higher, and the latencies were delayed as the pulse durations increased. The temperature variation curves on the site of stimulation significantly increased as the pulse duration increased to 400 mu s. INS elevated the temperature around the stimulus site area via thermal accumulation during radiation, especially when higher repetition stimuli were used. Our results demonstrate that high repetition infrared stimulations can safely evoke stable and available oABRs in normal-hearing guinea pigs.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Optrode Arrays for Infrared Neural Stimulation
    Abaya, T. V. F.
    Diwekar, M.
    Blair, S.
    Tathireddy, P.
    Rieth, L.
    Clark, G. A.
    Solzbacher, F.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS IX, 2013, 8565
  • [2] Optimization of an optrode microdevice for infrared neural stimulation
    Boros, O. C.
    Horvath, A. C.
    Beleznai, S.
    Sepsi, O.
    Csosz, D.
    Fekete, Z.
    Koppa, P.
    APPLIED OPTICS, 2019, 58 (14) : 3870 - 3876
  • [3] Optical and thermal modeling of an optrode microdevice for infrared neural stimulation
    Boros, O. C.
    Horvath, A. C.
    Beleznai, S.
    Sepsi, O.
    Lenk, S.
    Fekete, Z.
    Koppa, P.
    APPLIED OPTICS, 2018, 57 (24) : 6952 - 6957
  • [4] A CMOS-based Neural Implantable Optrode for Optogenetic Stimulation and Electrical Recording
    Zhao, Hubin
    Dehkhoda, Fahimeh
    Ramezani, Reza
    Sokolov, Danil
    Degenaar, Patrick
    Liu, Yan
    Constandinou, Timothy
    2015 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2015, : 286 - 289
  • [5] Characterization of a 3D optrode array for infrared neural stimulation
    Abaya, T. V. F.
    Diwekar, M.
    Blair, S.
    Tathireddy, P.
    Rieth, L.
    Clark, G. A.
    Solzbacher, F.
    BIOMEDICAL OPTICS EXPRESS, 2012, 3 (09): : 2200 - 2219
  • [6] Influence of radiant exposure and repetition rate in infrared neural stimulation with near-infrared lasers
    Mohammad Javad Alemzadeh-Ansari
    Mohammad Ali Ansari
    Mahdi Zakeri
    Majid Haghjoo
    Lasers in Medical Science, 2019, 34 : 1555 - 1566
  • [7] Influence of radiant exposure and repetition rate in infrared neural stimulation with near-infrared lasers
    Alemzadeh-Ansari, Mohammad Javad
    Ansari, Mohammad Ali
    Zakeri, Mahdi
    Haghjoo, Majid
    LASERS IN MEDICAL SCIENCE, 2019, 34 (08) : 1555 - 1566
  • [8] Optical Characterization of the Utah Slant Optrode Array for Intrafascicular Infrared Neural Stimulation
    Abaya, T. V. F.
    Diwekar, M.
    Blair, S.
    Tathireddy, P.
    Rieth, L.
    Clark, G. A.
    Solzbacher, F.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS VIII, PTS 1 AND 2, 2012, 8207
  • [9] An Implantable Optrode with Self-diagnostic Function in 0.35μm CMOS for Optical Neural Stimulation
    Zhao, Hubin
    Sokolov, Danil
    Degenaar, Patrick
    2014 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2014, : 244 - 247
  • [10] Infrared Neural Stimulation: Influence of Stimulation Site Spacing and Repetition Rates on Heating
    Thompson, Alexander C.
    Wade, Scott A.
    Pawsey, Nicholas C.
    Stoddart, Paul R.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (12) : 3534 - 3541