Patient-specific reconstructed anatomies and computer simulations are fundamental for selecting medical device treatment: application to a new percutaneous pulmonary valve

被引:38
作者
Capelli, Claudio [1 ,2 ]
Taylor, Andrew M. [1 ,2 ]
Migliavacca, Francesco [3 ]
Bonhoeffer, Philipp [1 ]
Schievano, Silvia [1 ,2 ]
机构
[1] UCL Inst Child Hlth, Cardiovasc Unit, London WC1N 3JH, England
[2] Great Ormond St Hosp Sick Children, London WC1N 3JH, England
[3] Politecn Milan, Dept Struct Engn, Lab Biol Struct Mech, I-20133 Milan, Italy
来源
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES | 2010年 / 368卷 / 1921期
基金
英国工程与自然科学研究理事会;
关键词
patient specific; finite element; stent graft; percutaneous pulmonary valve implantation; VENTRICULAR OUTFLOW TRACT; VIRTUAL PHYSIOLOGICAL HUMAN; IMPLANTATION; STENT; CONSEQUENCES; REPLACEMENT; MECHANICS; BEHAVIOR; CONDUIT; IMPACT;
D O I
10.1098/rsta.2010.0088
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Nowadays, percutaneous pulmonary valve implantation is a successful alternative to surgery for patients requiring treatment of pulmonary valve dysfunction. However, owing to the wide variety of implantation site morphology, size and dynamics, only about 15 per cent of cases are suitable for current devices. In order to increase the number of patients who could benefit from minimally invasive procedures, a new valved stent graft for percutaneous implantation has been designed recently. In this study, patient-specific computational analyses have been applied to investigate the suitability of new device designs, using real data from 62 patients who had undergone surgical pulmonary valve replacement. Magnetic resonance images of these patients before surgery were elaborated using imaging post-processing software to reconstruct the three-dimensional volume of each patient's implantation site. Three stent designs were created and tested in these patient out flow tracts using finite-element simulations: stent graft SG1 resembles the first device tested in animals; stent graft SG2 is a custom device tailored for a specific patient morphology; and stent graft SG3 represents a hypothetical larger device. The three devices showed an implantation success rate of 37 per cent, 42 per cent and 63 per cent, respectively. Using patient specific simulations, we have shown that a percutaneous approach with these new devices may be possible for many patients who are currently referred for surgery. Furthermore, when the new devices become available, the methodologies described may help clinicians in the decision-making process, by enabling virtual implantation prior to the actual procedure.
引用
收藏
页码:3027 / 3038
页数:12
相关论文
共 28 条
[1]  
*AB, 2007, AB AN US MAN V 6 7 E, V4
[2]   Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction [J].
Bonhoeffer, P ;
Boudjemline, Y ;
Saliba, Z ;
Merckx, J ;
Aggoun, Y ;
Bonnet, D ;
Acar, P ;
Le Bidois, J ;
Sidi, D ;
Kachaner, J .
LANCET, 2000, 356 (9239) :1403-1405
[3]  
BONHOEFFER P, 2009, WORKSH IPC ISHAC JOI
[4]  
Bonhoeffer P, 2008, CIRCULATION, V118, pS812
[5]   Assessment of tissue prolapse after balloon-expandable stenting: Influence of stent cell geometry [J].
Capelli, Claudio ;
Gervaso, Francesca ;
Petrini, Lorenza ;
Dubini, Gabriele ;
Migliavacca, Francesco .
MEDICAL ENGINEERING & PHYSICS, 2009, 31 (04) :441-447
[6]   Device Erosion [J].
Carroll, John D. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 73 (07) :931-932
[7]   Physiological and clinical consequences of relief of right ventricular outflow tract obstruction late after repair of congenital heart defects [J].
Coats, L ;
Khambadkone, S ;
Derrick, G ;
Sridharan, S ;
Schievano, S ;
Mist, B ;
Jones, R ;
Deanfield, JE ;
Pellerin, D ;
Bonhoeffer, P ;
Taylor, AM .
CIRCULATION, 2006, 113 (17) :2037-2044
[8]   Physiological consequences of percutaneous pulmonary valve implantation: the different behaviour of volume- and pressure-overloaded ventricles [J].
Coats, Louise ;
Khambadkone, Sachin ;
Derrick, Graham ;
Hughes, Marina ;
Jones, Rod ;
Mist, Bryan ;
Pellerin, Denis ;
Marek, Jan ;
Deanfleld, John E. ;
Bonhoeffer, Philipp ;
Taylor, Andrew M. .
EUROPEAN HEART JOURNAL, 2007, 28 (15) :1886-1893
[9]   Realistic finite element-based stent design: The impact of balloon folding [J].
De Beule, Matthieu ;
Mortier, Peter ;
Carlier, Stphane G. ;
Verhegghe, Benedict ;
Van Impe, Rudy ;
Verdonck, Pascal .
JOURNAL OF BIOMECHANICS, 2008, 41 (02) :383-389
[10]   The EuroPhysiome, STEP and a roadmap for the virtual physiological human [J].
Fenner, J. W. ;
Brook, B. ;
Clapworthy, G. ;
Coveney, P. V. ;
Feipel, V. ;
Gregersen, H. ;
Hose, D. R. ;
Kohl, P. ;
Lawford, P. ;
McCormack, K. M. ;
Pinney, D. ;
Thomas, S. R. ;
Jan, S. Van Sint ;
Waters, S. ;
Viceconti, M. .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2008, 366 (1878) :2979-2999