Accuracy of a New Robotically Assisted Technique for Total Knee Arthroplasty: A Cadaveric Study

被引:102
作者
Parratte, Sebastien [1 ,2 ]
Price, Andrew J. [3 ]
Jeys, Lee M. [4 ]
Jackson, William F. [3 ]
Clarke, Henry D. [5 ]
机构
[1] Int Knee & Joint Ctr, Adult Reconstruct Surg, Abu Dhabi, U Arab Emirates
[2] Aix Marseille Univ, Inst Locomot, Adult Reconstruct Surg, Marseille, France
[3] Nuffield Orthopaed Ctr, Adult Reconstruct Surg, Oxford, England
[4] Royal Orthopaed Hosp, Adult Reconstruct Surg, Birmingham, W Midlands, England
[5] Mayo Clin, Adult Reconstruct Surg, Phoenix, AZ USA
关键词
TKA; robotic surgery; accuracy; computer-assisted surgery; in vitro; ALIGNMENT; REPLACEMENT; NAVIGATION;
D O I
10.1016/j.arth.2019.06.040
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Although the utility of robotic surgery has already been proven in cadaveric studies, it is our hypothesis that this newly designed robotically assisted system will achieve a high level of accuracy for bone resection. Therefore, we aimed to analyze in a cadaveric study the accuracy to achieve targeted angles and resection thickness. Methods: For this study, 15 frozen cadaveric specimens (30 knees) were used. In this study, Zimmer Biomet (Warsaw, IN) knees, navigation system, and robot (ROSA Knee System; Zimmer Biomet) were used. Eight trained, board-certified orthopedic surgeons performed robotically assisted total knee arthroplasty implantation using the same robotic protocol with 3 different implant designs. The target angles obtained from the intraoperative planning were then compared to the angles of the bone cuts performed using the robotic system and measured with the computer-assisted system considered to be the gold standard. For each bone cut the resection thickness was measured 3 times by 2 different observers and compared to the values for the planned resections. Results: All angle mean differences were below 1 degrees and standard deviations below 1 degrees. For all 6 angles, the mean differences between the target angle and the measured values were not significantly different from 0 except for the femoral flexion angle which had a mean difference of 0.95 degrees. The mean hip-knee-ankle axis difference was -0.03 degrees +/- 0.87 degrees. All resection mean differences were below 0.7 mm and standard deviations below 1.1mm. Conclusion: Despite the fact that this study was funded by Zimmer Biomet and only used Zimmer Biomet implants, robot, and navigation tools, the results of our in vitro study demonstrated that surgeons using this new surgical robot in total knee arthroplasty can perform highly accurate bone cuts to achieve the planned angles and resection thickness as measured using conventional navigation. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:2799 / 2803
页数:5
相关论文
共 16 条
[1]   Coronal alignment in total knee replacement HISTORICAL REVIEW, CONTEMPORARY ANALYSIS, AND FUTURE DIRECTION [J].
Abdel, M. P. ;
Oussedik, S. ;
Parratte, S. ;
Lustig, S. ;
Haddad, F. S. .
BONE & JOINT JOURNAL, 2014, 96B (07) :857-862
[2]   Measured Resection Versus Gap Balancing for Total Knee Arthroplasty [J].
Abdel, Matthew P. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (07) :2016-2022
[3]   Robotics in Total Knee Arthroplasty [J].
Bautista, Maria ;
Manrique, Jorge ;
Hozack, William J. .
JOURNAL OF KNEE SURGERY, 2019, 32 (07) :600-606
[4]   The accuracy of bone resections made during computer navigated total knee replacement. Do we resect what the computer plans we resect? [J].
Biant, Leela C. ;
Yeoh, Kwan ;
Walker, Peter M. ;
Bruce, Warwick J. M. ;
Walsh, William R. .
KNEE, 2008, 15 (03) :238-241
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Accuracy assessment of a novel image-free handheld robot for Total Knee Arthroplasty in a cadaveric study [J].
Casper, Michael ;
Mitra, Riddhit ;
Khare, Rahul ;
Jaramaz, Branislav ;
Hamlin, Brian ;
McGinley, Brian ;
Mayman, David ;
Headrick, Jeff ;
Urish, Kenneth ;
Gittins, Mark ;
Incavo, Stephen ;
Neginhal, Vivek .
COMPUTER ASSISTED SURGERY, 2018, 23 (01) :14-20
[7]   Distal femoral torsion: Comparison of CT scan and intra operative navigation measurements during total knee arthroplasty A report of 70 cases [J].
Galaud, B. ;
Beauflis, P. ;
Michaut, M. ;
Abadie, P. ;
Fallet, L. ;
Boisrenoult, P. .
REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2008, 94 (06) :573-579
[8]   Patient Dissatisfaction After Primary Total Joint Arthroplasty: The Patient Perspective [J].
Halawi, Mohamad J. ;
Jongbloed, Walter ;
Baron, Samuel ;
Savoy, Lawrence ;
Williams, Vincent J. ;
Cote, Mark P. .
JOURNAL OF ARTHROPLASTY, 2019, 34 (06) :1093-1096
[9]   Robotic-Arm Assisted Total Knee Arthroplasty Demonstrated Greater Accuracy and Precision to Plan Compared with Manual Techniques [J].
Hampp, Emily L. ;
Chughtai, Morad ;
Scholl, Laura Y. ;
Sodhi, Nipun ;
Bhowmik-Stoker, Manoshi ;
Jacofsky, David J. ;
Mont, Michael A. .
JOURNAL OF KNEE SURGERY, 2019, 32 (03) :239-250
[10]   Meta-Analysis of Navigation vs Conventional Total Knee Arthroplasty [J].
Hetaimish, Bandar M. ;
Khan, M. Moin ;
Simunovic, Nicole ;
Al-Harhi, Hatem H. ;
Bhandari, Mohit ;
Zalzal, Paul K. .
JOURNAL OF ARTHROPLASTY, 2012, 27 (06) :1177-1182