Surgical effect and long-term clinical outcomes of robotic mitral valve replacement: 10-year follow-up study

被引:5
作者
Zhao, Haizhi [1 ,2 ]
Gao, Changqing [1 ,3 ]
Yang, Ming [1 ]
Wang, Yao [1 ]
Kang, Wenbin [1 ]
Wang, Rong [1 ]
Zhang, Huajun [1 ,3 ]
机构
[1] Peoples Liberat Army Gen Hosp, Dept Cardiovasc Surg, 28 Fuxing Rd, Beijing 100853, Peoples R China
[2] Univ Cologne, Heart Ctr, Dept Cardiothorac Surg, Cologne, Germany
[3] Peoples Liberat Army Gen Hosp, Inst Cardiac Surg, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Minimally invasive surgical procedures; Robotics; Surgery; SURGERY; REPAIR; EXPERIENCE;
D O I
10.23736/S0021-9509.20.11508-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: To assess the safety and effectiveness, clinical experience with totally robotic mitral valve replacement (TE-MVR) for treating valvular heart disease was summarized and analyzed, and patients' recovery conditions were followed-up. METHODS: The clinical data of 47 patients who received TE-MVR in our hospital between October 2008 and December 2015 were retrospectively analyzed. Among the patients, there are 26 men and 21 women. The mean age was 47.53 +/- 10.80 years. We followed up the transesophageal echocardiography (TTE) data of post-discharge patients and analyzed the operation results to determine the surgical effects of TE-MVR. The surgeries were mainly performed with the da Vinci Si robotic surgical system. RESULTS: Thirty-five mechanical valves and twelve bioprosthetic valves were implanted. The cardiopulmonary bypass and aortic cross-clamping times were 122.02 +/- 25.45 min and 85.68 +/- 20.70 min, respectively. There was no operative mortality. The perioperative complication could only be found in one case, which was pleural effusion. All the TTE results were satisfying before discharge. No paravalvular leakage or prosthetic valve dysfunction was detected. All 47 patients were discharged successfully. During the long-term follow-up (28-110 months), 42 patients were followed-up (89.4%). Most of their heart function was NYHA class I and II. The postoperative TTE showed that the left atrial diameter and left ventricle diameter were decreased (P<0.01). CONCLUSIONS: TE-MVR is reliable and effective, and the postoperative follow-up results revealed good heart function. Patients will obtain benefits from TE-MVR, such as small trauma and rapid recovery. Thus, it is a good minimally-invasive surgery of choice.
引用
收藏
页码:162 / 168
页数:7
相关论文
共 28 条
  • [11] Kuo CC, 2018, EUR J CARDIO-THORAC, V54, P853, DOI 10.1093/ejcts/ezy134
  • [12] Surgical Experience of Primary Cardiac Tumor: Single-Institution 23-Year Report
    Li, Shuanglei
    Gao, Changqing
    [J]. MEDICAL SCIENCE MONITOR, 2017, 23 : 2111 - 2117
  • [13] Robotic mitral valve repair: 7-year surgical experience and mid-term follow-up results
    Liu, Guopeng
    Zhang, Huajun
    Yang, Ming
    Wang, Rong
    Xiao, Cangsong
    Wang, Gang
    Wang, Yao
    Gao, Changqing
    [J]. JOURNAL OF CARDIOVASCULAR SURGERY, 2019, 60 (03) : 406 - 412
  • [14] Comparison of automated fastener device Cor-Knot versus manually-tied knot in minimally-invasive isolated aortic valve replacement surgery
    Morgant, Marie-Catherine
    Malapert, Ghislain
    Petrosyan, Andranik
    Pujos, Charline
    Jazayeri, Saed
    Bouchot, Olivier
    [J]. JOURNAL OF CARDIOVASCULAR SURGERY, 2020, 61 (01) : 123 - 128
  • [15] The Expanding Role of Endoscopic Robotics in Mitral Valve Surgery: 1,257 Consecutive Procedures
    Murphy, Douglas A.
    Moss, Emmanuel
    Binongo, Jose
    Miller, Jeffrey S.
    Macheers, Steven K.
    Sarin, Eric L.
    Herzog, Alexander M.
    Thourani, Vinod H.
    Guyton, Robert A.
    Halkos, Michael E.
    [J]. ANNALS OF THORACIC SURGERY, 2015, 100 (05) : 1675 - 1682
  • [16] Robotic mitral valve surgery: A United States multicenter trial
    Nifong, LW
    Chitwood, WR
    Pappas, PS
    Smith, CR
    Argenziano, M
    Starnes, VA
    Shah, PM
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 129 (06) : 1395 - 1404
  • [17] Systematic review of robotic minimally invasive mitral valve surgery
    Seco, Michael
    Cao, Christopher
    Modi, Paul
    Bannon, Paul G.
    Wilson, Michael K.
    Vallely, Michael P.
    Phan, Kevin
    Misfeld, Martin
    Mohr, Friedrich
    Yan, Tristan D.
    [J]. ANNALS OF CARDIOTHORACIC SURGERY, 2013, 2 (06) : 704 - 716
  • [18] Senay S, 2014, MULTIMED MAN CARDIOT, V2014, P2014
  • [19] Robotic mitral valve replacement for rheumatic mitral disease
    Senay, Sahin
    Gullu, Ahmet Umit
    Alhan, Cem
    [J]. ANNALS OF CARDIOTHORACIC SURGERY, 2017, 6 (01) : 64 - 66
  • [20] Senay S, 2014, INNOVATIONS, V9, P292, DOI 10.1097/IMI.0000000000000078