Posterior Cruciate Ligament Graft Fixation Angles, Part 1 Biomechanical Evaluation for Anatomic Single-Bundle Reconstruction

被引:47
作者
Kennedy, Nicholas I. [1 ]
LaPrade, Robert F. [1 ]
Goldsmith, Mary T. [1 ]
Faucett, Scott C. [1 ]
Rasmussen, Matthew T. [1 ]
Coatney, Garrett A. [1 ]
Engebretsen, Lars [1 ]
Wijdicks, Coen A. [1 ]
机构
[1] Steadman Philippon Res Inst, Dept Biomed Engn, Vail, CO 81657 USA
关键词
posterior cruciate ligament (PCL); single-bundle PCL reconstruction; graft fixation angles; knee kinematics; graft forces; anterolateral bundle (ALB); IN-VITRO; POSTEROMEDIAL BUNDLES; KINEMATIC ANALYSIS; TENDON GRAFT; KNEE; TUNNEL; OUTCOMES; FLEXION; INJURY; JOINT;
D O I
10.1177/0363546514541225
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Currently, no consensus exists for the optimal graft fixation angle for anatomic single-bundle (SB) posterior cruciate ligament reconstructions (PCLRs). Additionally, direct graft forces have not been measured. Alternative graft fixation angles and the resultant graft forces should be investigated to optimize the stability of SB PCLRs without overconstraining the knee. Hypothesis: Graft fixation angles of 75 degrees, 90 degrees, and 105 degrees for SB PCLR were hypothesized to improve knee stability compared with the sectioned posterior cruciate ligament state with no evidence of knee overconstraint. Study Design: Controlled laboratory study. Methods: Nine fresh-frozen human cadaveric knees were biomechanically evaluated for the intact, sectioned, and SB PCLR states with the anterolateral bundle graft fixed at 75 degrees, 90 degrees, and 105 degrees. A 6 degrees of freedom robotic system assessed knee laxity with a 134-N posterior load applied at 0 degrees to 120 degrees and 5-N<bold>m external</bold>, 5-N<bold>m internal</bold>, and 10-N<bold>m valgus rotation torques applied at </bold>60 degrees to 120 degrees. By securing the graft to an external load cell, graft forces were measured throughout kinematic testing. Results: No significant kinematic differences were found among the 3 fixation angles. Each fixation angle resulted in significantly less posterior translation than in the sectioned state at all flexion angles (P < .05), with 4.1 mm of average residual laxity during an applied posterior loading. For all graft fixation angles, internal rotation was significantly increased between 60 degrees and 120 degrees of flexion, and external rotation was significantly increased at 90 degrees, 105 degrees, and 120 degrees of flexion compared with the intact state. Graft forces were not significantly different among the 3 fixation angles and remained below reported loads observed during activities of daily living. Conclusion: All tested SB PCLR graft fixation angles restored knee laxity to similar levels; however, persistent laxity resulted in significant increases in knee laxity compared with the intact state during posterior tibial loading at all flexion angles, internal rotation at flexion angles 60 degrees, and external rotation at 75 degrees of flexion. Clinical Relevance: The results of this study suggest that SB PCL graft fixation angles of 75 degrees, 90 degrees, and 105 degrees were comparable in restoring knee kinematics and exposed the graft to similar time-zero loads. However, SB PCLRs did not fully reduce knee laxity to the intact state.
引用
收藏
页码:2338 / 2345
页数:8
相关论文
共 40 条
[11]   Biomechanical Comparison of Anatomic Single- and Double-Bundle Anterior Cruciate Ligament Reconstructions An In Vitro Study [J].
Goldsmith, Mary T. ;
Jansson, Kyle S. ;
Smith, Sean D. ;
Engebretsen, Lars ;
LaPrade, Robert F. ;
Wijdicks, Coen A. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2013, 41 (07) :1595-1604
[12]   A JOINT COORDINATE SYSTEM FOR THE CLINICAL DESCRIPTION OF 3-DIMENSIONAL MOTIONS - APPLICATION TO THE KNEE [J].
GROOD, ES ;
SUNTAY, WJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (02) :136-144
[13]   THE HUMAN POSTERIOR CRUCIATE LIGAMENT COMPLEX - AN INTERDISCIPLINARY STUDY - LIGAMENT MORPHOLOGY AND BIOMECHANICAL EVALUATION [J].
HARNER, CD ;
XEROGEANES, JW ;
LIVESAY, GA ;
CARLIN, GJ ;
SMITH, BA ;
KUSAYAMA, T ;
KASHIWAGUCHI, S ;
WOO, SLY .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1995, 23 (06) :736-745
[14]   Biomechanical analysis of a double-bundle posterior cruciate ligament reconstruction [J].
Harner, CD ;
Janaushek, MA ;
Kanamori, A ;
Yagi, M ;
Vogrin, TM ;
Woo, SLY .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (02) :144-151
[15]   The effect of knee flexion angle and application of an anterior tibial load at the time of graft fixation on the biomechanics of a posterior cruciate ligament-reconstructed knee [J].
Harner, CD ;
Janaushek, MA ;
Ma, CB ;
Kanamori, A ;
Vogrin, TM ;
Woo, SLY .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (04) :460-465
[16]   Arthroscopic posterior cruciate ligament reconstruction: one- vs. two-tunnel technique [J].
Houe, T ;
Jorgensen, U .
SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2004, 14 (02) :107-111
[17]   POSTERIOR CRUCIATE LIGAMENT [J].
KENNEDY, JC ;
GRAINGER, RW .
JOURNAL OF TRAUMA, 1967, 7 (03) :367-+
[18]  
Kennedy NI, AM J SPORTS IN PRESS
[19]   Kinematic Analysis of the Posterior Cruciate Ligament, Part 1 The Individual and Collective Function of the Anterolateral and Posteromedial Bundles [J].
Kennedy, Nicholas I. ;
Wijdicks, Coen A. ;
Goldsmith, Mary T. ;
Michalski, Max P. ;
Devitt, Brian M. ;
Aroen, Asbjorn ;
Engebretsen, Lars ;
LaPrade, Robert F. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2013, 41 (12) :2828-2838
[20]   Clinical Results of Arthroscopic Single-Bundle Transtibial Posterior Cruciate Ligament Reconstruction A Systematic Review [J].
Kim, Young-Mo ;
Lee, Cassandra A. ;
Matava, Matthew J. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2011, 39 (02) :425-434