Reliability of the 6-minute walking test smartphone application

被引:36
作者
Stienen, Martin N. [1 ,2 ,3 ]
Gautschi, Oliver P. [4 ]
Staartjes, Victor E. [1 ,2 ]
Maldaner, Nicolai [5 ]
Sosnova, Marketa [5 ]
Ho, Allen L. [3 ]
Veeravagu, Anand [3 ]
Desai, Atman [3 ]
Zygourakis, Corinna C. [3 ]
Park, Jon [3 ]
Regli, Luca [1 ,2 ]
Ratliff, John K. [3 ]
机构
[1] Univ Hosp Zurich, Dept Neurosurg, Zurich, Switzerland
[2] Univ Zurich, Clin Neurosci Ctr, Zurich, Switzerland
[3] Stanford Univ Hosp & Clin, Dept Neurosurg, Stanford, CA USA
[4] Hirslanden Klin St Anna, Neurol & Spinal Surg Ctr, Luzern, Switzerland
[5] Kantonsspital St Gallen, Dept Neurosurg, St Gallen, Switzerland
关键词
6-minute walking test; degenerative disc disease; global positioning system; lumbar spinal stenosis; objective functional impairment; smartphone app; OBJECTIVE FUNCTIONAL IMPAIRMENT; REPORTED OUTCOME MEASURES; GO TEST; SPINAL STENOSIS; LUMBAR; SURGERY;
D O I
10.3171/2019.6.SPINE19559
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE Objective functional measures such as the 6-minute walking test (6WT) are increasingly applied to evaluate patients with degenerative diseases of the lumbar spine before and after (surgical) treatment. However, the traditional 6WT is cumbersome to apply, as it requires specialized in-hospital infrastructure and personnel. The authors set out to compare 6-minute walking distance (6WD) measurements obtained with a newly developed smartphone application (app) and those obtained with the gold-standard distance wheel (DW). METHODS The authors developed a free iOS- and Android-based smartphone app that allows patients to measure the 6WD in their home environment using global positioning system (GPS) coordinates. In a laboratory setting, the authors obtained 6WD measurements over a range of smartphone models, testing environments, and walking patterns and speeds. The main outcome was the relative measurement error (rME; in percent of 6WD), with vertical bar rME vertical bar< 7.5% defined as reliable. The intraclass correlation coefficient (ICC) for agreement between app- and DW-based 6WD was calculated. RESULTS Measurements (n = 406) were reliable with all smartphone types in neighborhood, nature, and city environments (without high buildings), as well as with unspecified, straight, continuous, and stop-and-go walking patterns (ICC = 0.97, 95% CI 0.97-0.98, p < 0.001). Measurements were unreliable indoors, in city areas with high buildings, and for predominantly rectangular walking courses. Walking speed had an influence on the ME, with worse accuracy (2% higher rME) for every kilometer per hour slower walking pace (95% CI 1.4%-2.5%, p < 0.001). Mathematical adjustment of the app-based 6WD for velocity-dependent error mitigated the rME (p < 0.011), attenuated velocity dependence (p = 0.362), and had a positive effect on accuracy (ICC = 0.98, 95% CI 0.98-0.99, p < 0.001). CONCLUSIONS The new, free, spine-specific 6WT smartphone app measures the 6WD conveniently by using GPS coordinates, empowering patients to independently determine their functional status before and after (surgical) treatment. Measurements of 6WD obtained for the target population under the recommended circumstances are highly reliable.
引用
收藏
页码:786 / 793
页数:8
相关论文
共 27 条
[1]   Outcomes and their predictors in lumbar spinal stenosis: a 12-year follow-up [J].
Adamova, B. ;
Vohanka, S. ;
Dusek, L. ;
Jarkovsky, J. ;
Chaloupka, R. ;
Bednarik, J. .
EUROPEAN SPINE JOURNAL, 2015, 24 (02) :369-380
[2]   Results of Database Studies in Spine Surgery Can Be Influenced by Missing Data [J].
Basques, Bryce A. ;
McLynn, Ryan P. ;
Fice, Michael P. ;
Samuel, Andre M. ;
Lukasiewicz, Adam M. ;
Bohl, Daniel D. ;
Ahn, Junyoung ;
Singh, Kern ;
Grauer, Jonathan N. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2017, 475 (12) :2893-2904
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Big data vs accurate data in health research: Large-scale physical activity monitoring, smartphones, wearable devices and risk of unconscious bias [J].
Brodie, M. A. ;
Pliner, E. M. ;
Ho, A. ;
Li, Kalina ;
Chen, Z. ;
Gandevi, S. C. ;
Lord, S. R. .
MEDICAL HYPOTHESES, 2018, 119 :32-36
[5]   Walking assessment in people with lumbar spinal stenosis: capacity, performance, and self-report measures [J].
Conway, Justin ;
Tomkins, Christy C. ;
Haig, Andrew J. .
SPINE JOURNAL, 2011, 11 (09) :816-823
[6]   Objective Assessment of the Cardiorespiratory Function of Adolescents With Idiopathic Scoliosis Through the Six-Minute Walk Test [J].
dos Santos Alves, Vera Lucia ;
Avanzi, Osmar .
SPINE, 2009, 34 (25) :E926-E929
[7]   Comparison of global positioning and computer-based tracking systems for measuring player movement distance during Australian Football [J].
Edgecomb, S. J. ;
Norton, K. I. .
JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2006, 9 (1-2) :25-32
[8]  
FOREMAN SM, 1985, J MANIP PHYSIOL THER, V8, P81
[9]   A Randomized, Controlled Trial of Fusion Surgery for Lumbar Spinal Stenosis [J].
Forsth, Peter ;
Olafsson, Gylfi ;
Carlsson, Thomas ;
Frost, Anders ;
Borgstrom, Fredrik ;
Fritzell, Peter ;
Ohagen, Patrik ;
Michaelsson, Karl ;
Sanden, Bengt .
NEW ENGLAND JOURNAL OF MEDICINE, 2016, 374 (15) :1413-1423
[10]   Assessment of the Minimum Clinically Important Difference in the Timed Up and Go Test After Surgery for Lumbar Degenerative Disc Disease [J].
Gautschi, Oliver P. ;
Stienen, Martin N. ;
Corniola, Marco V. ;
Joswig, Holger ;
Schaller, Karl ;
Hildebrandt, Gerhard ;
Smoll, Nicolas R. .
NEUROSURGERY, 2017, 80 (03) :380-384