Field-assisted paper spray mass spectrometry for therapeutic drug monitoring: 1. the case of imatinib in plasma

被引:3
作者
D'Aronco, S. [1 ]
Dall'Armi, M. [2 ]
Crotti, S. [1 ]
Calandra, E. [1 ]
Traldi, P. [1 ]
Di Marco, V. [2 ]
Buonadonna, A. [3 ]
Corona, G. [3 ]
Giodini, L. [3 ]
Marangon, E. [3 ]
Posocco, B. [3 ]
Toffoli, G. [3 ]
Agostini, M. [1 ,4 ]
机构
[1] Inst Paediat Res Citta Speranza, Nanoinspired Biomed Lab, Corso Stati Uniti 4, I-35127 Padua, Italy
[2] Univ Padua, Dept Chem Sci, Via Marzolo 1, I-35131 Padua, Italy
[3] IRCCS, Natl Canc Inst, Ctr Riferimento Oncol, Expt & Clin Pharmacol Unit, Via Franco Gallini 2, I-33081 Aviano, PN, Italy
[4] Univ Padua, Surg Clin, Dept Surg Oncol & Gastroenterol Sci, Via Nicolo Giustiniani 2, I-35128 Padua, Italy
来源
JOURNAL OF MASS SPECTROMETRY | 2017年 / 52卷 / 05期
关键词
imatinib; paper spray; comparison PS and LC-MS/MS; therapeutic drug monitoring; imatinib in plasma; PHARMACOKINETICS; QUANTIFICATION; METABOLITES; RESPONSES; BLOOD; ASSAY;
D O I
10.1002/jms.3927
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The field-assisted paper spray (FAPS) - mass spectrometric method has been employed to quantify the imatinib (IMT) plasma levels in treated patients. The quantitative measurements have been performed on the collisionally generated fragment at m/z 394 of the protonated molecules of IMT and deuterated IMT (d(3)-IMT), used as internal standard. The FAPS-tandem mass spectrometry (MS/MS) method exhibits some limitations, because of the high number of operative parameters that need to be carefully controlled. For this aim, papers of different geometry, thickness, and porosity were tested. To obtain a more focalized and intense electrical field, a stainless steel needle was mounted axially and placed at 4 kV voltage. The variability observed in the measurements was ascribed either to the inter-individual variability (e.g. the concomitant presence of other compounds such as proteins, lipids, drugs and/or salts in the plasma of different patients) or to the uncontrollable variables in the instrumental setup (e.g. sample deposition, changes in paper spray conditions). Furthermore, the manual sample deposition and solvent dripping strongly affects the measure reproducibility. Despite this, it is interesting to observe that, once applied in blind on 24 real plasma samples, FAPS-MS/MS led to results analogous to those obtained by the well-consolidated liquid chromatography-MS/MS, even if the mean coefficient of variation % (CV%) values of 20.4% and 2.6% were observed for the two methods, respectively. In conclusion, despite CV values are relatively high, it is worth noting that the FAPS-MS/MS method is much more straightforward, rapid and economical than the liquid chromatography-MS/MS one, and it appears therefore very promising for applicationswhere a high precision is not always a required task, as e.g. in some cases of therapeutic drug monitoring. Copyright (C) 2017 John Wiley & Sons, Ltd.
引用
收藏
页码:283 / 289
页数:7
相关论文
共 26 条
  • [1] Fluorescence studies of anti-cancer drugs - Analytical and biomedical applications
    Aaron, Jean-Jacques
    Trajkovska, Snezana
    [J]. CURRENT DRUG TARGETS, 2006, 7 (09) : 1067 - 1081
  • [2] [Anonymous], INT C HARM
  • [3] [Anonymous], PRACTICAL ASPECTS IO
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] Field-assisted paper spray mass spectrometry for the quantitative evaluation of imatinib levels in plasma
    D'Aronco, Sara
    Calandra, Eleonora
    Crotti, Sara
    Toffoli, Giuseppe
    Marangon, Elena
    Posocco, Bianca
    Traldi, Pietro
    Agostini, Marco
    [J]. EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2016, 22 (05) : 217 - 228
  • [6] Darwish Ibrahim A, 2006, Int J Biomed Sci, V2, P217
  • [7] Validation of a high-performance liquid chromatographic assay method for quantification of total vincristine sulfate in human plasma following administration of vincristine sulfate liposome injection
    Embree, L
    Gelmon, KA
    Tolcher, AW
    Hudon, NJ
    Heggie, JR
    Dedhar, C
    Webb, MS
    Bally, MB
    Mayer, LD
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 16 (04) : 675 - 687
  • [8] Spray mechanism in paper spray ionization
    Espy, Ryan D.
    Muliadi, Ariel R.
    Ouyang, Zheng
    Cooks, R. Graham
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2012, 325 : 167 - 171
  • [9] Rapid analysis of whole blood by paper spray mass spectrometry for point-of-care therapeutic drug monitoring
    Espy, Ryan D.
    Manicke, Nicholas E.
    Ouyang, Zheng
    Cooks, R. Graham
    [J]. ANALYST, 2012, 137 (10) : 2344 - 2349
  • [10] A COMPARISON BETWEEN ION TRAP AND TRIPLE QUADRUPOLE COLLISION-RESULTS
    EVANS, C
    TRALDI, P
    MELE, A
    SOTTANI, C
    [J]. ORGANIC MASS SPECTROMETRY, 1991, 26 (04): : 347 - 349