The Less Invasive Stabilization System in the treatment of complex fractures of the tibial plateau: Short-term results

被引:79
作者
Stannard, JP [1 ]
Wilson, TC [1 ]
Volgas, DA [1 ]
Alonso, JE [1 ]
机构
[1] Univ Alabama Birmingham, Div Orthopaed Surg, Birmingham, AL USA
关键词
tibial plateau fractures; less invasive stabilization system (LISS);
D O I
10.1097/00005131-200409000-00012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: To report on the use of a new plating system in the treatment of high-energy tibial plateau fractures using minimally invasive stabilization techniques. Design: Prospective, consecutive patient series. Setting: University Level I trauma center. Patients: Thirty-seven patients with 39 fractures of the tibial plateau were treated using specialty plates. All fractures were OTA class 41 C. Ten of the fractures were open, including eight Gustilo and Anderson Type IIIA and two Type IIIB. Thirty-three patients with 34 fractures had follow-up of at least 12 months. Intervention: Internal fixation with the Less Invasive Stabilization System (LISS, Synthes USA, Paoli, PA) using minimally invasive techniques. Main Outcome Management: To determine clinical outcome, time to union, fracture alignment, articular step-off, incidence of complications, Short Form-36 outcome scores, and Lysholm knee scores in patients with associated ligament injuries. Results: All 34 of the fractures healed without additional surgical intervention or bone grafting. The mean follow-up in our series was 21 months, with a range of 12 to 38 months. Twenty-nine patients with 30 fractures had follow-up of greater than 1 year. The average time to radiographic callus was 6.1 weeks, and the average time to complete union was 15.6 weeks. The articular step-off average was 0.8 mm, with a range of 0 to 5 mm. The postoperative alignment demonstrated 1 patient with a malalignment of 5degrees procurvatum and 1 patient with 4degrees of valgus. There were two superficial wound infections and no cases of deep infection or osteomyelitis. Conclusions: The use of LISS plates appears to stabilize complex fractures of the tibial plateau with a low incidence of complications. The LISS system functioned well in maintaining alignment and obtaining union in these high-energy fractures.
引用
收藏
页码:552 / 558
页数:7
相关论文
共 36 条
  • [1] BLOKKER CP, 1984, CLIN ORTHOP RELAT R, V182, P193
  • [2] BURRI C, 1979, CLIN ORTHOP RELAT R, V138, P84
  • [3] Collinge C, 2000, CLIN ORTHOP RELAT R, P69
  • [4] Collins A, 2000, SWINE HEALTH PROD, V8, P211
  • [5] Treatment of high-energy tibial plateau fractures by the Ilizarov circular fixator
    Dendrinos, GK
    Kontos, S
    Katsenis, D
    Dalas, A
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (05): : 710 - 717
  • [6] DUWELIUS PJ, 1997, CLIN ORTHOP RELAT R, V339, P47
  • [7] Farouk O, 1997, INJURY, V28, pSA7
  • [8] Minimally invasive plate osteosynthesis: Does percutaneous plating disrupt femoral blood supply less than the traditional technique?
    Farouk, O
    Krettek, C
    Miclau, T
    Schandelmaier, P
    Guy, P
    Tscherne, H
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (06) : 401 - 406
  • [9] The development of the distal femur Less Invasive Stabilization System (LISS)
    Frigg, R
    Appenzeller, A
    Christensen, R
    Frenk, A
    Gilbert, S
    Schavan, R
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2001, 32 : 24 - 31
  • [10] Gaudinez RF, 1996, CLIN ORTHOP RELAT R, P203