Static blood-flow control during cardiopulmonary bypass is a compromise of oxygen delivery

被引:9
作者
Svenmarker, Staffan [1 ]
Haggmark, Soren [1 ]
Hultin, Magnus [2 ]
Holmgren, Anders [1 ]
机构
[1] Umea Univ Hosp, Ctr Heart, Dept Surg & Perioperat Sci, SE-90185 Umea, Sweden
[2] Umea Univ Hosp, Dept Surg & Perioperat Sci, SE-90185 Umea, Sweden
关键词
Cardiopulmonary bypass; Metabolism; Oxygen consumption; Vascular resistance; Monitoring; SATURATION; HEMODILUTION; TEMPERATURE; ANEMIA;
D O I
10.1016/j.ejcts.2009.05.019
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Blood-flow control during cardiopulmonary bypass (CPB) is by tradition based on the patient's body surface area. Emergence of new techniques enables dynamic blood-flow control based on online measurement of venous oxygen saturation and oxygen consumption. Present investigation aimed to compare static versus dynamic blood-flow control with respect to use of oxygen and effects upon organ function. Methods: In this study, 100 coronary-artery-bypass surgical patients were prospectively randomised to static or dynamic hypothermic blood-flow control during CPB. In the static group, pump flow was set to 2.4 ( litres per minute) times the patient's body surface area ( m 2) throughout the procedure. Pump flow in the dynamic group was varied according to the reading of the venous oxygen saturation and maintained at >75%. CPB-specific information was collected online. Blood samples were collected for analysis of haemoglobin, lactate, amylase, creatinine and C-reactive protein: pre-CPB, at weaning from CPB and on day 1 postoperatively. Results: Randomisation formed two uniform groups. Choice of static or dynamic blood-flow control during CPB had no significant effects on organ function as judged by lactate, amylase or creatinine levels. On increasing oxygen demand, oxygen balance was maintained by increasing venous oxygen extraction rates in the static flow mode and by increasing the pump flow rate in the dynamic group. Conclusions: Independent of the blood-flow control mode, oxygen balance remained preserved. However, the dynamic mode provided higher oxygen delivery, which may increase margins of safety and protection of organ function. (C) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:218 / 222
页数:5
相关论文
共 26 条
[1]   Is body surface area still the best way to determine pump flow rate during cardiopulmonary bypass? [J].
Alston, RP ;
Anderson, A ;
Sanger, K .
PERFUSION-UK, 2006, 21 (03) :139-147
[2]  
ALSTON RP, 1989, J THORAC CARDIOV SUR, V98, P757
[3]  
Asopa Sanjay, 2007, Acute Card Care, V9, P63, DOI 10.1080/17482940601064767
[4]  
Baker Robert A, 2006, J Extra Corpor Technol, V38, P220
[5]   Significance of venous oximetry in the critically ill [J].
Bauer, P. ;
Reinhart, K. ;
Bauer, M. .
MEDICINA INTENSIVA, 2008, 32 (03) :134-142
[6]   Theoretical model of blood flow autoregulation: roles of myogenic, shear-dependent, and metabolic responses [J].
Carlson, Brian E. ;
Arciero, Julia C. ;
Secomb, Timothy W. .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2008, 295 (04) :H1572-H1579
[7]  
Cook DJ, 1998, CIRCULATION, V98, pII170
[8]  
COOK DJ, 1998, CIRCULATION S, V98, P1
[9]   Lowest core body temperature and adverse outcomes associated with coronary artery bypass surgery [J].
DeFoe, GR ;
Krumholz, CF ;
DioDato, CP ;
Ross, CS ;
Olmstead, EM ;
Groom, RC ;
Pieroni, JW ;
Forest, RJ ;
O'Connor, BR ;
Bogosian, ME ;
Warren, CS ;
O'Connor, GT .
PERFUSION-UK, 2003, 18 (02) :127-133
[10]   A formula to estimate the approximate surface area if height and weight be known [J].
Du Bois, D ;
Du Bois, EF .
ARCHIVES OF INTERNAL MEDICINE, 1916, 17 (06) :863-871