Deep learning enables reduced gadolinium dose for contrast-enhanced brain MRI

被引:242
作者
Gong, Enhao [1 ,2 ]
Pauly, John M. [1 ]
Wintermark, Max [2 ]
Zaharchuk, Greg [2 ]
机构
[1] Stanford Univ, Dept Elect Engn, 1267 Lakeside Dr,Apt 2082, Sunnyvale, CA 94085 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
deep learning; contrast enhanced MRI; gadolinium deposition; low dose; image quality; machine learning; HIGH SIGNAL INTENSITY; DENTATE NUCLEUS; MULTIPLE-SCLEROSIS; DISEASE-ACTIVITY; GLOBUS-PALLIDUS; DEPOSITION; IMAGES; AGENTS; SENSITIVITY; LESIONS;
D O I
10.1002/jmri.25970
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThere are concerns over gadolinium deposition from gadolinium-based contrast agents (GBCA) administration. PurposeTo reduce gadolinium dose in contrast-enhanced brain MRI using a deep learning method. Study typeRetrospective, crossover. PopulationSixty patients receiving clinically indicated contrast-enhanced brain MRI. Sequence3D T-1-weighted inversion-recovery prepped fast-spoiled-gradient-echo (IR-FSPGR) imaging was acquired at both 1.5T and 3T. In 60 brain MRI exams, the IR-FSPGR sequence was obtained under three conditions: precontrast, postcontrast images with 10% low-dose (0.01mmol/kg) and 100% full-dose (0.1 mmol/kg) of gadobenate dimeglumine. We trained a deep learning model using the first 10 cases (with mixed indications) to approximate full-dose images from the precontrast and low-dose images. Synthesized full-dose images were created using the trained model in two test sets: 20 patients with mixed indications and 30 patients with glioma. AssessmentFor both test sets, low-dose, true full-dose, and the synthesized full-dose postcontrast image sets were compared quantitatively using peak-signal-to-noise-ratios (PSNR) and structural-similarity-index (SSIM). For the test set comprised of 20 patients with mixed indications, two neuroradiologists scored blindly and independently for the three postcontrast image sets, evaluating image quality, motion-artifact suppression, and contrast enhancement compared with precontrast images. Statistical AnalysisResults were assessed using paired t-tests and noninferiority tests. ResultsThe proposed deep learning method yielded significant (n=50, P<0.001) improvements over the low-dose images (>5 dB PSNR gains and >11.0% SSIM). Ratings on image quality (n=20, P=0.003) and contrast enhancement (n=20, P<0.001) were significantly increased. Compared to true full-dose images, the synthesized full-dose images have a slight but not significant reduction in image quality (n=20, P=0.083) and contrast enhancement (n=20, P=0.068). Slightly better (n=20, P=0.039) motion-artifact suppression was noted in the synthesized images. The noninferiority test rejects the inferiority of the synthesized to true full-dose images for image quality (95% CI: -14-9%), artifacts suppression (95% CI: -5-20%), and contrast enhancement (95% CI: -13-6%). Data ConclusionWith the proposed deep learning method, gadolinium dose can be reduced 10-fold while preserving contrast information and avoiding significant image quality degradation. Level of Evidence: 3 Technical Efficacy: Stage 5 J. MAGN. RESON. IMAGING 2018;48:330-340.
引用
收藏
页码:330 / 340
页数:11
相关论文
共 39 条
[1]  
[Anonymous], J MAGN RESON IMAGING
[2]  
[Anonymous], ARXIV170408841
[3]  
[Anonymous], J MAGN RESON IMAGING
[4]  
[Anonymous], 2016, IEEE C COMP VIS PATT
[5]   Convolutional Neural Network for Reconstruction of 7T-like Images from 3T MRI Using Appearance and Anatomical Features [J].
Bahrami, Khosro ;
Shi, Feng ;
Rekik, Islem ;
Shen, Dinggang .
DEEP LEARNING AND DATA LABELING FOR MEDICAL APPLICATIONS, 2016, 10008 :39-47
[6]   Signal Enhancement of the Dentate Nucleus at Unenhanced MR Imaging after Very High Cumulative Doses of the Macrocyclic Gadolinium-based Contrast Agent Gadobutrol: An Observational Study [J].
Bjornerud, Atle ;
Vatnehol, Svein Are Sirirud ;
Larsson, Christopher ;
Due-Tonnessen, Paulina ;
Hol, Per Kristian ;
Groote, Inge Rasmus .
RADIOLOGY, 2017, 285 (02) :434-444
[7]   The Role of Preload and Leakage Correction in Gadolinium-Based Cerebral Blood Volume Estimation Determined by Comparison with MION as a Criterion Standard [J].
Boxerman, J. L. ;
Prah, D. E. ;
Paulson, E. S. ;
Machan, J. T. ;
Bedekar, D. ;
Schmainda, K. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) :1081-1087
[8]   Gadolinium deposition in nephrogenic fibrosing dermopathy [J].
Boyd, Alan S. ;
Zic, John A. ;
Abraham, Jerrold L. .
JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2007, 56 (01) :27-30
[9]   CONTRAST-ENHANCED NMR IMAGING - ANIMAL STUDIES USING GADOLINIUM-DTPA COMPLEX [J].
BRASCH, RC ;
WEINMANN, HJ ;
WESBEY, GE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 142 (03) :625-630
[10]   MRI angiography is superior to helical CT for detection of HCC prior to liver transplantation:: An explant correlation [J].
Burrel, M ;
Llovet, JM ;
Ayuso, C ;
Iglesias, C ;
Sala, M ;
Miquel, R ;
Caralt, T ;
Ayuso, JR ;
Solé, M ;
Sanchez, M ;
Brú, C ;
Bruix, J .
HEPATOLOGY, 2003, 38 (04) :1034-1042