Accuracy of stroke volume variation compared with pleth variability index to predict fluid responsiveness in mechanically ventilated patients undergoing major surgery

被引:152
作者
Zimmermann, Markus [1 ]
Feibicke, Thomas [1 ]
Keyl, Cornelius [2 ]
Prasser, Christopher [1 ]
Moritz, Stefan [1 ]
Graf, Bernhard M. [1 ]
Wiesenack, Christoph [1 ]
机构
[1] Univ Hosp Regensburg, Dept Anaesthesiol, D-93052 Regensburg, Germany
[2] Heart Ctr Bad Krozingen, Dept Anaesthesiol, Bad Krozingen, Germany
关键词
fluid responsiveness; major abdominal surgery; pleth variability index; pulse oximeter plethysmography; stroke volume variation; CARDIAC-OUTPUT ASSESSMENT; PULSE PRESSURE VARIATION; WAVE-FORM AMPLITUDE; RESPIRATORY VARIATIONS; MONITOR; FLOTRAC(TM); PARAMETERS; ABILITY; SYSTEM;
D O I
10.1097/EJA.0b013e328335fbd1
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and objective Accurate assessment of a patient's volume status is an important goal for an anaesthetist. However, most variables assessing fluid responsiveness are either invasive or technically challenging. This study was designed to compare the accuracy of arterial pressure-based stroke volume variation (SVV) and variations in the pulse oximeter plethysmographic waveform amplitude as evaluated with the noninvasive calculated pleth variability index (PVI) with central venous pressure to predict the response of stroke volume index (SVI) to volume replacement in patients undergoing major surgery. Methods We studied 20 patients scheduled for elective major abdominal surgery. After induction of anaesthesia, all haemodynamic variables were recorded immediately before (T1) and subsequent to volume replacement (T2) by infusion of 6% hydroxy-ethyl starch (HES) 130/0.4 (7 ml kg(-1)) at a rate of 1ml kg(-1) min(-1). Results The volume-induced increase in SVI was at least 15% in 15 patients (responders) and less than 15% in five patients (nonresponders). Baseline SVV correlated significantly with changes in SVI (Delta SVI; r=0.80; P<0.001) as did baseline PVI (r=0.61; P<0.004), whereas baseline values of central venous pressure showed no correlation to DSVI. There was no significant difference between the area under the receiver operating characteristic curve for SVV (0.993) and PVI (0.973). The best threshold values to predict fluid responsiveness were more than 11% for SVV and more than 9.5% for PVI. Conclusion Although arterial pressure-derived SVV revealed the best correlation to volume-induced changes in SVI, the results of our study suggest that both variables, SVV and PVI, can serve as valid indicators of fluid responsiveness in mechanically ventilated patients undergoing major surgery. Eur J Anaesthesiol 2010;27:555-561
引用
收藏
页码:555 / 561
页数:7
相关论文
共 27 条
[1]   Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation [J].
Biais, M. ;
Nouette-Gaulain, K. ;
Cottenceau, V. ;
Revel, P. ;
Sztark, F. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (06) :761-768
[2]   Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients [J].
Boulain, T ;
Achard, JM ;
Teboul, JL ;
Richard, C ;
Perrotin, D ;
Ginies, G .
CHEST, 2002, 121 (04) :1245-1252
[3]   Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre [J].
Cannesson, M. ;
Desebbe, O. ;
Rosamel, P. ;
Delannoy, B. ;
Robin, J. ;
Bastien, O. ;
Lehot, J. -J. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (02) :200-206
[4]   Does the pleth variability index indicate the respiratory-induced variation in the plethysmogram and arterial pressure waveforms? [J].
Cannesson, Maxime ;
Delannoy, Bertrand ;
Morand, Antoine ;
Rosamel, Pascal ;
Attof, Yassin ;
Bastien, Olivier ;
Lehot, Jean-Jacques .
ANESTHESIA AND ANALGESIA, 2008, 106 (04) :1189-1194
[5]   The Ability of Stroke Volume Variations Obtained with Vigileo/FloTrac System to Monitor Fluid Responsiveness in Mechanically Ventilated Patients [J].
Cannesson, Maxime ;
Musard, Henri ;
Desebbe, Olivier ;
Boucau, Cecile ;
Simon, Remi ;
Henaine, Roland ;
Lehot, Jean-Jacques .
ANESTHESIA AND ANALGESIA, 2009, 108 (02) :513-517
[6]   Stroke volume variation obtained with FloTrac/Vigileo™ fails to predict fluid responsiveness in coronary artery bypass graft patients [J].
de Waal, E. E. C. ;
Rex, S. ;
Kruitwagen, C. L. J. J. ;
Kalkman, C. J. ;
Buhre, W. F. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 100 (05) :725-726
[7]   Cardiac output monitoring [J].
de Waal, Eric. E. C. ;
Wappler, Frank ;
Buhre, Wolfgang F. .
CURRENT OPINION IN ANESTHESIOLOGY, 2009, 22 (01) :71-77
[8]   Using ventilation-induced plethysmographic variations to optimize patient fluid status [J].
Desebbe, Olivier ;
Cannesson, Maxime .
CURRENT OPINION IN ANESTHESIOLOGY, 2008, 21 (06) :772-778
[9]   A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1983, 148 (03) :839-843
[10]   Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac™ and PiCCOplus™ system [J].
Hofer, Christoph K. ;
Senn, Alban ;
Weibel, Luc ;
Zollinger, Andreas .
CRITICAL CARE, 2008, 12 (03)