Development a new method for the determination of paromomycin in trace amounts by fast Fourier continuous cyclic voltammetry at an Au microelectrode in a flowing system

被引:32
作者
Ganjali, Mohammad Reza [1 ]
Norouzi, Parviz [1 ]
Daneshgar, Parandis [1 ]
Sepehri, Ali [1 ]
机构
[1] Univ Tehran, Dept Chem, Ctr Excellence Electrochem, Tehran, Iran
关键词
paromomycin; ultramicroelectrode; continuous cyclic voltammetry; flow injection analysis; fast Fourier transformation;
D O I
10.1016/j.snb.2006.11.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For the first time the technique of fast continuous cyclic voltammetry is used as a highly sensitive detection method for the monitoring of paromomycin in a flow-injection system. A special computer-based numerical calculation method (using fast Fourier transformation) is introduced here for the enhancement of the analyte signal and noise reduction. This research includes the observation of the effects of various parameters (rest potential, sweep rate and delay time) on the sensitivity of the detection system. Furthermore, a potential waveform, consisting of the potential steps for cleaning, accumulation and the step for the potential ramp of the analyte, was applied to an An disk microelectrode in a continuous way. Eventually, the method was found to be linear for the concentration range of 160-160,000 pg/mL (r = 0.999) with a limit of detection (LOD) and quantitation (LOQ) 49.25 and 160 pg/mL, respectively. The stripping time was less than 300 ms, while the detection limit was about 10,000 times lower than that of the most sensitive reported method. As a result, the system illustrates the requisite accuracy, sensitivity, precision and selectivity to assay paromomycin in capsules. (C) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1125 / 1132
页数:8
相关论文
共 42 条
  • [31] Fast Fourier continuous cyclic voltammetry at gold ultramicroelectrode in flowing solution for determination of ultra trace amounts of penicillin G
    Norouzi, Parviz
    Ganjali, Mohammad Reza
    Alizadeh, Taher
    Daneshgar, Parandis
    [J]. ELECTROANALYSIS, 2006, 18 (10) : 947 - 954
  • [32] Fast monitoring of nano-molar level of gentamycin by fast fourier transform continuous cyclic voltammetry in flowing solution
    Norouzi, Parviz
    Ganjali, Mohammad Reza
    Hajiaghababaei, Leila
    [J]. ANALYTICAL LETTERS, 2006, 39 (09) : 1941 - 1953
  • [33] A chemical assessment and HPLC assay validation of bulk paromomycin sulfate
    Olson, LL
    Pick, J
    Ellis, WY
    Lim, P
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (06) : 783 - 793
  • [34] Voltammetric multichannel measurements using silicon fabricated microelectrode arrays
    Paeschke, M
    Dietrich, F
    Uhlig, A
    Hintsche, R
    [J]. ELECTROANALYSIS, 1996, 8 (10) : 891 - 898
  • [35] FLUORESCENCE REACTION FOR AMINO ACIDS
    ROTH, M
    [J]. ANALYTICAL CHEMISTRY, 1971, 43 (07) : 880 - &
  • [36] SHABIR GA, VALIDATION HIGH PERF
  • [37] Fabrication and characterization of sputtered-carbon microelectrode arrays
    Sreenivas, G
    Ang, SS
    Fritsch, I
    Brown, WD
    Gerhardt, GA
    Woodward, DJ
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (11) : 1858 - 1864
  • [38] GAS-LIQUID CHROMATOGRAPHIC DETERMINATION OF AMINO-GLYCOSIDE ANTIBIOTICS - KANAMYCIN AND PAROMOMYCIN
    TSUJI, K
    ROBERTSON, JH
    [J]. ANALYTICAL CHEMISTRY, 1970, 42 (13) : 1661 - +
  • [39] *US PHARM CONV INC, 2005, US PHARM, V28, P2748
  • [40] Wang J., 1985, STRIPPING ANAL