Development a new method for the determination of paromomycin in trace amounts by fast Fourier continuous cyclic voltammetry at an Au microelectrode in a flowing system

被引:32
作者
Ganjali, Mohammad Reza [1 ]
Norouzi, Parviz [1 ]
Daneshgar, Parandis [1 ]
Sepehri, Ali [1 ]
机构
[1] Univ Tehran, Dept Chem, Ctr Excellence Electrochem, Tehran, Iran
关键词
paromomycin; ultramicroelectrode; continuous cyclic voltammetry; flow injection analysis; fast Fourier transformation;
D O I
10.1016/j.snb.2006.11.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For the first time the technique of fast continuous cyclic voltammetry is used as a highly sensitive detection method for the monitoring of paromomycin in a flow-injection system. A special computer-based numerical calculation method (using fast Fourier transformation) is introduced here for the enhancement of the analyte signal and noise reduction. This research includes the observation of the effects of various parameters (rest potential, sweep rate and delay time) on the sensitivity of the detection system. Furthermore, a potential waveform, consisting of the potential steps for cleaning, accumulation and the step for the potential ramp of the analyte, was applied to an An disk microelectrode in a continuous way. Eventually, the method was found to be linear for the concentration range of 160-160,000 pg/mL (r = 0.999) with a limit of detection (LOD) and quantitation (LOQ) 49.25 and 160 pg/mL, respectively. The stripping time was less than 300 ms, while the detection limit was about 10,000 times lower than that of the most sensitive reported method. As a result, the system illustrates the requisite accuracy, sensitivity, precision and selectivity to assay paromomycin in capsules. (C) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1125 / 1132
页数:8
相关论文
共 42 条
  • [1] ACKERMANS MT, 1992, J CHROMATOGR, V606, P229
  • [2] High performance liquid chromatography method for determination of methyl-5-benzoyl-2-benzimidazole carbamate (mebendazole) and its main degradation product in pharmaceutical dosage forms
    Al-Kurdi, Z
    Al-Jallad, T
    Badwan, A
    Jaber, AMY
    [J]. TALANTA, 1999, 50 (05) : 1089 - 1097
  • [3] [Anonymous], 1984, LAB TECHNIQUES ELECT
  • [4] BARANSKI AS, 1996, P ELECTROCHEM SOC, V9, P41
  • [5] Bockris J., 1980, COMPR TREAT
  • [6] MEDIATION OF OXIDATION REACTIONS AT NOBLE-METAL ANODES BY LOW-LEVELS OF INSITU GENERATED HYDROXY SPECIES
    BURKE, LD
    ODWYER, KJ
    [J]. ELECTROCHIMICA ACTA, 1989, 34 (12) : 1659 - 1664
  • [7] KINETIC AND OPTICAL RELAXATION STUDIES OF ADSORBED INTERMEDIATES IN SOME ELECTROCHEMICAL REACTIONS
    CONWAY, BE
    ANGERSTE.H
    HO, FC
    KLINGER, J
    MACDOUGA.B
    GOTTESFE.S
    [J]. FARADAY DISCUSSIONS, 1973, 56 : 210 - +
  • [8] MICROFABRICATED SENSOR ARRAYS SENSITIVE TO PH AND K+ FOR IONIC DISTRIBUTION MEASUREMENTS IN THE BEATING HEART
    COSOFRET, VV
    ERDOSY, M
    JOHNSON, TA
    BUCK, RP
    ASH, RB
    NEUMAN, MR
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (10) : 1647 - 1653
  • [9] Serial array of ISEs for use in a portable battery-powered flow injection analyzer
    Dimitrakopoulos, T
    Alexander, PW
    Hibbert, DB
    [J]. ELECTROANALYSIS, 1996, 8 (05) : 438 - 442
  • [10] Validation in pharmaceutical analysis. Part I: An integrated approach
    Ermer, J
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 24 (5-6) : 755 - 767