A Passive Adaptive Suspended Mass Pendulum to Compensate Detuning Due to Large Swing Angle

被引:5
作者
Huo, Linsheng [1 ]
Huang, Chen [1 ]
Zhang, Yuwan [1 ]
Li, Hongnan [1 ]
机构
[1] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116023, Peoples R China
基金
中国国家自然科学基金;
关键词
Passive adaptive suspended mass pendulum (PASMP); frequency detuning; vibration control; shaking table test; transmission tower; CONTROL PERFORMANCE; DAMPER; VIBRATION; LENGTH; IDENTIFICATION; DYNAMICS; BEHAVIOR; DESIGN; WIRE;
D O I
10.1142/S0219455421501236
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The suspended mass pendulum (SMP) conventionally used is a type of frequency sensitive vibration control device. It is vulnerable to detuning due to large amplitude oscillations, which can lead to a significant loss in vibration control performance. Although active or semi-active control systems can solve the problem of frequency detuning, the reliability and stability of the sensors and actuators in the control system are difficult to guarantee for large-scale civil structures. To overcome this issue, this study proposes a passive adaptive suspended mass pendulum (PASMP) that uses a curved support. First, the mathematical equations describing the curved support are derived to show that it can keep the frequency of the pendulum constant at large swing angles. Then the kinematic equations of a single-degree-of-freedom (SDOF) structure installed with the PASMP are established. A parametric analysis is conducted to verify how the parameters of the control system, including the excitation period, pendulum length and mass ratio, affect the dynamic responses of the main structure. Furthermore, to verify the effectiveness of the PASMP and the validity of the theoretical analysis, a two-story frame structure is chosen as the model structure in shaking table tests. Also, the proposed PASMP is applied to a transmission tower to numerically verify its effectiveness of vibration suppression under different seismic excitations. The numerical and experimental results demonstrate that the PASMP can more effectively suppress the vibration of structures than the conventionally used SMP.
引用
收藏
页数:36
相关论文
共 56 条
  • [21] [霍林生 Huo Linsheng], 2019, [防灾减灾工程学报, Journal of Disaster Prevention and Mitigation Engineering], V39, P898
  • [22] Nonlinear responses of spherical pendulum vibration absorbers in towerlike 2DOF structures
    Ikeda, Takashi
    Harata, Yuji
    Takeeda, Akira
    [J]. NONLINEAR DYNAMICS, 2017, 88 (04) : 2915 - 2932
  • [23] Parametric Analysis of Magnetorheologically Damped Pendulum Vibration Absorber
    Kecik, Krzysztof
    Kapitaniak, Marcin
    [J]. INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2014, 14 (08)
  • [24] Suspension-type tuned mass dampers with varying pendulum length to dissipate energy
    Lai, Yong-An
    Yang, C. S. Walter
    Lien, Kuan-Hua
    Chung, Lap-Loi
    Wu, Lai-Yun
    [J]. STRUCTURAL CONTROL & HEALTH MONITORING, 2016, 23 (10) : 1218 - 1236
  • [25] Experiment and Simulation Study on Vibration Control of an Ancient Pagoda with Damping Devices
    Li, Tao
    Wang, Sheliang
    Yang, Tao
    [J]. INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2018, 18 (10)
  • [26] Mitigation of wind-induced response of Shanghai Center Tower by tuned mass damper
    Lu, Xilin
    Chen, Junru
    [J]. STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2011, 20 (04) : 435 - 452
  • [27] Experimental Comparison of Dynamic Behavior of Structures with a Particle Damper and a Tuned Mass Damper
    Lu, Zheng
    Huang, Biao
    Wang, Zixin
    Zhou, Ying
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (12)
  • [28] Optimal Auxiliary Functions Method for a Pendulum Wrapping on Two Cylinders
    Marinca, Vasile
    Herisanu, Nicolae
    [J]. MATHEMATICS, 2020, 8 (08)
  • [29] Study of the Apsidal Precession of the Physical Symmetrical Pendulum
    Maya, Hector R.
    Diaz, Rodolfo A.
    Herrera, William J.
    [J]. JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 2015, 82 (02):
  • [30] Adaptive passive, semiactive, smart tuned mass dampers: identification and control using empirical mode decomposition, hilbert transform, and short-term fourier transform
    Nagarajaiah, S.
    [J]. STRUCTURAL CONTROL & HEALTH MONITORING, 2009, 16 (7-8) : 800 - 841