Performance researches and improvements on heat regenerative adsorption refrigerator and heat pump

被引:63
|
作者
Wang, RZ [1 ]
Wu, JY [1 ]
Xu, YX [1 ]
Wang, W [1 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200030, Peoples R China
关键词
adsorption; refrigerator; heat pump; heat regenerative; performance research; improvement;
D O I
10.1016/S0196-8904(99)00189-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
A heat regenerative adsorption refrigerator using spiral plate heat exchangers as adsorbers and an adsorption heat Dump for air conditioning using plate fin heat exchangers or plate fin shell and tube type heat exchangers as adsorbers have been developed and researched. Experimental research results are shown. The activated carbon-methanol adsorption pair is used for the two kinds of adsorption systems. With a heat source temperature of 100 degrees C, the refrigerator achieved a refrigeration power density of more than 2.6 kg ice per day per kg activated carbon with a coefficient of performance (COP) of 0.13, and the heat pump achieved 150 W/kg activated carbon for air conditioning with a COP of about 0.4. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:233 / 249
页数:17
相关论文
共 50 条
  • [1] Performance study of heat regenerative adsorption refrigerator and heat pump
    Wang, RZ
    Xu, YX
    Wu, JY
    Wang, W
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR 98, 1998, : 159 - 162
  • [2] Experiments and improvement on heat regenerative adsorption refrigerator and heat pump
    Wang, Ruzhu
    Wu, Jingyi
    Xu, Yuxiong
    Wang, Wen
    Gui, Yubin
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 1999, 20 (04): : 364 - 369
  • [3] Experiments on heat-regenerative adsorption refrigerator and heat pump
    Wang, RZ
    Xu, YX
    Wu, JY
    Wang, W
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1998, 22 (11) : 935 - 941
  • [4] A continuous heat regenerative adsorption refrigerator using spiral plate heat exchanger as adsorbers: Improvements
    Wang, RZ
    Wu, JY
    Xu, YX
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (01): : 14 - 19
  • [5] Test on a continuous heat regenerative adsorption heat pump for performance improvement
    Wu, Jingyi
    Wang, Ruzhu
    Xu, Yuxiong
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2000, 21 (02): : 198 - 203
  • [6] Dynamic simulation and experiments of a heat regenerative adsorption heat pump
    Wu, JY
    Wang, RZ
    Xu, YX
    ENERGY CONVERSION AND MANAGEMENT, 2000, 41 (10) : 1007 - 1018
  • [7] Performance and improvements in heat pump dryers
    Alves, O
    Strommen, I
    DRYING '96, VOL A, 1996, : 405 - 416
  • [8] Performance of a thermoelectric heat pump with recirculation and regenerative heat recovery
    Hou, Benzhi
    Zheng, Yihua
    Xing, Luyi
    Song, Qinglu
    APPLIED THERMAL ENGINEERING, 2023, 223
  • [9] Experiment on a continuous heat regenerative adsorption refrigerator using spiral plate heat exchanger as adsorbers
    Wang, RZ
    Wu, JY
    Xu, YX
    Teng, Y
    Shi, W
    APPLIED THERMAL ENGINEERING, 1998, 18 (1-2) : 13 - 23
  • [10] Performance modeling and testing on a heat-regenerative adsorptive reversible heat pump
    Gui, YB
    Wang, RZ
    Wang, W
    Wu, JY
    Xu, YX
    APPLIED THERMAL ENGINEERING, 2002, 22 (03) : 309 - 320