Radiation shielding design for C-ADS inject I

被引:0
作者
Ma Zhong-Jian [1 ]
Wang Qing-Bin [1 ]
Wu Qing-Biao [1 ]
Zhang Gang [1 ]
机构
[1] Inst High Energy Phys, Beijing 100049, Peoples R China
来源
NUCLEAR SCIENCE AND TECHNIQUES | 2014年 / 25卷
关键词
Monte Carlo Simulation; Radiation Shielding; FLUKA;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Radiation shielding structure for C-ADS Inject-I was designed and optimized using FLUKA code. For this equipment was planned to be established in an existing tunnel hall and installed in limited space, several shielding hot spots are re-designed and analyzed respectively as they may cause radiation dose leakage and weakening of the total shielding effect. Besides, some new shielding structures are applied in the simulation process. All designed shielding strictures are discussed in this paper and the results will meet the governmental criteria for radiation protection.
引用
收藏
页数:4
相关论文
共 6 条
[1]  
Alfredo F, 2011, FLUKA MULTIPARTICLE
[2]  
Doll W, 1998, LINAC98
[3]   Design and analysis of the tunnel connecting the beamcorridor and the spectrum hall of the CSNS [J].
Liu Jian ;
Wang Qing-Bin ;
Wu Qing-Biao ;
Ma Zhong-Jian .
CHINESE PHYSICS C, 2011, 35 (01) :104-108
[4]  
Van Hagan T, 1998, LINAC98
[5]   Study on induced radioactivity of China Spallation Neutron Source [J].
Wu Qing-Biao ;
Wang Qing-Bin ;
Wu Jing-Min ;
Ma Zhong-Jian .
CHINESE PHYSICS C, 2011, 35 (06) :596-602
[6]  
Xu K Z, 1981, PARTICLE DETECTION T, P330