High frequency ultrasound measurement of digital dermal thickness in systemic sclerosis

被引:85
作者
Kaloudi, Olga [1 ]
Bandinelli, Francesca [1 ]
Filippucci, Emilio [2 ]
Conforti, Maria Letizia [1 ]
Miniati, Irene [1 ]
Guiducci, Serena [1 ]
Porta, Francesco [1 ]
Candelieri, Antonio [3 ]
Conforti, Domenico [3 ]
Grassiri, Genesio [4 ]
Grassi, Walter [2 ]
Matucci-Cerinic, Marco [1 ]
机构
[1] Univ Florence, Ctr Denothe, Div Rheumatol AOUC, Dept Biomed, I-50139 Florence, Italy
[2] Univ Marche, Div Rheumatol, Ancona, Italy
[3] Univ Calabria, Dept Elect Informat & Syst, Lab Decis Engn Hlth Care Delivery, I-87036 Cosenza, Italy
[4] Esaote, Genoa, Italy
关键词
RODNAN SKIN SCORE; INVOLVEMENT; SCLERODERMA;
D O I
10.1136/ard.2009.114843
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Currently, assessment of dermal thickness in systemic sclerosis (SSc) is performed by palpation and assessment using the modified Rodnan skin score (mRSS). Objective To verify whether high frequency ultrasound (US) may be a reliable and a reproducible method to measure digital dermal thickness. Methods In 70 patients with SSc, skin thickness was evaluated with US by 2 observers at 2 different sites on the second digit of the dominant limb to determine the interobserver variability. Patients and controls were examined twice by the first observer for intraobserver variability. Patients were divided into three subgroups according to the phase of the disease (oedematous, fibrotic or atrophic). Results At both examined areas, US showed a significant dermal thickening (p < 0.001) in the whole group of patients with SSc. A low intraobserver and interobserver variability was found. A highly significant correlation between the global mRSS and the local dermal thickness at the two examined sites (p = 0.032, p = 0.021) was detected. Skin thickness was significantly higher in the oedematous than in the fibrotic group (p < 0.001) and significantly higher in the fibrotic and the oedematous group (p < 0.001) than in the atrophic group (p < 0.002). Conclusions US is a reliable tool giving reproducible results, and is able to detect digital dermal thickening in SSc.
引用
收藏
页码:1140 / 1143
页数:4
相关论文
共 12 条
[1]   ULTRASOUND EXAMINATION OF SKIN THICKNESS IN PATIENTS WITH PROGRESSIVE SYSTEMIC-SCLEROSIS (SCLERODERMA) [J].
AKESSON, A ;
FORSBERG, L ;
HEDERSTROM, E ;
WOLLHEIM, F .
ACTA RADIOLOGICA-DIAGNOSIS, 1986, 27 (01) :91-94
[2]   Longitudinal development of skin involvement and reliability of high frequency ultrasound in systemic sclerosis [J].
Åkesson, A ;
Hesselstrand, R ;
Scheja, A ;
Wildt, M .
ANNALS OF THE RHEUMATIC DISEASES, 2004, 63 (07) :791-796
[3]  
CLEMENTS P, 1995, J RHEUMATOL, V22, P1281
[4]   SKIN SCORE - A SEMIQUANTITATIVE MEASURE OF CUTANEOUS INVOLVEMENT THAT IMPROVES PREDICTION OF PROGNOSIS IN SYSTEMIC-SCLEROSIS [J].
CLEMENTS, PJ ;
LACHENBRUCH, PA ;
NG, SC ;
SIMMONS, M ;
STERZ, M ;
FURST, DE .
ARTHRITIS AND RHEUMATISM, 1990, 33 (08) :1256-1263
[5]   The EUSTAR model for teaching and implementing the modified Rodnan skin score in systemic sclerosis [J].
Czirjak, Laszló ;
Nagy, Zoltán ;
Aringer, Martin ;
Riemekasten, Gabriela ;
Matucci-Cerinic, Marco ;
Furst, Daniel E. .
ANNALS OF THE RHEUMATIC DISEASES, 2007, 66 (07) :966-969
[6]  
Furst DE, 1998, J RHEUMATOL, V25, P84
[7]   High-frequency ultrasound of skin involvement in systemic sclerosis reflects oedema, extension and severity in early disease [J].
Hesselstrand, R. ;
Scheja, A. ;
Wildt, M. ;
Akesson, A. .
RHEUMATOLOGY, 2008, 47 (01) :84-87
[8]   Seventeen-point dermal ultrasound scoring system - a reliable measure of skin thickness in patients with systemic sclerosis [J].
Moore, TL ;
Lunt, M ;
McManus, B ;
Anderson, ME ;
Herrick, AL .
RHEUMATOLOGY, 2003, 42 (12) :1559-1563
[9]   SKIN THICKNESS AND COLLAGEN CONTENT IN PROGRESSIVE SYSTEMIC-SCLEROSIS AND LOCALIZED SCLERODERMA [J].
RODNAN, GP ;
LIPINSKI, E ;
LUKSICK, J .
ARTHRITIS AND RHEUMATISM, 1979, 22 (02) :130-140
[10]  
Scheja A, 1997, CLIN EXP RHEUMATOL, V15, P283