Label-free colorimetric detection of picomolar thrombin in blood plasma using a gold nanoparticle-based assay

被引:113
作者
Chen, Chuan-Kuo [3 ]
Huang, Chih-Ching [1 ,2 ]
Chang, Huan-Tsung [3 ]
机构
[1] Natl Taiwan Ocean Univ, Inst Biosci & Biotechnol, Chilung 20224, Taiwan
[2] Natl Taiwan Ocean Univ, Ctr Marine Biosci & Biotechnol, Chilung 20224, Taiwan
[3] Natl Taiwan Univ, Dept Chem, Taipei 10617, Taiwan
关键词
Biosensor; Enzyme; Gold nanoparticles; Thrombin; Colorimetric detection; ELECTROCHEMICAL DETECTION; PROTEIN; APTASENSOR; BIOSENSORS; SENSORS; GROWTH; RECOGNITION; COAGULATION; SENSITIVITY; MERCURY(II);
D O I
10.1016/j.bios.2010.01.005
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We unveil a novel, label-free, colorimetric assay - using fibrinogen (Fib) and gold nanoparticles (Au NPs) - for the highly selective and sensitive detection of thrombin. Addition of fibrinogen to a solution of Au NPs (average diameter: 56 nm) led to ready conjugation, forming Fib-Au NPs through electrostatic and hydrophobic interactions. Introduction of thrombin (a serine protease) into the Fib-Au NPs solutions in the presence of excess fibrinogen induced the formation of insoluble fibrillar fibrin-Au NPs agglutinates through the polymerization of the unconjugated and conjugated fibrinogen. After centrifugation, the absorbance at 532 nm of the supernatants decreased upon increasing the concentration of thrombin. This Fib-Au NP probe provides high sensitivity [limit of detection (LOD): 0.04 pM] for thrombin, with remarkable selectivity over other proteins and proteases. The range of linearity for the absorbance against the thrombin concentration was 0.1-10 pM (R-2 = 0.96). This approach provides an LOD for thrombin that is lower than those obtainable using other nanomaterial- and aptamer-based detection methods. We validated the utility of this Fib-Au NP probe through separate analyses of thrombin and Factor Xa at picomolar levels in plasma samples without the need for sample pretreatment. This technique appears to have practical potential in the diagnosis of diseases associated with coagulation abnormalities and cancers (e.g., pulmonary metastasis). (c) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1922 / 1927
页数:6
相关论文
共 43 条
  • [1] A novel electrochemical detection method for aptamer biosensors
    Bang, GS
    Cho, S
    Kim, BG
    [J]. BIOSENSORS & BIOELECTRONICS, 2005, 21 (06) : 863 - 870
  • [2] Detection of thrombin in human blood by ex-vivo hirudin
    Bichler, J
    Heit, JA
    Owen, WG
    [J]. THROMBOSIS RESEARCH, 1996, 84 (04) : 289 - 294
  • [3] BIGGS R, 1976, HUMAN BLOOD COAGULAT
  • [4] Analytical performances of aptamer-based sensing for thrombin detection
    Bini, Alessandra
    Minunni, Maria
    Tombelli, Sara
    Centi, Sonia
    Mascini, Marco
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (07) : 3016 - 3019
  • [5] Cans A.-S., 2007, NANOBIOTECHNOLOGY, V3, P12, DOI DOI 10.1007/S12030-007-0002-6
  • [6] Aptamer-based detection of plasma proteins by an electrochemical assay coupled to magnetic beads
    Centi, Sonia
    Tombelli, Sara
    Minunni, Maria
    Mascini, Marco
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (04) : 1466 - 1473
  • [7] Aptamer-Based SERRS Sensor for Thrombin Detection
    Cho, Hansang
    Baker, Brian R.
    Wachsmann-Hogiu, Sebastian
    Pagba, Cynthia V.
    Laurence, Ted A.
    Lane, Stephen M.
    Lee, Luke P.
    Tok, Jeffrey B. -H.
    [J]. NANO LETTERS, 2008, 8 (12) : 4386 - 4390
  • [8] Aptamer-capped nanocrystal quantum dots: A new method for label-free protein detection
    Choi, Jong Hyun
    Chen, Kok Hao
    Strano, Michael S.
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (49) : 15584 - 15585
  • [9] Label-free screening of bio-molecular interactions
    Cooper, MA
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (05) : 834 - 842
  • [10] Impedimetric Aptasensor with Femtomolar Sensitivity Based on the Enlargement of Surface-Charged Gold Nanoparticles
    Deng, Chunyan
    Chen, Jinhua
    Nie, Zhou
    Wang, Mengdong
    Chu, Xiaochen
    Chen, Xiaoli
    Xiao, Xilin
    Lei, Chunyang
    Yao, Shouzhuo
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (02) : 739 - 745