Effects of ionic and non-ionic contrast media on platelet function as evaluated by plasma concentration of beta-thromboglobulin

被引:5
作者
Brzosko, M
Cyrylowski, L
Brzosko, I
Domanski, Z
Fiedorowicz-Fabrycy, I
机构
[1] Pomeranian Med Univ, Dept Radiol, PL-71252 Szczecin, Poland
[2] Pomeranian Med Univ, Clin Dept Rheumatol, PL-71252 Szczecin, Poland
关键词
D O I
10.1259/bjr.70.840.9505842
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the study was to evaluate the effects of ionic and non-ionic contrast media on platelet function. In 44 patients who underwent angiography, the plasma concentration of beta-thromboglobulin (beta TG) was measured before and after ionic contrast medium (diatrizoate) administration in 22 patients and non-ionic contrast medium (iopromide) in the other 22 patients. A significant decrease in the plasma beta TG levels after intraarterial contrast medium injection occurred in both groups of patients. No significant beta TG level changes occurred in patients with normal pre-examination beta TG levels in both groups. In patients with elevated beta TG levels before arteriography, beta TG returned to normal values after contrast medium injection in both groups. There was no significant correlation between the amount of administered contrast medium and beta TG concentration after angiography. These results suggest that platelet function is not affected by either ionic or non-ionic contrast medium in patients with normal platelet activation. In patients with enhanced platelet activation, the activation became normal after contrast medium administration.
引用
收藏
页码:1239 / 1244
页数:6
相关论文
共 34 条
[21]   PROTEINURIA FOLLOWING NEPHROANGIOGRAPHY .6. COMPARISON BETWEEN METRIZOATE AND METRIZAMIDE IN MAN [J].
HOLTAS, S ;
ALMEN, T ;
HELLSTEN, S ;
TEJLER, L .
ACTA RADIOLOGICA-DIAGNOSIS, 1980, 21 (04) :491-494
[22]  
HOLTAS S, 1989, PATIENTS SAFETY ADVE, P97
[23]   RISK OF THROMBOEMBOLISM DURING DIAGNOSTIC AND INTERVENTIONAL CARDIAC PROCEDURES WITH NONIONIC CONTRAST-MEDIA [J].
HWANG, MH ;
PIAO, ZE ;
MURDOCK, DK ;
MESSMORE, HL ;
GIARDINA, JJ ;
SCANLON, PJ .
RADIOLOGY, 1990, 174 (02) :453-457
[24]   ADVERSE REACTIONS TO IONIC AND NONIONIC CONTRAST-MEDIA - A REPORT FROM THE JAPANESE-COMMITTEE-ON-THE-SAFETY-OF-CONTRAST MEDIA [J].
KATAYAMA, H ;
YAMAGUCHI, K ;
KOZUKA, T ;
TAKASHIMA, T ;
SEEZ, P ;
MATSUURA, K .
RADIOLOGY, 1990, 175 (03) :621-628
[25]   THROMBIN GENERATION IN NONCLOTTABLE MIXTURES OF BLOOD AND NONIONIC CONTRAST AGENTS [J].
KOPKO, PM ;
SMITH, DC ;
BULL, BS .
RADIOLOGY, 1990, 174 (02) :459-461
[26]  
PALMER FJ, 1989, INT CONGR SER, V816, P137
[27]  
PARVEZ Z, 1987, CONTRAST MEDIA BIOL, V1, P99
[28]   CHANGES IN PLATELET ACTIVITY AND TISSUE PLASMINOGEN-ACTIVATOR DURING ARTERIOGRAPHY IN PATIENTS WITH CHRONIC LIMB ISCHEMIA [J].
POLANOWSKA, R ;
WILCZYNSKA, M ;
SKAWINSKI, W ;
GOCH, JH ;
AUGUSTYNIAK, W ;
CIERNIEWSKI, CS .
THROMBOSIS RESEARCH, 1992, 65 (4-5) :663-665
[29]   ELEVATED BETA THROMBOGLOBULIN IN PERIPHERAL VENOUS-BLOOD OF PATIENTS WITH ACUTE MYOCARDIAL ISCHEMIA - DIRECT EVIDENCE FOR ENHANCED PLATELET REACTIVITY INVIVO [J].
SMITHERMAN, TC ;
MILAM, M ;
WOO, J ;
WILLERSON, JT ;
FRENKEL, EP .
AMERICAN JOURNAL OF CARDIOLOGY, 1981, 48 (03) :395-402
[30]  
SPECK U, 1991, UBERSICHT ANWENDUNG, P66