Flow Injection Analysis with Amperometric Detection for Morpholine Determination in Corrosion Inhibitors

被引:9
作者
de Oliveira, Sanair M. [1 ]
Siguemura, Angelo [1 ]
Lima, Hugo O. [1 ]
de Souza, Flavia C. [1 ]
Magalhaes, Alvaro A. O. [2 ]
Toledo, Roberta M. [2 ]
D'Elia, Eliane [1 ]
机构
[1] Univ Fed Rio de Janeiro, Inst Quim, BR-21941909 Rio De Janeiro, RJ, Brazil
[2] Petrobras SA, Ctr Pesquisas & Desenvolvimento Leopoldo Amer Mig, BR-21941915 Rio De Janeiro, RJ, Brazil
关键词
morpholine; corrosion inhibitors; amperometry; screen-printed electrodes; flow injection analysis; CHROMATOGRAPHIC DETERMINATION; MILD-STEEL; GAS; CYCLOHEXYLAMINE; DERIVATIVES; WATER; PARACETAMOL; ELECTRODES; QUINOLINE; AMINES;
D O I
10.5935/0103-5053.20140122
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, an electrochemical method is proposed using flow injection analysis and amperometric detection with screen-printed carbon electrodes for morpholine determination to monitor the quality of morpholine-based commercial inhibitors and the residual concentration of inhibitors that control internal corrosion in oil industry pipelines. The amperometric method resulted in a strong linear correlation coefficient (r = 0.9941) with a linear response over a concentration range of 20-120 mg L-1, a limit of detection of 10 mg L-1 and a limit of quantification of 30 mg L-1. In addition, the method has been shown to be precise, linear and homoscedastic. The recovery for the amperometric method was 100 +/- 6%, and the recovery for the real condensate sample was 99 +/- 2%. Thus, the proposed method is promising for analysing morpholine-based commercial inhibitors in oil industry pipelines with simple and low-cost methodologies compared with ion chromatography techniques.
引用
收藏
页码:1399 / 1406
页数:8
相关论文
共 28 条
[1]  
[Anonymous], 2001, PEABODYS CONTROL PIP
[2]  
[Anonymous], 1993, Statistics for Analytical Chemistry
[3]   Determination of paracetamol at a graphite-polyurethane composite electrode as an amperometric flow detector [J].
Cervini, Priscila ;
Gomes Cavalheiro, Eder Tadeu .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2008, 19 (05) :836-841
[4]   Voltammetric Determination of BHT Antioxidant at Gold Electrode in Biodiesel [J].
Chylkova, Jaromira ;
Tomaskova, Marketa ;
Mikysek, Tomas ;
Selesovska, Renata ;
Jehlicka, Jan .
ELECTROANALYSIS, 2012, 24 (06) :1374-1379
[5]  
Corrosion Costs and Preventive Strategies in the United States, 2002, MAT PERFORMANCE S
[6]   Flow injection analysis with amperometric detection for iodide determination as a tracer in seawater reservoirs [J].
de Souza, Flavia C. ;
Izidro da Silva, Davi Augusto ;
Simoes, Marcia ;
Faria, Roberto Barros ;
de Melo, Maria Aparecida ;
Toledo, Roberta Maciel ;
D'Elia, Eliane .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 2012, 42 (08) :585-593
[7]  
Ebenso EE, 2010, INT J ELECTROCHEM SC, V5, P1574
[8]   Theoretical Studies of Some Sulphonamides as Corrosion Inhibitors for Mild Steel in Acidic Medium [J].
Ebenso, Eno E. ;
Arslan, Taner ;
Kandemirli, Fatma ;
Love, Ian ;
Odretir, Cemil ;
Saracoglu, Murat ;
Umoren, Saviour A. .
INTERNATIONAL JOURNAL OF QUANTUM CHEMISTRY, 2010, 110 (14) :2614-2636
[9]   Electroanalytical techniques for the determination of pesticides in foods. [J].
Galli, A ;
De Souza, D ;
Garbellini, GS ;
Coutinho, CFB ;
Mazo, LH ;
Avaca, LA ;
Machado, SAS .
QUIMICA NOVA, 2006, 29 (01) :105-112
[10]   ION CHROMATOGRAPHIC DETERMINATION OF MORPHOLINE AND CYCLOHEXYLAMINE INE IN AQUEOUS-SOLUTIONS CONTAINING AMMONIA AND HYDRAZINE [J].
GILBERT, R ;
RIOUX, R ;
SAHEB, SE .
ANALYTICAL CHEMISTRY, 1984, 56 (01) :106-109