Streak Metal Artifact Reduction Based on Sinogram Fusion and Tissue-Class Model in CT Images
被引:0
|
作者:
Deng, Shuwen
论文数: 0引用数: 0
h-index: 0
机构:
Hubei Univ Sci & Technol, Comp Dept, Xianning 437100, Peoples R ChinaHubei Univ Sci & Technol, Comp Dept, Xianning 437100, Peoples R China
Deng, Shuwen
[1
]
Li, Yuanjin
论文数: 0引用数: 0
h-index: 0
机构:
Chuzhou Univ, Comp Dept, Chuzhou 239000, Peoples R ChinaHubei Univ Sci & Technol, Comp Dept, Xianning 437100, Peoples R China
Li, Yuanjin
[2
]
Wang, Dianhua
论文数: 0引用数: 0
h-index: 0
机构:
Hubei Univ Sci & Technol, Comp Dept, Xianning 437100, Peoples R ChinaHubei Univ Sci & Technol, Comp Dept, Xianning 437100, Peoples R China
Wang, Dianhua
[1
]
机构:
[1] Hubei Univ Sci & Technol, Comp Dept, Xianning 437100, Peoples R China
[2] Chuzhou Univ, Comp Dept, Chuzhou 239000, Peoples R China
来源:
WIRELESS COMMUNICATIONS & MOBILE COMPUTING
|
2022年
/
2022卷
基金:
中国国家自然科学基金;
关键词:
ALGORITHM;
D O I:
10.1155/2022/8021862
中图分类号:
TP [自动化技术、计算机技术];
学科分类号:
0812 ;
摘要:
The presence of streak metal artifacts seriously degrades the diagnostic value and deteriorates the qualities of CT images. Analyzing the causes and classical streak metal artifact reduction (MAR) methods, the paper proposes the streak metal artifact reduction method based on sinogram fusion and tissue-class mode for CT images (F-MAR). Firstly, the original CT images are corrected using a linear interpolation streak metal artifact reduction (L-MAR) scheme in the raw data domain. Subsequently, to preserve the edge information, the metal artifact-reduced images are then smoothed into smoothed images (tissue-class model) by using the mean filter. Segment the original CT image that contained the streak artifacts. The original CT image and the CT image that contained high-density material are projected into the original sinogram and the high density material sinogram, respectively. Secondly, the simple linear interpolation is used to correct the CT original CT image into the corrected CT image. The mean filter is applied in the corrected CT image. The corrected CT image is projected into the corrected sinogram. Thirdly, according to the position of the high density material sinogram located in the original sinogram and the corrected sinogram, the original position sinogram included in the original sinogram and the corrected position sinogram included in the corrected sinogram are, respectively, obtained. The two sinograms are fused into the fused sinogram. The fused sinogram, the original sinogram, and the high-density material sinogram are fused into the final sinogram. Finally, the filtered back projection reconstruction algorithm is used to reconstruct the final sinogram into the reconstructed CT image. The reconstructed CT image and high density material image are fused into the final image. The experimentation results show that the method proposed in the paper can obtain better correction effect than the classical correction methods in vision.
机构:
Yonsei Univ, Yonsei Canc Ctr, Heavy Ion Res Inst, Dept Radiat Oncol,Coll Med, 50-1 Yonsei Ro, Seoul 03722, South KoreaYonsei Univ, Yonsei Canc Ctr, Heavy Ion Res Inst, Dept Radiat Oncol,Coll Med, 50-1 Yonsei Ro, Seoul 03722, South Korea
Kim, Hojin
Yoo, Sang Kyun
论文数: 0引用数: 0
h-index: 0
机构:
Yonsei Univ, Yonsei Canc Ctr, Heavy Ion Res Inst, Dept Radiat Oncol,Coll Med, 50-1 Yonsei Ro, Seoul 03722, South KoreaYonsei Univ, Yonsei Canc Ctr, Heavy Ion Res Inst, Dept Radiat Oncol,Coll Med, 50-1 Yonsei Ro, Seoul 03722, South Korea
Yoo, Sang Kyun
Kim, Dong Wook
论文数: 0引用数: 0
h-index: 0
机构:
Yonsei Univ, Yonsei Canc Ctr, Heavy Ion Res Inst, Dept Radiat Oncol,Coll Med, 50-1 Yonsei Ro, Seoul 03722, South KoreaYonsei Univ, Yonsei Canc Ctr, Heavy Ion Res Inst, Dept Radiat Oncol,Coll Med, 50-1 Yonsei Ro, Seoul 03722, South Korea
Kim, Dong Wook
论文数: 引用数:
h-index:
机构:
Lee, Ho
论文数: 引用数:
h-index:
机构:
Hong, Chae-Seon
Han, Min Cheol
论文数: 0引用数: 0
h-index: 0
机构:
Yonsei Univ, Yonsei Canc Ctr, Heavy Ion Res Inst, Dept Radiat Oncol,Coll Med, 50-1 Yonsei Ro, Seoul 03722, South KoreaYonsei Univ, Yonsei Canc Ctr, Heavy Ion Res Inst, Dept Radiat Oncol,Coll Med, 50-1 Yonsei Ro, Seoul 03722, South Korea
Han, Min Cheol
Kim, Jin Sung
论文数: 0引用数: 0
h-index: 0
机构:
Yonsei Univ, Yonsei Canc Ctr, Heavy Ion Res Inst, Dept Radiat Oncol,Coll Med, 50-1 Yonsei Ro, Seoul 03722, South KoreaYonsei Univ, Yonsei Canc Ctr, Heavy Ion Res Inst, Dept Radiat Oncol,Coll Med, 50-1 Yonsei Ro, Seoul 03722, South Korea