Streak Metal Artifact Reduction Based on Sinogram Fusion and Tissue-Class Model in CT Images

被引:0
|
作者
Deng, Shuwen [1 ]
Li, Yuanjin [2 ]
Wang, Dianhua [1 ]
机构
[1] Hubei Univ Sci & Technol, Comp Dept, Xianning 437100, Peoples R China
[2] Chuzhou Univ, Comp Dept, Chuzhou 239000, Peoples R China
来源
WIRELESS COMMUNICATIONS & MOBILE COMPUTING | 2022年 / 2022卷
基金
中国国家自然科学基金;
关键词
ALGORITHM;
D O I
10.1155/2022/8021862
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The presence of streak metal artifacts seriously degrades the diagnostic value and deteriorates the qualities of CT images. Analyzing the causes and classical streak metal artifact reduction (MAR) methods, the paper proposes the streak metal artifact reduction method based on sinogram fusion and tissue-class mode for CT images (F-MAR). Firstly, the original CT images are corrected using a linear interpolation streak metal artifact reduction (L-MAR) scheme in the raw data domain. Subsequently, to preserve the edge information, the metal artifact-reduced images are then smoothed into smoothed images (tissue-class model) by using the mean filter. Segment the original CT image that contained the streak artifacts. The original CT image and the CT image that contained high-density material are projected into the original sinogram and the high density material sinogram, respectively. Secondly, the simple linear interpolation is used to correct the CT original CT image into the corrected CT image. The mean filter is applied in the corrected CT image. The corrected CT image is projected into the corrected sinogram. Thirdly, according to the position of the high density material sinogram located in the original sinogram and the corrected sinogram, the original position sinogram included in the original sinogram and the corrected position sinogram included in the corrected sinogram are, respectively, obtained. The two sinograms are fused into the fused sinogram. The fused sinogram, the original sinogram, and the high-density material sinogram are fused into the final sinogram. Finally, the filtered back projection reconstruction algorithm is used to reconstruct the final sinogram into the reconstructed CT image. The reconstructed CT image and high density material image are fused into the final image. The experimentation results show that the method proposed in the paper can obtain better correction effect than the classical correction methods in vision.
引用
收藏
页数:7
相关论文
共 26 条
  • [1] Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering
    Bal, Matthieu
    Spies, Lothar
    MEDICAL PHYSICS, 2006, 33 (08) : 2852 - 2859
  • [2] A metal artifact reduction scheme in CT by a Poisson fusion sinogram based postprocessing method
    Tang, Hui
    Lin, Yu Bing
    Sun, Guo Yan
    Bao, Xu Dong
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2021, 29 (02) : 245 - 257
  • [3] Image-based metal artifact reduction in CT images
    Serifovic-Trbalic, A.
    Trbalic, A.
    2016 39TH INTERNATIONAL CONVENTION ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONICS AND MICROELECTRONICS (MIPRO), 2016, : 442 - 446
  • [4] Metal artifact reduction in CT using fusion based prior image
    Wang, Jun
    Wang, Shijie
    Chen, Yang
    Wu, Jiasong
    Coatrieux, Jean-Louis
    Luo, Limin
    MEDICAL PHYSICS, 2013, 40 (08)
  • [5] Metal Artifact Reduction in CT-Based Attenuation Correction of PET using Sobolev Sinogram Restoration
    Mehranian, A.
    Ay, M. R.
    Rahmim, A.
    Zaidi, H.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2936 - 2942
  • [6] Gaussian diffusion sinogram inpainting for X-ray CT metal artifact reduction
    Peng, Chengtao
    Qiu, Bensheng
    Li, Ming
    Guan, Yihui
    Zhang, Cheng
    Wu, Zhongyi
    Zheng, Jian
    BIOMEDICAL ENGINEERING ONLINE, 2017, 16
  • [7] Metal artifact reduction in spiral fan-beam CT using a new sinogram segmentation scheme
    Yazdi, Mehran
    Mansourian, Zohre
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (05) : 737 - 749
  • [8] Metal Artifact Reduction in Dental CBCT Images Using Direct Sinogram Correction Combined with Metal Path-Length Weighting
    Hegazy, Mohamed A. A.
    Cho, Myung Hye
    Cho, Min Hyoung
    Lee, Soo Yeol
    SENSORS, 2023, 23 (03)
  • [9] Evaluation of the quality of CT images acquired with smart metal artifact reduction software
    Zhou, Peng
    Zhang, Chunling
    Gao, Zhen
    Cai, Wangshu
    Yan, Deyue
    Wei, Zhaolong
    OPEN LIFE SCIENCES, 2018, 13 (01): : 155 - 162
  • [10] Metal artifact reduction for CT-based luggage screening
    Karimi, Seemeen
    Martz, Harry
    Cosman, Pamela
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2015, 23 (04) : 435 - 451