The use of cyclic voltammetry for wine analysis: Determination of polyphenols and free sulfur dioxide

被引:127
作者
Makhotkina, Olga [1 ]
Kilmartin, Paul A. [1 ]
机构
[1] Univ Auckland, Dept Chem, Wine Sci Programme, Auckland, New Zealand
关键词
Cyclic voltammetry; Wine; Phenolics; Adsorption; Sulfur dioxide; Total polyphenols; ANTIOXIDANT ACTIVITY; PHENOLIC COMPOSITION; WHITE WINES; ELECTROCHEMICAL SENSOR; STRIPPING VOLTAMMETRY; OXIDATION; SULFITE; RUTIN; ELECTRODES; OXYGEN;
D O I
10.1016/j.aca.2010.03.064
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of cyclic voltammetry to characterize wines and wine polyphenols in a pH 3.3 model wine solution has been extended to take into account the effects of sulfur dioxide and polyphenol adsorption processes. A good correlation was obtained between a cyclic voltammetric measure, based upon the response produced before and after acetaldehyde additions, and the concentration of free sulfur dioxide in eight white wines (r(2)=0.974). By the addition of acetaldehyde to the white wines, an important new step in the methodology, the area under the anodic scan in the potential range from 100 to 1200 mV (Ag/AgCI) closely matched the spectroscopic measure of total polyphenols (absorbance at 280 nm) for the white wines, when both were measured in terms of caffeic acid equivalents (r(2)=0.949). The anodic peak area accounted for about 70% of the 280 nm total phenols measure, in catechin equivalents, for the red wines, and a good linear correlation was also obtained (r(2)=0.942). The level of catechol and galloyl-containing polyphenols in the wines was calculated by measuring the size of the first anodic peak at around 450 mV after treatment of the wines with acetaldehyde; the peak current correlated well with the total caffeic acid derivatives in the white wines determined by HPLC (r(2)=0.982). The concentration of flavonols was estimated by selective adsorption of these compounds onto the carbon electrode and determining the anodic peak current at 1120 mV, with good correlations obtained when compared to total flavonols as measured by HPLC (r(2)=0.984 for the red wines, and r(2)=0.987 for the white wines). (c) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:155 / 165
页数:11
相关论文
共 57 条
[1]  
[Anonymous], 1995, MAKING GOOD WINE MAN
[2]  
Bard A.J, 2002, Student Solutions Manual to accompany Electrochemical Methods: Fundamentals and Applicaitons, V2e
[3]  
Blanchard L, 2004, AM J ENOL VITICULT, V55, P115
[4]   Electrochemical oxidation of quercetin [J].
Brett, AMO ;
Ghica, ME .
ELECTROANALYSIS, 2003, 15 (22) :1745-1750
[5]   Determination of sulfite by flow injection analysis using a poly [Ni-(protoporphyrin IX)] chemically modified electrode [J].
Carballo, R ;
Dall'Orto, VC ;
Lo Balbo, A ;
Rezzano, I .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 88 (02) :155-161
[6]   Amperometric detection of sulfur-containing compounds in alkaline media [J].
Casella, IG ;
Contursi, M ;
Desimoni, E .
ANALYST, 2002, 127 (05) :647-652
[7]   Amperometric and potentiometric determination of catechin as model of polyphenols in wines [J].
Castaignède, V ;
Durliat, H ;
Comtat, M .
ANALYTICAL LETTERS, 2003, 36 (09) :1707-1720
[8]  
Danilewicz JC, 2003, AM J ENOL VITICULT, V54, P73
[9]  
De Beer D, 2004, AM J ENOL VITICULT, V55, P389
[10]   Reagentless system for sulphite determination based on polyaniline [J].
de Marcos, S ;
Alcubierre, N ;
Galbán, J ;
Castillo, JR .
ANALYTICA CHIMICA ACTA, 2004, 502 (01) :7-13