On Line Detection of Inverter Fed AC Machine Insulation Health State using High Frequency Voltage Excitation

被引:0
作者
Wolbank, Th. M. [1 ]
机构
[1] Vienna Univ Technol, Inst Energy Syst & Elect Drives, A-1040 Vienna, Austria
来源
2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE) | 2015年
关键词
AC machines; Fault diagnosis; Insulation; Electric breakdown; SYSTEMS;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Condition monitoring is gaining more and more importance in the past few years. As inverter fed operation puts additional stress on the machine's insulation system a breakdown of a drive system associated with costly outage of industrial processes or production plants is getting more likely. To enable a monitoring of the insulation system health state before an actual short circuit and breakdown occurs extensive test procedures are usually necessary that need both, additional equipment as well as disconnected drive. In order to enable a continuous monitoring a method is presented that enables the detection of changes in the machines insulation system during operation of the inverter. The method is based on a voltage excitation of the machine with a specific frequency range and measuring the corresponding current reaction. By observing changes at a specific frequency range, an insulation health indicator can be calculated that is able to detect deteriorations before an actual short circuit establishes. No additional sensors or measurement equipment is needed and the method can be implemented in modern inverter fed drives with minimum changes of configuration.
引用
收藏
页码:4084 / 4090
页数:7
相关论文
共 10 条
  • [1] [Anonymous], 1985, IEEE T IND APPL
  • [2] [Anonymous], 1985, IEEE T IND APPL
  • [3] Behavior of Machine Insulation Systems Subjected to Accelerated Thermal Aging Test
    Farahani, M.
    Gockenbach, E.
    Borsi, H.
    Schaefer, K.
    Kaufhold, M.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (05) : 1364 - 1372
  • [4] Study of capacitance and dissipation factor tip-up to evaluate the condition of insulating systems for high voltage rotating machines
    Farahani, Mohsen
    Borsi, Hossein
    Gockenbach, Ernst
    [J]. ELECTRICAL ENGINEERING, 2007, 89 (04) : 263 - 270
  • [5] A Survey on Testing and Monitoring Methods for Stator Insulation Systems of Low-Voltage Induction Machines Focusing on Turn Insulation Problems
    Grubic, Stefan
    Aller, Jose M.
    Lu, Bin
    Habetler, Thomas G.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (12) : 4127 - 4136
  • [6] Liu Y, 2014, INT C ELECTR MACH SY, P638, DOI 10.1109/ICEMS.2014.7013565
  • [7] Nussbaumer P, 2012, IEEE IND ELEC, P1678, DOI 10.1109/IECON.2012.6388723
  • [8] Oslinger J.L., 2012, WORLD ACAD SCI ENG T, V63, P365
  • [9] A new method for ac machine turn insulation diagnostic based on high frequency resonances
    Perisse, Frederic
    Werynski, Piotr
    Roger, Daniel
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (05) : 1308 - 1315
  • [10] Vendrusculo EA, 2001, APPL POWER ELECT CO, P622, DOI 10.1109/APEC.2001.911712