Mitigation of Temperature-Induced Light-Shift Effects in Miniaturized Atomic Clocks

被引:19
作者
Vicarini, Remy [1 ,2 ]
Hafiz, Moustafa Abdel [1 ,3 ]
Maurice, Vincent [1 ,4 ]
Passilly, Nicolas [1 ]
Kroemer, Eric [2 ]
Ribetto, Luca [2 ]
Gaff, Vincent [2 ]
Gorecki, Christophe [1 ]
Galliou, Serge [1 ]
Boudot, Rodolphe [1 ]
机构
[1] UTBM, FEMTO ST, ENSMM, CNRS,UBFC, F-25030 Besancon, France
[2] Tron Microsyst, F-38926 Crolles, France
[3] PTB, Braunschweig, Germany
[4] NIST, Boulder, CO USA
关键词
Vertical cavity surface emitting lasers; Clocks; Masers; Laser stability; Temperature sensors; Photodiodes; Computer architecture; frequency control; spectroscopy; and vertical-cavity surface-emitting lasers (VCSELs); LONG-TERM STABILITY; VAPOR CELLS; FREQUENCY;
D O I
10.1109/TUFFC.2019.2933051
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The demonstration of miniature atomic clocks (MACs) based on coherent population trapping (CPT) with improved mid- and long-term frequency stability benefits from the implementation of additional stabilization loops to reduce temperature-induced light-shift effects. In this article, we report and highlight the individual and combined benefits of such servo loops on the frequency stability of a CPT-based MAC. The first loop stabilizes the actual temperature of the vertical-cavity surface-emitting laser (VCSEL) chip using a compensation method in which the reading of external temperature variations is derived from the atomic vapor output signal. The second loop maintains the total microwave power absorbed by the laser to a value that maximizes the optical absorption and significantly reduces the laser power dependence of the clock frequency. Experimental tests are performed onto a miniaturized CPT-clock physics package using a chip-VCSEL tuned on the Cs D-1 line (lambda = 895 nm). The VCSEL temperature compensation technique improves, by a factor of 4, the Allan deviation of the clock at 10(4) s. The simultaneous operation of both servo loops improves, by a factor of 7, the clock fractional frequency stability at 10(4) s. The clock demonstrates a fractional frequency stability of 7.5 x 10(-11) at 1 s and better than 2 x 10(-11) at 1 day.
引用
收藏
页码:1962 / 1967
页数:6
相关论文
共 31 条
  • [1] Aging studies on micro-fabricated alkali buffer-gas cells for miniature atomic clocks
    Abdullah, S.
    Affolderbach, C.
    Gruet, F.
    Mileti, G.
    [J]. APPLIED PHYSICS LETTERS, 2015, 106 (16)
  • [2] Low helium permeation cells for atomic microsystems technology
    Dellis, Argyrios T.
    Shah, Vishal
    Donley, Elizabeth A.
    Knappe, Svenja
    Kitching, John
    [J]. OPTICS LETTERS, 2016, 41 (12) : 2775 - 2778
  • [3] Deng J., 2005, U.S. Patent, Patent No. [6 927 636 B2, 6927636]
  • [4] GALLIOU S, 1995, IEEE T ULTRASON FERR, V42, P832, DOI 10.1109/58.464839
  • [5] Karlen S, 2018, 2018 EUROPEAN FREQUENCY AND TIME FORUM (EFTF), P91, DOI 10.1109/EFTF.2018.8409005
  • [6] Lifetime assessment of RbN3-filled MEMS atomic vapor cells with Al2O3 coating
    Karlen, Sylvain
    Gobet, Jean
    Overstolz, Thomas
    Haesler, Jacques
    Lecomte, Steve
    [J]. OPTICS EXPRESS, 2017, 25 (03): : 2187 - 2194
  • [7] Miniature vapor-cell atomic-frequency references
    Kitching, J
    Knappe, S
    Hollberg, L
    [J]. APPLIED PHYSICS LETTERS, 2002, 81 (03) : 553 - 555
  • [8] Atomic vapor cells for chip-scale atomic clocks with improved long-term frequency stability
    Knappe, S
    Gerginov, V
    Schwindt, PDD
    Shah, V
    Robinson, HG
    Hollberg, L
    Kitching, J
    [J]. OPTICS LETTERS, 2005, 30 (18) : 2351 - 2353
  • [9] A microfabricated atomic clock
    Knappe, S
    Shah, V
    Schwindt, PDD
    Hollberg, L
    Kitching, J
    Liew, LA
    Moreland, J
    [J]. APPLIED PHYSICS LETTERS, 2004, 85 (09) : 1460 - 1462
  • [10] Knappe S., 2008, Comprehensive Microsystems, P571