Reactive paper spray mass spectrometry for in situ identification of quinones

被引:36
|
作者
Zhou, Xuan [1 ]
Pei, Jiying [1 ]
Huang, Guangming [1 ]
机构
[1] Univ Sci & Technol China, Dept Chem, Sch Chem & Mat Sci, Hefei 230026, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
POLYCYCLIC AROMATIC-HYDROCARBONS; DESORPTION ELECTROSPRAY-IONIZATION; PERFORMANCE LIQUID-CHROMATOGRAPHY; DERIVATIZATION REAGENT; AMBIENT CONDITIONS; COMPLEX-MIXTURES; 9,10-PHENANTHRENEQUINONE; URINE; CELLS;
D O I
10.1002/rcm.7092
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RATIONALEThe polycyclic aromatic hydrocarbons quinones are reported to be harmful and could cause mutations and cancer via the generation of reactive oxygen species through their redox cycle in human body. For detection by gas chromatography and high-performance liquid chromatography mass spectrometry (MS), sample pretreatments and chromatographic separation prior to MS are generally required, which makes the whole analytical process laborious and time-consuming, resulting in difficulties for fast screening targets from complicated matrices. Thus facile, rapid and reliable MS methods for detection of quinones in complicated matrices are in great demand. METHODSReactive paper spray mass spectrometry is reported for rapid identification and quantification of quinones in complicated matrices. The method is based on an in situ derivatization reaction between cysteamine and quinones prior to analysis with paper spray mass spectrometry. With the addition of an easily charged chemical tag, the ionization efficiency of analysts is greatly improved. Due to the high ionization efficiency of the drivatives, quinones in complicated matrices could be detected rapidly without any pretreatment. RESULTSUnder the optimized experimental conditions, the linear dynamic ranges for both 1,4-benzoquinone and 1,4-naphthoquinone are 0.4-40ng and that for 1,4-anthraquinone is 0.4-20ng. Limits of detection for these three analytes were measured to be 160, 40 and 200pg using methyl-p-benzoquinone as internal standard. The capability to conduct MS analysis under ambient pressure is illustrated by identification of 1,4-naphthoquinone and 1,4-anthraquinone in raw urine, raw serum and cell culture medium. CONCLUSIONSReactive paper spray could be applied to fast screening of quinones from complicated matrices. Therefore, we believe that reactive paper spray mass spectrometry might be potentially useful in the fields of environmental sciences, metabolomics and clinic analysis. Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:100 / 106
页数:7
相关论文
共 50 条
  • [1] Biogenic aldehyde determination by reactive paper spray ionization mass spectrometry
    Bag, Soumabha
    Hendricks, P. I.
    Reynolds, J. C.
    Cooks, R. G.
    ANALYTICA CHIMICA ACTA, 2015, 860 : 37 - 42
  • [2] In Situ Separation and Analysis of Lipids by Paper Spray Ionization Mass Spectrometry
    Kal, Youngju
    Cha, Sangwon
    MOLECULES, 2021, 26 (01):
  • [3] Reactive paper spray mass spectrometry for rapid analysis of formaldehyde in facial masks
    Song, Wenwen
    Wang, Yuanchao
    Huang, Lili
    Cheng, Heyong
    Wu, Jun
    Pan, Yuanjiang
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2019, 33 (12) : 1091 - 1096
  • [4] Reactive Paper Spray Ionization Mass Spectrometry for Rapid Detection of Estrogens in Cosmetics
    Song, Dongning
    Liu, Jing
    Liu, Yang
    MOLECULES, 2023, 28 (15):
  • [5] Identification and Mitigation of Pyrolysis Products in Laser-Cut Paper for Paper Spray Mass Spectrometry
    Rydberg, Magnus
    Ochoa, Alexis
    Campos, Katherine Dayana Barrera
    Skaggs, Christine
    Rael, Ashur
    Manicke, Nicholas
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2025, 36 (04) : 829 - 838
  • [6] Direct Analysis and Quantification of Metaldehyde in Water using Reactive Paper Spray Mass Spectrometry
    Maher, Simon
    Jjunju, Fred P. M.
    Damon, Deidre E.
    Gorton, Hannah
    Maher, Yosef S.
    Syed, Safaraz U.
    Heeren, Ron M. A.
    Young, Iain S.
    Taylor, Stephen
    Badu-Tawiah, Abraham K.
    SCIENTIFIC REPORTS, 2016, 6
  • [7] Identification and assay of underivatized urinary acylcarnitines by paper spray tandem mass spectrometry
    Naccarato, Attilio
    Moretti, Sacha
    Sindona, Giovanni
    Tagarelli, Antonio
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (25) : 8267 - 8276
  • [8] Identification and assay of underivatized urinary acylcarnitines by paper spray tandem mass spectrometry
    Attilio Naccarato
    Sacha Moretti
    Giovanni Sindona
    Antonio Tagarelli
    Analytical and Bioanalytical Chemistry, 2013, 405 : 8267 - 8276
  • [9] Direct Analysis and Quantification of Metaldehyde in Water using Reactive Paper Spray Mass Spectrometry
    Simon Maher
    Fred P. M. Jjunju
    Deidre E. Damon
    Hannah Gorton
    Yosef S. Maher
    Safaraz U. Syed
    Ron M. A. Heeren
    Iain S. Young
    Stephen Taylor
    Abraham K. Badu-Tawiah
    Scientific Reports, 6
  • [10] Investigation of Reactions Between Isothiazolinones and Cysteamine by Reactive Paper Spray Ionization Mass Spectrometry (Reactive PSI MS)
    Choi, Soobin
    Cha, Sangwon
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2020, 41 (01): : 48 - 53