Improved depiction of small anatomic structures in MR images using Gaussian-weighted spirals and zero-filled interpolation

被引:7
作者
Elgavish, RA [1 ]
Twieg, DB [1 ]
机构
[1] Univ Alabama, Dept Biomed Engn, Birmingham, AL 35294 USA
关键词
partial-volume effect; zero-filled interpolation; Gibbs ringing; variable-density k-space sampling;
D O I
10.1016/S0730-725X(02)00642-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Partial-volume artifacts reduce the contrast and continuity of small structures in magnetic resonance images. Zero-filled interpolation (ZFI) has been known for some time as a useful technique to reduce partial-volume artifacts and improve the appearance of small structures and edges. However, its use is limited by the fact that ZFI can exacerbate image artifacts. For example, it can exacerbate Gibbs ringing, also known as the truncation artifact, which manifests itself as spurious ringing around sharp edges. Currently, the most common technique to address this problem is post-acquisition filtering, which causes blurring in the image. Using ZFI in conjunction with a variable-density sampling method designed to reduce ringing is proposed as a possible solution to this problem. This approach is demonstrated with a Gaussian-weighted spiral and is compared to conventional spiral sampling both with and without the application of a filter used to reduce ringing. The two spiral sampling techniques are compared using simulations, phantom images, and in vivo brain images. The Gaussian-weighted spiral demonstrates reduced ringing without the loss of spatial resolution commonly associated with post-acquisition filtering. Additionally, this sampling technique is shown to work well in conjunction with ZFI to reduce partial-volume artifacts without the apparent increase in Gibbs ringing usually associated with zero-filled reconstruction. This approach will be most useful for imaging techniques such as MR angiography which are known to be sensitive to partial-volume effects, as well as when imaging anatomic regions associated with more severe Gibbs ringing. (C) 2003 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:103 / 112
页数:10
相关论文
共 47 条
[1]  
Adalsteinsson E, 1999, MAGNET RESON MED, V42, P314, DOI 10.1002/(SICI)1522-2594(199908)42:2<314::AID-MRM14>3.0.CO
[2]  
2-X
[3]   A constrained Gauss-Seidel method for correction of point spread function effect in MR spectroscopic imaging [J].
Angelie, E ;
Sappey-Marinier, D ;
Mallet, J ;
Bonmartin, A ;
Sau, J .
MAGNETIC RESONANCE IMAGING, 2000, 18 (05) :625-633
[4]   FOURIER SPECTROSCOPY AND CAUSALITY PRINCIPLE [J].
BARTHOLD.E ;
ERNST, RR .
JOURNAL OF MAGNETIC RESONANCE, 1973, 11 (01) :9-19
[5]  
BRACEWELL RN, 1978, FOURIER TRANSFORM IT, P62
[6]   SYRINX-LIKE ARTIFACTS ON MR IMAGES OF THE SPINAL-CORD [J].
BRONSKILL, MJ ;
MCVEIGH, ER ;
KUCHARCZYK, W ;
HENKELMAN, RM .
RADIOLOGY, 1988, 166 (02) :485-488
[7]   DATA EXTRAPOLATION FOR TRUNCATION ARTIFACT REMOVAL [J].
CONSTABLE, RT ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (01) :108-118
[8]   CHARACTERISTIC FEATURES OF MR TRUNCATION ARTIFACTS [J].
CZERVIONKE, LF ;
CZERVIONKE, JM ;
DANIELS, DL ;
HAUGHTON, VM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (06) :1219-1228
[9]  
DANIELS DL, 1987, AM J NEURORADIOL, V8, P793
[10]   REDUCTION OF PARTIAL-VOLUME ARTIFACTS WITH ZERO-FILLED INTERPOLATION IN 3-DIMENSIONAL MR-ANGIOGRAPHY [J].
DU, YPP ;
PARKER, DL ;
DAVIS, WL ;
CAO, G .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05) :733-741