Development and validation of an LC-MS/MS method for the determination of quetiapine and four related metabolites in human plasma

被引:35
|
作者
Davis, Patricia C. [1 ]
Bravo, Orlando [2 ]
Gehrke, Mark [2 ]
Azumaya, Connie T. [1 ]
机构
[1] AstraZeneca Pharmaceut LP, Clin Pharmacol & DMPK Dept, Wilmington, DE 19850 USA
[2] Bioanalyt Syst Inc, W Lafayette, IN 47906 USA
关键词
Quetiapine; ICI204,636; Norquetiapine; Metabolites; LC-MS/MS; Psychotropics; EXTENDED-RELEASE FORMULATION; DOUBLE-BLIND; BIPOLAR MANIA; ACUTE SCHIZOPHRENIA; PLACEBO; MONOTHERAPY; EFFICACY; TOLERABILITY; FUMARATE; LITHIUM;
D O I
10.1016/j.jpba.2009.11.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pharmacokinetic measurement of the psychotropic compound quetiapine and four related metabolites in human plasma was conducted using a sensitive and specific liquid-chromatography tandem mass spectrometry (LC-MS/MS) assay that has been developed and validated for this purpose. The assay employs a single liquid-liquid extraction of quetiapine and its N-desalkyl (norquetiapine, M211,803, M1), 7-hydroxy (M214,227, M2),7-hydroxy N-desalkyl (M236,303, M3), and sulfoxide (M213,841, M4) metabolites from human plasma, and utilizes dual-column separation, using Luna C-18 columns (50 mm x 2.0 mm, 5 mu m) and positive ionization tandem MS detection in the multiple reaction monitoring (MRM) mode of the analytes and their respective stable labeled internal standards. The method provides a linear response from a quantitation range of < 0.70 ng/ml to at least 500 ng/ml for each analyte using 40 mu l of plasma. The applicable range was extended by dilution up to 100-fold with blank matrix. The accuracy and precision for quetiapine were less than 6.0% and 6.4% for quetiapine, respectively. The accuracy (and precision) was less than 9.4% (5.9%) for norquetiapine; 6.4% (6.2%) for M2; and 10.0% (6.4%) for M3; and 8.6% (9.5%) for M4. This methodology enabled the determination of the pharmacokinetics of quetiapine and its metabolites in human plasma, and an example of its application is presented. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1113 / 1119
页数:7
相关论文
共 50 条
  • [21] Development and validation of Lenalidomide in human plasma by LC-MS/MS
    Ranganathan, Premanand
    Gunasekaran, V
    Singhvi, Indrajeet
    Ansari, Mohammad Javed
    SAUDI JOURNAL OF BIOLOGICAL SCIENCES, 2019, 26 (07) : 1843 - 1847
  • [22] Development and Validation of an LC-MS/MS Method for the Quantitative Determination of Contezolid in Human Plasma and Cerebrospinal Fluid
    Zhang, Guanxuanzi
    Zhang, Na
    Dong, Liuhan
    Bai, Nan
    Cai, Yun
    PHARMACEUTICALS, 2023, 16 (01)
  • [23] Development and validation of an LC-MS/MS method for determination of compound K in human plasma and clinical application
    Kim, Jung Soo
    Kim, Yunjeong
    Han, Song-Hee
    Jeon, Ji-Young
    Hwang, Minho
    Im, Yong-Jin
    Kim, Jung Hyun
    Lee, Sun Young
    Chae, Soo-Wan
    Kim, Min-Gul
    JOURNAL OF GINSENG RESEARCH, 2013, 37 (01) : 135 - 141
  • [24] Development and validation of a sensitive LC-MS/MS method for the determination of D-serine in human plasma
    Xie, Y.
    Alexander, G. M.
    Schwartzman, R. J.
    Singh, N.
    Torjman, M. C.
    Goldberg, M. E.
    Wainer, I. W.
    Moaddel, R.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 89 : 1 - 5
  • [25] Development and validation of a sensitive LC-MS/MS method for the determination of fenoterol in human plasma and urine samples
    Sanghvi, M.
    Ramamoorthy, A.
    Strait, J.
    Wainer, I. W.
    Moaddel, R.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 933 : 37 - 43
  • [26] Development and Validation of an LC-MS/MS Method for the Simultaneous Quantification of Abiraterone, Enzalutamide, and Their Major Metabolites in Human Plasma
    van Nuland, Merel
    Hillebrand, M. J. X.
    Rosing, H.
    Schellens, J. H. M.
    Beijnen, J. H.
    THERAPEUTIC DRUG MONITORING, 2017, 39 (03) : 243 - 251
  • [27] Development and Validation of LC–MS/MS Method for Simultaneous Determination of Metformin and Four Gliptins in Human Plasma
    Mohammed Al Bratty
    Hassan A. Alhazmi
    Sadique Akhtar Javed
    Keddal G. Lalitha
    Mufarreh Asmari
    Jessica Wölker
    Sami El Deeb
    Chromatographia, 2017, 80 : 891 - 899
  • [28] LC-MS/MS method development and validation for the determination of polymyxins and vancomycin in rat plasma
    Cheng, Chang
    Liu, Shaorong
    Xiao, Deqing
    Hollembaek, John
    Yao, Lili
    Lin, Jing
    Hansel, Steven
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (28): : 2831 - 2838
  • [29] Development and validation of LC-MS/MS method for quantitative determination of (-)-securinine in mouse plasma
    Wabuyele, Simuli L.
    Wald, David
    Xu, Yan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 960 : 19 - 26
  • [30] Validation of a method for quantifying enzalutamide and its major metabolites in human plasma by LC-MS/MS
    O'Hare, Alice
    BIOANALYSIS, 2014, 6 (06) : 727 - 727