Development and validation of an LC-MS/MS method for the determination of quetiapine and four related metabolites in human plasma

被引:35
|
作者
Davis, Patricia C. [1 ]
Bravo, Orlando [2 ]
Gehrke, Mark [2 ]
Azumaya, Connie T. [1 ]
机构
[1] AstraZeneca Pharmaceut LP, Clin Pharmacol & DMPK Dept, Wilmington, DE 19850 USA
[2] Bioanalyt Syst Inc, W Lafayette, IN 47906 USA
关键词
Quetiapine; ICI204,636; Norquetiapine; Metabolites; LC-MS/MS; Psychotropics; EXTENDED-RELEASE FORMULATION; DOUBLE-BLIND; BIPOLAR MANIA; ACUTE SCHIZOPHRENIA; PLACEBO; MONOTHERAPY; EFFICACY; TOLERABILITY; FUMARATE; LITHIUM;
D O I
10.1016/j.jpba.2009.11.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pharmacokinetic measurement of the psychotropic compound quetiapine and four related metabolites in human plasma was conducted using a sensitive and specific liquid-chromatography tandem mass spectrometry (LC-MS/MS) assay that has been developed and validated for this purpose. The assay employs a single liquid-liquid extraction of quetiapine and its N-desalkyl (norquetiapine, M211,803, M1), 7-hydroxy (M214,227, M2),7-hydroxy N-desalkyl (M236,303, M3), and sulfoxide (M213,841, M4) metabolites from human plasma, and utilizes dual-column separation, using Luna C-18 columns (50 mm x 2.0 mm, 5 mu m) and positive ionization tandem MS detection in the multiple reaction monitoring (MRM) mode of the analytes and their respective stable labeled internal standards. The method provides a linear response from a quantitation range of < 0.70 ng/ml to at least 500 ng/ml for each analyte using 40 mu l of plasma. The applicable range was extended by dilution up to 100-fold with blank matrix. The accuracy and precision for quetiapine were less than 6.0% and 6.4% for quetiapine, respectively. The accuracy (and precision) was less than 9.4% (5.9%) for norquetiapine; 6.4% (6.2%) for M2; and 10.0% (6.4%) for M3; and 8.6% (9.5%) for M4. This methodology enabled the determination of the pharmacokinetics of quetiapine and its metabolites in human plasma, and an example of its application is presented. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1113 / 1119
页数:7
相关论文
共 50 条
  • [1] Development and validation of a sensitive and robust LC-MS/MS with electrospray ionization method for simultaneous quantitation of quetiapine and its active metabolite norquetiapine in human plasma
    Xiong, Xin
    Yang, Li
    Duan, Jingli
    CLINICA CHIMICA ACTA, 2013, 423 : 69 - 74
  • [2] Measurement of quetiapine and four quetiapine metabolites in human plasma by LC-MS/MS
    Fisher, Danielle S.
    Handley, Simon A.
    Taylor, David
    Flanagan, Robert J.
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (09) : 1125 - 1132
  • [3] Development and validation of a LC-MS/MS method for the determination of viaminate in human plasma
    Yin, Jing
    Ni, Kun-Yi
    Shen, Yue
    Ma, Peng-Cheng
    Cao, Ling
    Wang, Wei-Peng
    Wang, Yu
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 856 (1-2): : 376 - 380
  • [4] LC-MS/MS Method Development and Validation for the Determination of Nifedipine in Human Plasma
    Logoyda, Liliya S.
    BIOINTERFACE RESEARCH IN APPLIED CHEMISTRY, 2020, 10 (05): : 6220 - 6227
  • [5] Development and Validation of LC-MS/MS Method for Simultaneous Determination of Metformin and Four Gliptins in Human Plasma
    Al Bratty, Mohammed
    Alhazmi, Hassan A.
    Javed, Sadique Akhtar
    Lalitha, Keddal G.
    Asmari, Mufarreh
    Woelker, Jessica
    El Deeb, Sami
    CHROMATOGRAPHIA, 2017, 80 (06) : 891 - 899
  • [6] LC-MS/MS method for the determination of carbamathione in human plasma
    Heemskerk, Anthonius A. M.
    van Haandel, Leon
    Woods, Joshua M.
    McCance-Katz, Elinore F.
    Williams, Todd D.
    Stobaugh, John F.
    Faiman, Morris D.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (04) : 799 - 806
  • [7] Development and Validation of New LC-MS/MS Method for the Determination of armodafinil in Human Plasma
    Ramesh, Devi
    Ramakrishna, Singirikonda
    Habibuddin, Mohammad
    CURRENT PHARMACEUTICAL ANALYSIS, 2012, 8 (03) : 295 - 305
  • [8] Development and Validation of an LC-MS/MS Method for the Simultaneous Quantification of Abiraterone, Enzalutamide, and Their Major Metabolites in Human Plasma
    van Nuland, Merel
    Hillebrand, M. J. X.
    Rosing, H.
    Schellens, J. H. M.
    Beijnen, J. H.
    THERAPEUTIC DRUG MONITORING, 2017, 39 (03) : 243 - 251
  • [9] LC-MS/MS method for the determination of clodronate in human plasma
    Hasan, Mahmoud
    Schumacher, Gitta
    Seekamp, Anne
    Taedken, Tobias
    Siegmund, Werner
    Oswald, Stefan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 100 : 341 - 347
  • [10] Determination of Lisdexamfetamine in Human Plasma by LC-MS/MS Method
    Silva, Alex A. R.
    Coelho, Lilia L. D.
    Sanchez-Luquez, Karen Y.
    Garcia, Pedro H. D.
    Boldin, Renata
    Silveira, Anne M. R.
    Antonio, Marcia A.
    Porcari, Andreia M.
    Carvalho, Patricia O.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2025, 36 (04)