Temporally constrained reconstruction of dynamic cardiac perfusion MRI

被引:85
作者
Adluru, Ganesh
Awate, Suyash P.
Tasdizen, Tolga
Whitaker, Ross T.
DiBella, Edward V. R.
机构
[1] Univ Utah, Elect & Comp Engn Dept, Salt Lake City, UT 84112 USA
[2] Univ Utah, Sch Comp, Sci Comp & Imaging Inst, Salt Lake City, UT 84112 USA
[3] Univ Utah, Utah Ctr Adv Imaging Res, Dept Radiol, Salt Lake City, UT 84112 USA
[4] Univ Utah, Dept Bioengn, Salt Lake City, UT 84112 USA
关键词
dynamic contrast-enhanced MR; cardiac perfusion; regularization; regularization parameter; L-curve;
D O I
10.1002/mrm.21248
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dynamic contrast-enhanced (DCE) MRI is a powerful technique to probe an area of interest in the body. Here a temporally constrained reconstruction (TCR) technique that requires less k-space data over time to obtain good-quality reconstructed images is proposed. This approach can be used to improve the spatial or temporal resolution, or increase the coverage of the object of interest. The method jointly reconstructs the space-time data iteratively with a temporal constraint in order to resolve aliasing. The method was implemented and its feasibility tested on DCE myocardial perfusion data with little or no motion. The results obtained from sparse k-space data using the TCR method were compared with results obtained with a sliding-window (SW) method and from full data using the standard inverse Fourier transform (IFT) reconstruction. Acceleration factors of 5 (R = 5) were achieved without a significant loss in image quality. Mean improvements of 28 +/- 4% in the signal-to-noise ratio (SNR) and 14 4% in the contrast-to-noise ratio (CNR) were observed in the images reconstructed using the TCR method on sparse data (R = 5) compared to the standard IFT reconstructions from full data for the perfusion datasets. The method has the potential to improve dynamic myocardial perfusion imaging and also to reconstruct other sparse dynamic MR acquisitions.
引用
收藏
页码:1027 / 1036
页数:10
相关论文
共 28 条
[1]  
Awate Suyash P, 2006, Conf Proc IEEE Eng Med Biol Soc, V2006, P936
[2]   Application of reduced-encoding imaging with generalized-series reconstruction (RIGR) in dynamic MR imaging [J].
Chandra, S ;
Liang, ZP ;
Webb, A ;
Lee, H ;
Morris, HD ;
Lauterbur, PC .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (05) :783-797
[3]   BLOCK REGIONAL INTERPOLATION SCHEME FOR K-SPACE (BRISK) - A RAPID CARDIAC IMAGING TECHNIQUE [J].
DOYLE, M ;
WALSH, EG ;
BLACKWELL, GG ;
POHOST, GM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (02) :163-170
[4]   On the influence of training data quality in k-t BLAST reconstruction [J].
Hansen, MS ;
Kozerke, S ;
Pruessmann, KP ;
Boesiger, P ;
Pedersen, EM ;
Tsao, J .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (05) :1175-1183
[5]  
HANSEN PC, COMPUTATIONAL INVERS, P119
[6]   Fast dynamic imaging using two reference images [J].
Hanson, JM ;
Liang, ZP ;
Wiener, EC ;
Lauterbur, PC .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (01) :172-175
[7]   Accelerated 4D dobutamine stress MR imaging with k-t BLAST: Feasibility and diagnostic performance [J].
Jahnke, Cosima ;
Paetsch, Ingo ;
Gebker, Rolf ;
Bornstedt, Axel ;
Fleck, Eckart ;
Nagel, Eike .
RADIOLOGY, 2006, 241 (03) :718-728
[8]   K-SPACE SUBSTITUTION - A NOVEL DYNAMIC IMAGING TECHNIQUE [J].
JONES, RA ;
HARALDSETH, O ;
MULLER, TB ;
RINCK, PA ;
OKSENDAL, AN .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) :830-834
[9]  
Karniadakis G, 2003, PARALLEL SCI COMPUTI
[10]   Extended coverage first-pass perfusion imaging using slice-interleaved TSENSE [J].
Kellman, P ;
Derbyshire, JA ;
Agyeman, KO ;
McVeigh, ER ;
Arai, AE .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) :200-204