Assessing the Energy and Indoor Air Quality Performance for a Three-Story Building Using an Integrated Model, Part One: The Need for Integration

被引:0
|
作者
Heibati, Seyedmohammadreza [1 ]
Maref, Wahid [1 ]
Saber, Hamed H. [2 ]
机构
[1] Univ Quebec, Construct Engn Dept, ETS, Montreal, PQ H3C 1K3, Canada
[2] Jubail Univ Coll, Dept Mech Engn, Royal Commiss Jubail & Yanbu, Jubail Ind City 31961, Saudi Arabia
关键词
integrated simulation model; EnergyPlus; CONTAM; energy consumption; indoor air quality; heat; air and moisture transport; INFILTRATION RATES; VISUAL COMFORT; FLOW MODELS; SIMULATION; CONSUMPTION; EFFICIENCY; SAVINGS; DESIGN; SINGLE;
D O I
10.3390/en12244775
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In building applications, there is a dynamic interaction/coupling between the energy performance and the indoor air quality (IAQ) performance. Previously, the performance of energy consumption (EC) and IAQ has been evaluated independently. In this study, an energy performance model (EnergyPlus) and IAQ performance model (CONTAM: contaminant transport analysis) were simultaneously coupled as a new integrated simulation model in which the control variables were exchanged between the two models. Two scenarios were provided in this study for a three-story house. The first scenario addressed the effect of airtightness only. The second scenario, however, addressed the airtightness with an exhaust fan with an upgraded filter. In order to better analyze the accuracy of the simulations, the performance of the energy and IAQ were simulated independently using the EnergyPlus model and CONTAM model. Thereafter, the performance of the energy and IAQ were simulated using the present integrated simulation model. All simulations were conducted for the climatic conditions of Montreal and Miami. The results of the integrated simulation model showed that the exchange of control variables between both EnergyPlus and CONTAM produced accurate results for the performance of both energy and IAQ. Finally, the necessity of using the present integrated simulation model is discussed.
引用
收藏
页数:18
相关论文
共 14 条
  • [1] Assessing the Energy, Indoor Air Quality, and Moisture Performance for a Three-Story Building Using an Integrated Model, Part Three: Development of Integrated Model and Applications
    Heibati, Seyedmohammadreza
    Maref, Wahid
    Saber, Hamed H.
    ENERGIES, 2021, 14 (18)
  • [2] Assessing the Energy, Indoor Air Quality, and Moisture Performance for a Three-Story Building Using an Integrated Model, Part Two: Integrating the Indoor Air Quality, Moisture, and Thermal Comfort
    Heibati, Seyedmohammadreza
    Maref, Wahid
    Saber, Hamed H.
    ENERGIES, 2021, 14 (16)
  • [3] Commercial building retrofitting: Assessment of improvements in energy performance and indoor air quality
    Alazazmeh, Ayman
    Asif, Muhammad
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 26 (26)
  • [4] Seismic assessment of a three-story wood building with an integrated CLT-lightframe system using RTHS
    Nguyen, Tu T.
    Dao, Thang N.
    Aaleti, Sriram
    van de Lindt, John W.
    Fridley, Kenneth J.
    ENGINEERING STRUCTURES, 2018, 167 : 695 - 704
  • [5] A Health Performance Evaluation Model of Apartment Building Indoor Air Quality
    Zheng, Qi
    Lee, Donghoon
    Lee, Sungho
    Kim, Jeong Tai
    Kim, Sunkuk
    INDOOR AND BUILT ENVIRONMENT, 2011, 20 (01) : 26 - 35
  • [6] An integrated modeling tool for simultaneous analysis of thermal performance and indoor air quality in building
    Yan, D
    Song, FT
    Yang, XD
    Jiang, Y
    Zhao, B
    Zhang, XL
    Liu, XH
    Wang, XK
    Xu, FF
    Wu, P
    Gopal, V
    Dobbs, G
    Sahm, M
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2872 - 2876
  • [7] Monitoring building energy consumption, thermal performance, and indoor air quality in a cold climate region
    Sharmin, Tanzia
    Guel, Mustafa
    Li, Xinming
    Ganev, Veselin
    Nikolaidis, Ioanis
    Al-Hussein, Mohamed
    SUSTAINABLE CITIES AND SOCIETY, 2014, 13 : 57 - 68
  • [8] Using coupled energy, airflow and indoor air quality software (TRNSYS/CONTAM) to evaluate building ventilation strategies
    Dols, W. Stuart
    Emmerich, Steven J.
    Polidoro, Brian J.
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2016, 37 (02) : 163 - 175
  • [9] Energy performance of a lightweight opaque ventilated facade integrated with the HVAC system using saturated exhaust indoor air
    Cianfrini, Claudio
    Corcione, Massimo
    Habib, Emanuele
    Quintino, Alessandro
    ENERGY AND BUILDINGS, 2012, 50 : 26 - 34
  • [10] Indoor air quality and energy management in buildings using combined moving horizon estimation and model predictive control
    Ganesh, Hari S.
    Seo, Kyeongjun
    Fritz, Hagen E.
    Edgar, Thomas F.
    Novoselac, Atila
    Baldea, Michael
    JOURNAL OF BUILDING ENGINEERING, 2021, 33